Page 1: ...SUPERSERVER 6028R T 6028R TT SUPER USER S MANUAL 1 0 ...

Page 2: ...f any such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commerci...

Page 3: ...823TQ 653LPB chassis Chapter 2 Server Installation This chapter describes the steps necessary to install the SuperServer 6028R T TT into a rack and check out the server configuration prior to powering up the system Chapter 3 System Interface Refer here for details on the system interface which includes the functions and information provided by the control panel on the chassis as well as other LEDs...

Page 4: ...on the SC823TQ 653LPB server chassis You should follow the procedures given in this chapter when installing removing or reconfiguring SATA or peripheral drives and when replacing system power supply modules and cooling fans Chapter 7 BIOS The BIOS chapter includes an introduction to BIOS and provides detailed informa tion on running the CMOS Setup Utility Appendix A POST Error Beep Codes Appendix ...

Page 5: ...v Preface Notes ...

Page 6: ...Choosing a Setup Location 2 1 2 4 Warnings and Precautions 2 2 Rack Precautions 2 2 Server Precautions 2 2 Rack Mounting Considerations 2 3 Ambient Operating Temperature 2 3 Reduced Airflow 2 3 Mechanical Loading 2 3 Circuit Overloading 2 3 Reliable Ground 2 3 2 5 Installing the System into a Rack 2 4 Identifying the Sections of the Rack Rails 2 4 Installing the Chassis Rails 2 5 Installing the Ra...

Page 7: ... Handling 4 10 Redundant Power Supplies 4 12 Backplane Voltage 4 13 Comply with Local and National Electrical Codes 4 14 Product Disposal 4 15 Hot Swap Fan Warning 4 16 Power Cable and AC Adapter 4 18 Chapter 5 Advanced Serverboard Setup 5 1 Handling the Serverboard 5 1 Precautions 5 1 Unpacking 5 2 5 2 Connecting Cables 5 2 Connecting Data Cables 5 2 Connecting Power Cables 5 2 Connecting the Con...

Page 8: ... Precautions 6 1 6 2 Control Panel 6 3 6 3 System Fans 6 3 Replacing System Cooling Fans 6 3 6 4 Drive Bay Installation Removal 6 4 Accessing the Drive Bays 6 4 SATA Drive Installation 6 5 Installing a Component in the 5 25 Drive Bay 6 7 DVD ROM Drive Installation 6 8 Power Supply Failure 6 9 Chapter 7 BIOS 7 1 Introduction 7 1 Starting BIOS Setup Utility 7 1 How To Change the Configuration Data 7...

Page 9: ...ur 8 cm fans FAN 0126L4 Two passive CPU heatsinks SNK P0048PS One air shroud MCP 310 29016 0N SATA Accessories One SATA backplane BPN SAS 823TQ Six 3 5 hard drive carriers MCP 220 00092 0B One rackmount kit CSE PT25 Note For your system to work properly please follow the links below to download all necessary drivers utilities and the user s manual for your server Supermicro product manuals http ww...

Page 10: ...fer to Chapter 5 for details on installing memory SATA A SATA controller is integrated into the chipset to provide a ten port SATA 3 0 subsystem which is RAID 0 1 10 and 5 capable Six ports are supported by the Intel PCH I SATA0 5 I SATA 4 and 5 are colored yellow to indicate that they have embedded power to support SATA DOMs and four are supported by the Intel SCU S SATA0 3 PCI Expansion Slots Th...

Page 11: ... SC823T 653LPB chassis includes a single 650W high efficiency power supply Control Panel The control panel on the SC823T 653LPB provides important system monitoring and control information LEDs indicate power on network activity and hard disk drive activity Also present are a main power button and a system reset button Cooling Fans The chassis cooling design has been optimized to provide sufficien...

Page 12: ...00 BMC 3 2 5 RMII NCSI COM1 Connector COM2 Header VGA CONN BMC Boot Flash DDR3 SLOT 2 5 PHASE 145W P1 P1 P0 VR12 5 P0 1 4 1 3 1 2 QPI 9 6G SLOT 1 SLOT 3 PCI E X8 PCI E X16 G3 LAN REVERSE DMI2 PCI E X16 PCI E X8 G3 LAN REVERSE 1 5 1 6 PCI E X8 G3 LAN REVERSE 2 I M D 2 I M D SNB CORE DDR IV SNB CORE DDR IV QPI 9 6G 4GB s 5 PHASE 145W VR12 5 PCI E X8 3A X540 LAN PCI E X8 SLOT 4 SLOT 5 PCI E X16 PCI E...

Page 13: ...pe Address Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical Support rma supermicro nl Customer Support Web Site www supermicro nl Asia Pacific Address Super Micro Computer Inc 3F No 150 Jian 1st Rd Zhonghe Dist New Taipei City 235 Taiwan R O C Te...

Page 14: ...1 6 SUPERSERVER 6028R T TT User s Manual Notes ...

Page 15: ...ted in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electromagnetic fields are generated You will also need it placed near a grounded power outlet Read the Rack and Server Precautions in the next section 2 3 Preparing for Setup The box the SuperServer 6028R T TT was shipped in should include two sets of rail assemblies two rail mounting brackets and th...

