Sequence 8 - Testing Procedures

Before you start this test, make sure that all knobs on the Sequence 8 
have been rotated fully counter clockwise and that all 3 toggle 
switches (Hold Hard, Clock Switch, Random) are in the down position.

—TESTING CV OUTPUTS—

When you first turn on the Sequence 8 it

 

should

 

be running on its 

internal clock. Let’s make sure that all 3 CV Outputs are working 
correctly. 

 

Begin by plugging in a cable into the Sequence 8’s CV 1 

Output and plug the other end of the cable into the 1V/Oct Input on an 
Oscillator, and make sure to monitor the output of the oscillator.
Since all 8 of the sequence knobs are rotated fully counter clockwise 
and the CV 1 input is set fully counter clockwise, you should get a 
stable tone out of your Oscillator. 

Rotate Step 1’s knob fully clockwise and leave the CV 1 attenuator set 
fully counter clockwise. You should still get a stable tone out of your 
Oscillator when it passes the voltage for Stage 1. If the Oscillator 
changes pitch even though the CV 1 Attenuator is turned down all the 

Summary of Contents for SEQUENCE 8

Page 1: ...le into the Sequence 8 s CV 1 Output and plug the other end of the cable into the 1V Oct Input on an Oscillator and make sure to monitor the output of the oscillator Since all 8 of the sequence knobs are rotated fully counter clockwise and the CV 1 input is set fully counter clockwise you should get a stable tone out of your Oscillator Rotate Step 1 s knob fully clockwise and leave the CV 1 attenu...

Page 2: ...ps 3 through 8 You should be able to confirm that all 8 steps can pass a minimum of 0 volts to a maximum of 5 volts and that all 3 CV Output Attenuators are working correctly Now Flip the HOLD HARD switch into the DOWN position TESTING CLOCK IN CLOCK OUT TESTING INTERNAL CLOCK Slowly rotate the RATE C Course knob until you notice the pattern going quite fast Now rotate the RATE F Fine knob from fu...

Page 3: ... UP position Slowly rotate the RNDRATE Random Rate knob clockwise until you will notice the via the LEDs on the front panel the sequence start to move around randomly This random behavior acts subtly at lower settings and will great faster as the knob is rotated clockwise NOTE This does not effect the CLOCK OUT Now flip the RANDOM switch to the DOWN position TESTING RESET While the Sequence 8 is r...

Page 4: ...ence 8 is working correctly If not go back through your soldering and double check your connections If you need more assistance utilize Synthroteks troubleshooting guide or reach out to us via our contact page and maybe we can point you in the right direction ...