Page 16: ...r Always make sure the rack is stable before extending a component from the rack You should extend only one component at a time extending two or more si multaneously may cause the rack to become unstable Server Precautions Review the electrical and general safety precautions in Chapter 4 Determine the placement of each component in the rack before you install the rails Install the heaviest server ...

Page 17: ...le overloading of circuits might have on overcurrent protection and power supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern Reliable Ground A reliable ground must be maintained at all times To ensure this the rack itself should be grounded Particular attention should be given to power supply connec tions other than the direct connect...

Page 18: ...Rails You should have received two rack rail assemblies with the SuperServer 6028R T TT Each of these assemblies consist of three sections an inner fixed chassis rail that secures to the 6028R T TT A and an outer fixed rack rail that secures directly to the rack itself B A sliding rail guide sandwiched between the two should remain attached to the fixed rack rail see Figure 2 1 The A and B rails m...

Page 19: ...the server into place when installed and pushed fully into the rack which is its normal position Secondly these tabs also lock the server in place when fully extended from the rack This prevents the server from coming completely out of the rack when you pull it out for servicing Figure 2 2 Installing Chassis Rails Installing the Rack Rails Determine where you want to place the SuperServer 6028R T ...

Page 20: ... with the front of the rack rails Slide the chassis rails into the rack rails keeping the pressure even on both sides you may have to depress the locking tabs when inserting See Figure 2 3 When the server has been pushed completely into the rack you should hear the locking tabs click Finish by inserting and tightening the thumbscrews that hold the front of the server to the rack Note figures are f...

Page 21: ...in the installation procedure will be the positioning of the rack brackets to the rack They should be spaced apart just enough to accommodate the width of the telco rack Note figures are for illustrative purposes only Servers should always be installed in racks from the bottom up Stability hazard The rack stabilizing mechanism must be in place or the rack must be bolted to the floor before you sli...

Page 22: ...2 8 SUPERSERVER 6028R T TT Manual Notes ...

Page 23: ... buttons on the chassis control panel 3 2 Control Panel Buttons There are two buttons located on the front of the chassis a reset button and a power on off button Reset Use the reset button to reboot the system Power This is the main power button which is used to apply or turn off the main system power Turning off system power with this button removes the main power but keeps standby power supplie...

Page 24: ...e activity when flashing 3 3 Control Panel LEDs The control panel located on the front of the SC823 chassis has five LEDs These LEDs provide you with critical information related to different parts of the system This section explains what each LED indicates when illuminated and any correc tive action you may need to take NIC2 Indicates network activity on LAN2 when flashing NIC1 Indicates network ...

Page 25: ...fy that the heatsinks are installed properly see Chapter 5 This LED will remain flashing or on as long as the indicated condition exists 3 4 Drive Carrier LEDs Each drive carrier has two LEDs Green When illuminated the green LED on the drive carrier indicates drive activity A connection to the SATA backplane enables this LED to blink on and off when that particular drive is being accessed Please r...

Page 26: ...SUPERSERVER 6028R T TT User s Manual 3 4 Notes ...

Page 27: ... configuring components in the Supermicro chassis These warnings may also be found on our web site at http www supermicro com about policies safety_information cfm Warning This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preve...

Page 28: ...el número que le ayudará a encontrar el texto traducido en el apartado de traducciones que acompaña a este dispositivo GUARDE ESTAS INSTRUCCIONES IMPORTANTES INFORMATIONS DE SÉCURITÉ Ce symbole d avertissement indique un danger Vous vous trouvez dans une situation pouvant entraîner des blessures ou des dommages corporels Avant de travailler sur un équipement soyez conscient des dangers liés aux ci...

Page 29: ... aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aan het eind van elke waarschuwing om deze te herleiden naar de desbetreffende locatie BEWAAR DEZE INSTRUCTIES ً ف اًك أى ٌوكي حالة ً ف تتسبب اصابة جسذٌة الزهز هذا ًٌ ٌع خطز ...

Page 30: ... instalación antes de conectar el sistema a la red de alimentación Attention Avant de brancher le système sur la source d alimentation consulter les directives d installation 設置手順書 システムを電源に接続する前に 設置手順書をお読み下さい ال إرشادات اقر تركيب توصيل قبل إلى النظام للطاقة مصدر לקרוא יש למקור המערכת חיבור לפני התקנה הוראות את מתח 시스템을 전원에 연결하기 전에 설치 안내를 읽어주십시오 Waarschuwing Raadpleeg de installatie instructies voo...

Page 31: ...liza el sistema de protección contra cortocircuitos o sobrecorrientes del edificio Asegúrese de que el dispositivo de protección no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit dépend de l installation électrique du local Vérifiez que le courant nominal du dispositif de protection n est pas supérieur à 250 V 20 A כי לוודא יש ...

Page 32: ...rd bevor es auf den Chassisinnenraum zurückgreift um Systemsbestandteile anzubringen oder zu entfernen Warning The system must be disconnected from all sources of power and the power cord removed from the power supply module s before accessing the chassis interior to install or remove system components 경고 이 제품은 전원의 단락 과전류 방지에 대해서 전적으로 건물의 관련 설비에 의존합니다 보호장치의 정격이 반드시 250V 볼트 20A 암페어 를 초과하지 않도록 해야 합니...

Page 33: ... ou enlever des composants de systéme חשמלי ניתוק מפני אזהרה אזהרה החשמל מקורות מכל המערכת את לנתק יש להסיר ויש מהספק החשמלי כבל את התקנ לצורך המארז של הפנימי לחלק גישה לפני ת הסר או ת רכיבים فصم يجب اننظاو جميع من مصادر انطاقت وإزانت انكهرباء سهك من وحدة امداد انطاقت قبم إنى انىصىل انداخهيت انمناطق ن ههيكم إزانت أو نتثبيج مكىناث الجهاز 경고 시스템에 부품들을 장착하거나 제거하기 위해서는 섀시 내부에 접근하기 전에 반드시 전원 공급장치로부터 연결...

Page 34: ... gestattet werden Advertencia Solamente el personal calificado debe instalar reemplazar o utilizar este equipo Attention Il est vivement recommandé de confier l installation le remplacement et la maintenance de ces équipements à des personnels qualifiés et expérimentés אזהרה רש בלבד מוסמך צוות את להחליף להתקין אי הציוד עבור שירות לתת או הציוד والمدربيه و لتزكيب استبدال أو خدمة الجهاس هذا يسمح أن ي...

Page 35: ... in Bereichen mit beschränktem Zutritt vorgesehen Der Zutritt zu derartigen Bereichen ist nur mit einem Spezialwerkzeug Schloss und Schlüssel oder einer sonstigen Sicherheitsvorkehrung möglich Advertencia Esta unidad ha sido diseñada para instalación en áreas de acceso restringido Sólo puede obtenerse acceso a una de estas áreas mediante la utilización de una herramienta especial cerradura con lla...

Page 36: ...رة تم انىص َمكن ً إن ىل منطقت محظورة فقط استخذاو خالل من خاصت أداة أو ٌ أ نال أخري وسُهت مألما ومفتاح قفم 경고 이 장치는 접근이 제한된 구역에 설치하도록 되어있습니다 특수도구 잠금 장치 및 키 또는 기타 보안 수단을 통해서만 접근 제한 구역에 들어갈 수 있습니다 Waarschuwing Dit apparaat is bedoeld voor installatie in gebieden met een beperkte toegang Toegang tot dergelijke gebieden kunnen alleen verkregen worden door gebruik te maken van speciaal gereedschap slot ...

Page 37: ...ipo o el equivalente recomendado por el fabricante Desechar las baterías gastadas según las instrucciones del fabricante אזהרה סכנת קיימת פיצוץ תקינה לא בדרך והוחלפה במידה הסוללה של להחליף יש בסוג הסוללה את מ התואם חברת מומל יצרן צת הסוללות סילוק המשומשות לבצע יש היצרן הוראות לפי خطر هناك من اسحبذال حالة في انفجار البطارية صحيحة غير بطريقة فعليل البطارية اسحبذال فقط النىع بنفس يعادلها ما أو مما أو...

Page 38: ...ette unité peut avoir plus d une connexion d alimentation Pour supprimer toute tension et tout courant électrique de l unité toutes les connexions d alimentation doivent être débranchées Redundant Power Supplies Warning This unit might have more than one power supply connection All connections must be removed to de energize the unit 冗長電源装置 このユニッ トは複数の電源装置が接続されている場合があります ユニッ トの電源を切るためには すべての接続を取り外さ...

Page 39: ...idado cuando lo revise Attention Lorsque le système est en fonctionnement des tensions électriques circulent sur le fond de panier Prendre des précautions lors de la maintenance Warning Hazardous voltage or energy is present on the backplane when the system is operating Use caution when servicing قد لهذا يكون ال جهاز اتصاالت عدة بوحدات الطاقة امداد إزالة يجب االتصاالت كافة لعسل ال وحدة عن الكهرباء...

Page 40: ...quipo debe cumplir con las normas de electricidad locales y nacionales هناك خطز مه الكهزبائي التيار على المىجىدة أوالطاقة اللىحة يكىن عندما النظام يعمل عند حذرا كه خدمة الجهاس هذا 경고 시스템이 동작 중일 때 후면판 Backplane 에는 위험한 전압이나 에너지가 발생 합니다 서비스 작업 시 주의하십시오 Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geboden tijdens het ...

Page 41: ...اويه والىطىية المحلية المتعلقة بالكهرباء Attention L équipement doit être installé conformément aux normes électriques nationales et locales 경고 현 지역 및 국가의 전기 규정에 따라 장비를 설치해야 합니다 Waarschuwing Bij installatie van de apparatuur moet worden voldaan aan de lokale en nationale elektriciteitsvoorschriften 製品の廃棄 この製品を廃棄処分する場合 国の関係する全ての法律 条例に従い処理する必要が あります 警告 本产品的废弃处理应根据所有国家的法律和规章进行 警告 本產品的廢棄處理應根據所有國家的法律和規...

Page 42: ...vironnement Renseignez vous auprès de l organisme compétent Warning The fans might still be turning when you remove the fan assembly from the chassis Keep fingers screwdrivers and other objects away from the openings in the fan assembly s housing Hot Swap Fan Warning המוצר סילוק אזהרה ו להנחיות בהתאם להיות חייב זה מוצר של סופי סילוק המדינה חוקי النهائي التخلص من المنتج هذا معه التعامل ينبغي ل وفقا...

Page 43: ...rde à ce que doigts tournevis et autres objets soient éloignés du logement du bloc ventilateur אזהרה חלקי את מסירים כאשר יש עובדים עדיין והמאווררים יתכן מהמארז המאוורר להרחיק ל המאוורר בתוך מהפתחים שונים עבודה וכלי האצבעות את בטוח מרחק انممكه مه انمراوح أن تسال ال إزانة تدورعند كتهة انمروحة انهيكم مه يجب إبقاء األصابع و انبراغي مفكات األشياء مه وغيرها بعيدا عه انفتحات في كتهة انمروحة 경고 섀시로부터 팬 조립...

Page 44: ...A auf der Code für alle anderen elektrischen Geräte als Produkte von Supermicro nur bezeichnet gezeigt haben Advertencia Al instalar el producto utilice los cables de conexión previstos o designados los cables y adaptadores de CA La utilización de otros cables y adaptadores podría ocasionar un mal funcionamiento o un incendio Aparatos Eléctricos y la Ley de Seguridad del Material prohíbe el uso de...

Page 45: ...צוין שלא تركيب عىذ استخذام يجب الجهاز و التىصيل كابالث الكهربائيت الكابالث ومحىالث المتردد التيار أن أي استخذام كابالث ومحىالث أخري يتسبب في عطل حذوث حريق أو التي لك تىفيرها تم المىتج مع UL أو CSA الكهربائيت األجهسة ومىاد قاوىن السالمت استخذام يحظر الكابالث قبل مه معتمذة Supermicro أجهسة أخري كهربائيت غير المىتجاث المعيىت قبل مه ألي UL CSA تحمل التي عالمت 경고 제품을 설치할 때에는 제공되거나 지정된 연결케이블과 전원케이블 AC어댑...

Page 46: ...4 20 SUPERSERVER 6028R T TT User s Manual Notes ...

Page 47: ...fully see previous chapter To prevent the serverboard from bending keep one hand under the center of the board to support it when handling The following measures are generally sufficient to protect your equipment from electric static discharge Precautions Use a grounded wrist strap designed to prevent Electrostatic Discharge ESD Touch a grounded metal object before removing any board from its anti...

Page 48: ... cables with their locations noted should be connected See the layout for connector locations SATA S SATA0 3 I SATA0 5 drive cables Control Panel cable JF1 Important Make sure the cables do not come into contact with the fans Connecting Power Cables The X10DRi X10DRi T has a 24 pin primary power supply connector J24 for con nection to the ATX power supply In addition there are two 8 pin 12V proces...

Page 49: ... Power Button OH Fan Fail PWR Fail LED 1 NIC1 Link LED Reset Button 2 Power Fail LED HDD LED FP PWRLED Reset PWR 3 3 V UID Switch UID LED Ground Ground 19 20 3 3V X Ground NMI X NIC2 Link LED NIC2 Activity LED NIC1 Activity LED These are Gb LAN ports on the X10DRi T and 10 Gb LAN ports on the X10DRi IO Ports 1 COM1 Port 6 USB Port 13 USB 3 0 2 USB Port 0 USB 2 0 7 LAN Port 1 3 USB Port 1 USB 2 0 8...

Page 50: ... re moving or changing any hardware components Make sure that you install the processor into the CPU socket before you install the CPU heatsink If you buy a CPU separately make sure that you use an Intel certified multi directional heatsink only Make sure to install the serverboard into the chassis before you install the CPU heatsinks When receiving a serverboard without a processor pre installed ...

Page 51: ... remove the WARNING plastic cap from the socket 5 Use your thumb and index finger to hold the CPU by its edges Align the CPU keys which are semi circle cutouts against the socket keys 6 Once they are aligned carefully lower the CPU straight down into the socket Do not drop the CPU on the socket Do not move the CPU horizontally or vertically and do not rub the CPU against any pins of the socket whi...

Page 52: ...load plate again and double check that the CPU is aligned properly 7 With the CPU in the socket in spect the four corners of the CPU to make sure that they are flush with the socket 8 Close the load plate Lock the lever labeled Close 1st then lock the lever labeled Open 1st Use your thumb to gently push the load levers down until the lever locks OPEN1st OPEN1st Lever Lock Push down and lock the le...

Page 53: ...r amount of thermal grease before you re install the heatsink Removing the Heatsink Caution We do not recommend removing the CPU or the heatsink If you do need to remove the heatsink please follow the instructions below to prevent damage to the CPU or other components Installing a CPU Heatsink 1 Place the heatsink on top of the CPU so that the four mounting holes are aligned with those on the rete...

Page 54: ...ith a maximum of 12 modules see the Memory Installation Table below 2 Insert each DIMM module vertically into its slot Pay attention to the notch along the bottom of the module to avoid installing incorrectly see Figure 5 3 3 Gently press down on the DIMM module until it snaps into place in the slot Repeat for all modules Warning Exercise extreme care when installing or removing DIMM modules to pr...

Page 55: ...mory pairs in P1 DIMMA2 P1 DIMMB2 P1 DIMMC2 P1 DIMMD2 slots 2 CPUs 4 DIMMs CPU1 CPU2 P1 DIMMA1 P1 DIMMB1 P2 DIMME1 P2 DIMMF1 2 CPUs 6 DIMMs CPU1 CPU2 P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 P2 DIMME1 P2 DIMMF1 2 CPUs 8 DIMMs CPU1 CPU2 P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 P2 DIMME1 P2 DIMMF1 P2 DIMMG1 P2 DIMMH1 2 CPUs 8 16 DIMMs CPU1 CPU2 P1 DIMMA1 P1 DIMMB1 P1 DIMMC1 P1 DIMMD1 P2 DIMME1 P2 DIMM...

Page 56: ...ed into the system PCI Card Installation Before installing a PCI add on card make sure it is supported by the slot you are installing it to 1 Begin by releasing the locking tab that corresponds to the slot you wish to populate 2 Insert the expansion card into the slot by pushing down with your thumbs evenly on both sides of the card ...

Page 57: ...X8 CPU2 SLOT6 PCI E 3 0 X16 P1 DIMMC2 P1 DIMMC1 P2 DIMME1 P2 DIMME2 P1 DIMMD1 P1 DIMMD2 P2 DIMMF1 P2 DIMMF2 VGA P1 DIMMB2 P2 DIMMH2 P1 DIMMA1 P1 DIMMA2 P2 DIMMG1 P2 DIMMH1 P2 DIMMG2 LAN2 COM1 LAN1 USB0 1 LE1 Fan6 LEDM1 BIOS JD1 JBR1 USB4 5 USB6 3 0 I SATA2 FANA JPG1 JPLAN1 JF1 P1 DIMMB1 FPCTRL Battery X10DRi T Rev 1 01 Intel PCH LAN CTRL BMC BMC FW J24 VGA BMC Memory USB12 13 USB 2 0 2 0 USB2 0 US...

Page 58: ... 6 FanA B CPU System Fan Headers J24 24 pin ATX Main Power Connector JD1 Speaker Power LED JF1 Front Panel Control Header JIPMB1 4 pin External BMC I2 C Header for an IPMI Card JL1 Chassis Intrusion Header JOH1 Overheat LED Indicator JPI2 C1 Power Supply SMBbus I2 C Header JPWR1 2 12V 8 Pin Power Connectors JSD1 JSD2 SATA DOM Device on Module Power Connectors JSTBY1 Standby Power Connector JTPM1 T...

Page 59: ...s 0 1 BP USB 12 13 Backpanel USB 2 0 Ports 12 13 or USB 3 0 Ports 0 1 FP USB 2 3 4 5 Front Accessible USB 2 0 Connection Headers 2 3 4 5 FP USB Type A Front Panel Accessible Type A Connector USB 3 0 Port 6 or USB 2 0 Port 10 J USB3 1 Front Panel Accessible USB 3 0 Ports 3 4 USB 2 0 8 9 LED Description State Status LE1 Rear UID LED Solid Blue Unit Identified LE2 Onboard PWR LED On System Power On L...

Page 60: ...er 24 pin Connector Pin Definitions Pin Definition Pin Definition 13 3 3V 1 3 3V 14 12V 2 3 3V 15 COM 3 COM 16 PS_ON 4 5V 17 COM 5 COM 18 COM 6 5V 19 COM 7 COM 20 Res NC 8 PWR_OK 21 5V 9 5VSB 22 5V 10 12V 23 5V 11 12V 24 COM 12 3 3V Reset Button Pin Definitions JF1 Pin Definition 3 Reset 4 Ground Power Button Pin Definitions JF1 Pin Definition 1 Power Signal 2 Ground Secondary Power Connector JPWR...

Page 61: ...nd 12 of JF1 Attach an LED cable to display network activity See the table on the right for pin definitions Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1 Refer to the table on the right for pin defini tions PWR Fail LED Pin Definitions JF1 Pin Definition 5 3 3V 6 Ground Overheat OH Fan Fail PWR Fail UID LED Connect an LED cable to pins 7 and 8 of Front Control Pane...

Page 62: ...e the table on the right for pin definitions T SGPIO Pin Definitions Pin Definition Pin Definition 1 NC 2 NC 3 Ground 4 Data 5 Load 6 Ground 7 Clock 8 NC NC No Connection Chassis Intrusion The Chassis Intrusion header is des ignated JL1 Attach an appropriate cable from the chassis to inform you of a chassis intrusion when the chas sis is opened Chassis Intrusion Pin Definitions Pin Definition 1 In...

Page 63: ...Header A Trusted Platform Module Port 80 header is located at JTPM1 to provide TPM support and Port 80 connection Use this header to enhance system performance and data security See the table on the right for pin definitions TPM Port 80 Header Pin Definitions Pin Definition Pin Definition 1 LCLK 2 GND 3 LFRAME 4 KEY 5 LRESET 6 5V X 7 LAD 3 8 LAD 2 9 3 3V 10 LAD1 11 LAD0 12 GND 13 SMB_CLK4 14 SMB_D...

Page 64: ... IPMB A System Management Bus header for IPMI 2 0 is located at JIPMB1 Connect the appropriate cable here to use the IPMB I2 C connection on your system IPMB Header Pin Definitions Pin Definition 1 Data 2 Ground 3 Clock 4 No Connection Power LED Speaker Pins 1 3 of JD1 are used for power LED indication and pins 4 7 are for the speaker See the tables on the right for pin definitions Please note tha...

Page 65: ...ocated on the rear I O panel COM2 located next to PCI E Slot1 is used to provide front access sup port See the table on the right for pin definitions Serial COM Port Pin Definitions Pin Definition Pin Definition 1 DCD 6 DSR 2 RXD 7 RTS 3 TXD 8 CTS 4 DTR 9 RI 5 Ground 10 N A LAN Ports Pin Definitions Pin Definition 1 P2V5SB 10 SGND 2 TD0 11 Act LED 3 TD0 12 P3V3SB 4 TD1 13 Link 100 LED Yel low 3V3S...

Page 66: ...D Indicator A Unit Identifier UID switch and an LED indicator are provided on the motherboard The rear UID switch is located next to the VGA port on the backplane The front UID switch is located on pin 13 of the JF1 header The rear UID LED LE1 is located next to the UID switch and the front UID LED is located on pin 7 on JF1 When you press the UID switch the UID LED will be turned on Press the UID...

Page 67: ...bled LAN1 2 Enable Disable Jumper Settings Jumper Setting Definition Pins 1 2 Enabled default Pins 2 3 Disabled VGA Enable Disable JPG1 allows you to enable or disable the VGA port The default position is on pins 1 and 2 to enable VGA See the table on the right for jumper settings VGA Enable Disable Jumper Settings Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled Watch Dog Enable Disab...

Page 68: ... jumper settings BMC Enable Jumper Settings Jumper Setting Definition Pins 1 2 BMC Enabled Pins 2 3 Disabled Manufacturer Mode Select Close pins 2 and 3 of jumper JPME2 to bypass SPI flash security and force the system to operate in the Manufac turer Mode which allows the user to flash the system firmware from a host server for system setting modifications See the table on the right for jumper set...

Page 69: ...ponents See the table on the right for more details IPMI Dedicated LAN LEDs An additional Dedicated IPMI LAN is also located on the I O backplane The amber LED on the right indicates activity while the green LED on the left indicates the speed of the connec tion See the table at right for more information IPMI LAN Link LED Left Activity LED Right LED Status Definition Link Left Green Solid 100 Mb ...

Page 70: ...ion 1 Ground 2 TXP 3 TXN 4 Ground 5 RXN 6 RXP 7 Ground SATA 3 0 Ports There are ten Serial ATA Ports which include six SATA supported by the PCH C612 I SATA0 5 and four SATA supported by the Intel SCU S SATA0 3 See the table on the right for pin definitions The system supports a total of six 3 5 hot swap hard drives ...

Page 71: ...ww supermicro com products Find the product page for your motherboard here where you may down load individual drivers and utilities After creating a CD DVD with the ISO files insert the disk into the CD DVD drive on your system and the display shown in Figure 5 5 should appear Note Click the icons showing a hand writing on paper to view the readme files for each item Click the computer icons to th...

Page 72: ...gement versions and can be used with Nagios to maximize your system monitoring needs With SuperDoctor 5 Man agement Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SD5 Manage ment Server monitors HTTP FTP and SMTP services to optimize the efficiency of your operation Note The default User Name and Password for Supe...

Page 73: ...ll Please comply with the regulations set up by your local hazardous waste management agency to dispose of your used battery properly 5 13 Onboard Battery Please handle used batteries carefully Do not damage the battery in any way a damaged battery may release hazardous materials into the environment Do not discard a used battery in the garbage or a public landfill Please comply with the regulatio...

Page 74: ...5 28 SUPERSERVER 6028R T 6028R TT User s Manual Notes ...

Page 75: ...To prevent damage to any printed circuit boards PCBs it is important to handle them very carefully The following measures are generally sufficient to protect your equipment from ESD damage Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal object before removing any board from its antistatic bag Handle a board by its edges only do not touch its compo...

Page 76: ...iews IO Panel see Figure 5 3 Low Profile PCI Slots Control Panel SATA Drives 6 5 25 Drive Bay DVD ROM Drive optional Unpacking The serverboard is shipped in antistatic packaging to avoid static damage When unpacking the board make sure the person handling it is static protected ...

Page 77: ... air to circulate properly through the chassis and cool the components See Figure 6 2 System Fan Failure Fan speed is controlled by system temperature via IPMI If a fan fails the remaining fan will ramp up to full speed and the overheat fan fail LED on the control panel will turn on Replace the failed fan at your earliest convenience with the same type and model the system can continue to run with...

Page 78: ... system For installing removing the DVD ROM you will need to gain access to the inside of the server by removing the top cover of the chassis Proceed to the DVD ROM Installation section later in this chapter for instructions For installing removing a component in the 5 25 drive bay proceed to the 5 25 Drive Bay Installation section later in this chapter for instructions 4 If the system is already ...

Page 79: ...vers For information on recommended HDDs visit the Supermicro Web site at http www supermicro com products nfo files storage SAS 1 CompList 110909 pdf SATA Drive Installation The SATA drives are mounted in drive carriers to simplify their installation and removal from the chassis Since these carriers also help promote proper airflow for the drive bays even empty carriers without drives installed m...

Page 80: ...tton on the drive carrier 2 Swing the handle fully out and use it to pull the drive carrier straight out see Figure 6 4 Note Your operating system must have RAID support to enable the hot plug ca pability of the drives Caution All of the SATA drive carriers must remain in the drive bay to maintain proper cooling airflow Release Button ...

Page 81: ...power must be turned off before installing and or removing them Installing Removing a 5 25 Drive Bay Component 1 First power down the system and then remove the top cover of the chassis 2 Push the locking latch to the right then remove the drive carrier from the chassis 3 Attach the component to the carrier if installing 4 Push the tray with the drive back into its bay in the chassis 5 Replace the...

Page 82: ...d click into place to be correctly and fully installed in their bays You must power down the system before installing or removing a DVD ROM drive 1 Release the screws that secure the server unit to the rack 2 Grasp the two handles on either side and pull the unit straight out until it locks you will hear a click 3 Depress the two buttons on the top of the chassis to release the top cover and at th...

Page 83: ...iled power supply module with the same model which can be ordered directly from Supermicro see Contact Information in the Preface 1 First shut down the system then unplug the AC power cord from the power supply module 2 Remove the chassis cover by pressing the two release buttons on the top of the chassis near the front then push the chassis top rearward about one inch and lift it off 3 To remove ...

Page 84: ...6 10 SUPERSERVER 6028R T TT User s Manual Notes ...

Page 85: ...hat can be configured Grayed out options cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in the left frame it is highlighted in white Often a text message will accompany it Note the AMI BIOS has default text messages built in Supermicro retains the optio...

Page 86: ... not upgrade the BIOS unless your system has a BIOS related issue Flashing the wrong BIOS can cause irreparable damage to the system In no event shall Supermicro be liable for direct indirect special incidental or consequential dam ages arising from a BIOS update If you have to update the BIOS do not shut down or reset the system while the BIOS is updating This is to avoid possible boot failure 7 ...

Page 87: ...y MM DD YYYY format The time is entered in HH MM SS format Note The time is in the 24 hour format For example 5 30 P M appears as 17 30 00 Supermicro X10DRi Version This item displays the version of the BIOS ROM used in the system Build Date This item displays the date when the version of the BIOS ROM used in the system was built Memory Information Total Memory This item displays the total size of...

Page 88: ...t Boot Use this feature to select the screen display between POST messages or the OEM logo at bootup Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST messages The options are Enabled and Disabled AddOn ROM Display Mode Use this item to set the display mode for the Option ROM Select Keep Current to use the current AddOn ROM display setti...

Page 89: ... the BIOS to automatically reboot the system from a Legacy boot device after its initial boot failure The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function Select Enabled to allow the Watch Dog timer to reboot the system when it is inac tive for more than 5 minutes The options are Enabled and Disabled Power Button Function This feature controls how the system shu...

Page 90: ...rt specified by the user The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto IOU1 II0 PCIe Port 3 This item configures the PCI E port Bifuraction setting for a PCI E port specified by the user The options are x4x4x4x4 x4x4x8 x8x4x4 x8x8 x16 and Auto No PCIe Port Active ECO Use this feature to select a workaround setting to implement the engineering change order ECO on the system when the PCI ...

Page 91: ... to force non fatal error prorogation to the II0 core error logic for the port specified by the user The options are Disable and Enable Corr Err Correctable Error Over Select Enable to force correctable error prorogation to the II0 core error logic for the port specified by the user The options are Disable and Enable L0s Support When this item is set to Disable II0 will not put its transmitter in ...

Page 92: ...ons to violate the strict ordering rules of PCI and to be completed prior to other transactions that have already been enqueued The options are Disable and Enable Intel VT for Directed I O VT d Intel VT for Direct I O VT d Intel VT for Directed I O VT d Select Enable to use Intel Virtualization Technology support for Direct I O VT d support by reporting the I O device assignments to the VMM Virtua...

Page 93: ...ase Limit QPI PCI E Configuration Base Siz Size Link Speed Mode Use this feature to select data transfer speed for QPI Link connections The op tions are Fast and Slow Link Frequency Select Use this feature to select the desired QPI frequency The options are 6 4 GT s 8 0 GT s 9 6 GT s Auto and Auto Limited Link L0p Enable Select Enable to enable Link L0p The options are Disable and Enable Link L1 E...

Page 94: ... are Auto Disabled and Enabled Enable ADR Select Enabled for ADR Automatic Diagnostic Repository support to enhance memory performance The options are Enabled and Disabled DRAM RAPL Running Average Power Limit Baseline Use this feature to set the run time power limit baseline for DRAM modules The options are Disable DRAM RAPL Mode 0 and DRAM RAPL Mode 1 Set Throttling Mode Throttling improves reli...

Page 95: ...selected the motherboard maintains two identical copies of all data in memory for data backup When Lockstep is selected the motherboard uses two areas of memory to run the same set of operations in parallel to boost performance The options are Disable Mirror and Lockstep Mode Lockstep x4 DIMMs Select Enable to enable Lockstep support for x4 DIMM modules The options are Auto Disabled and Enabled Me...

Page 96: ...mory turns out to be a correctable error the error is corrected and sent to the requestor the original source Memory is updated as well Select Enable to use Demand Scrubbing for ECC memory correction The options are Enable and Disable Device Tagging Select Enable to support device tagging The options are Disable and Enable South Bridge Configuration The following South Bridge information will disp...

Page 97: ...turn will provide complete legacy USB keyboard support for the operating systems that do not sup port legacy USB devices The options are Disabled and Enabled USB Transfer Time outs USB Transfer Time out This feature is used to set the USB time out value so that the tasks of USB control bulk and interrupt transfer can be performed during the time out period The settings are 1 second 5 seconds 10 se...

Page 98: ... is set to Enabled the SATA AHCI controller manages the power usage of the SATA link The controller will put the link to a low power state when the I O is inactive for an extended period of time and the power state will return to normal when the I O becomes active The options are Enabled and Disabled SATA Port 0 Port 5 This item displays the information detected on the installed SATA drive on the ...

Page 99: ...bove Configure SATA as is set to RAID the following items will display Support Aggressive Link Power Management When this item is set to Enabled the SATA AHCI controller manages the power usage of the SATA link The controller will put the link to a low power state when the I O is inactive for an extended period of time and the power state will return to normal when the I O becomes active The optio...

Page 100: ...he following items sSATA Controller This item enables or disables the onboard SATA controller supported by the Intel PCH sSATA controller The options are Enabled and Disabled Configure sSATA as Select IDE to configure an sSATA drive specified by the user as an IDE drive Select AHCI to configure an sSATA drive specified by the user as an AHCI drive Select RAID to configure an sSATA drive specified ...

Page 101: ...isk Drive The options are Hard Disk Drive and Solid State Drive If the item above Configure sSATA as is set to IDE the following items will display sSATA Port 0 Port 3 This item indicates that an sSATA port specified by the user is not installed or not detected Port 0 Port 3 sSATA Device Type Available when a SATA port is detected Use this item to specify if the sSATA port specified by the user sh...

Page 102: ...Set this item to Enabled for hot plugging support which will allow the user to replace an sSATA drive without shutting down the system The options are Enabled and Disabled sSATA Port 0 Port 3 Spin Up Device On an edge detect from 0 to 1 set this item to allow the PCH to start a COMRE SET initialization to the device The options are Enabled and Disabled Port 0 Port 3 sSATA Device Type Use this item...

Page 103: ...nfigure the PCI latency timer for a device installed on a PCI bus Select 32 to set the PCI latency timer to 32 PCI clock cycles The options are 32 64 96 128 160 192 224 and 248 PCI Bus Clocks VGA Palette Snoop Select Enabled to support VGA palette register snooping which will allow a PCI card that does not contain its own VGA color palette to examine a video card pal ette and mimic it for proper c...

Page 104: ...48 Bytes and 4096 Bytes ASPM Support Use this item to set the Active State Power Management ASPM level for a PCI E device Select Auto for the system BIOS to automatically set the ASPM level based on the system configuration Select Disabled to disable ASPM support The options are Disabled Auto and Force L0s Warning Enabling ASPM support may cause some PCI E devices to fail MMIOHBase Use this item t...

Page 105: ... IO Configuration Super IO Chip AST2400 Serial Port 1 Configuration Serial Port 2 Configuration Serial Port 1 Serial Port 2 Select Enabled to enable the onboard serial port specified by the user The options are Enabled and Disabled Device Settings This item displays the base I O port address and the Interrupt Request address of a serial port specified by the user Change Port 1 Settings Change Port...

Page 106: ...direction Select VT100 to use the ASCII Character set Select VT100 to add color and function key support Select ANSI to use the Extended ASCII Char acter Set Select VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are ANSI VT100 VT100 and VT UTF8 Bits Per second Use this item to set the transmission speed for a serial port used in Console Redirection Make s...

Page 107: ...TF8 Combination Key support for ANSI VT100 terminals The options are Enabled and Disabled Recorder Mode Select Enabled to capture the data displayed on a terminal and send it as text messages to a remote server The options are Disabled and Enabled Resolution 100x31 Select Enabled for extended terminal resolution support The options are Dis abled and Enabled Legacy OS Redirection Resolution Use thi...

Page 108: ...t used in Console Redirection Make sure that the same speed is used in the host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 38400 57600 and 115200 bits per second Data Bits Use this feature to set the data transmission size for Console Redirection The options are 7 Bits and 8 Bits Parity A parity bit can be sent alo...

Page 109: ... to select the number of rows and columns used in Console Redirection for legacy OS support The options are 80x24 and 80x25 Putty KeyPad This feature selects Function Keys and KeyPad settings for Putty which is a terminal emulator designed for the Windows OS The options are VT100 LINUX XTERMR6 SCO ESCN and VT400 Redirection After BIOS Post Use this feature to enable or disable legacy Console Redir...

Page 110: ...elect VT UTF8 to use UTF8 encoding to map Unicode characters into one or more bytes The options are ANSI VT100 VT100 and VT UTF8 Bits Per Second This item sets the transmission speed for a serial port used in Console Redirec tion Make sure that the same speed is used in both host computer and the client computer A lower transmission speed may be required for long and busy lines The options are 960...

Page 111: ...te Select Enabled to use TPM Trusted Platform Module settings to enhance system data security Please reboot your system for any change on the TPM state to take effect The options are Disabled and Enabled Pending Operation Use this item to schedule a TPM related operation to be performed by a security device for system data integrity Your system will reboot to carry out a pending TPM operation The ...

Page 112: ...ices such as an x86 RDTSC Instruc tion embedded in the CPU The High Performance Event Timer is used to replace the 8254 Programmable Interval Timer The options are Enabled and Disabled NUMA Support Available when the OS supports this feature Select Enabled to enable Non Uniform Memory Access support to enhance system performance The options are Enabled and Disabled COD Enable Available when the OS...

Page 113: ... Error Logging Support Select Enabled to support Runtime Error Logging The options are Enabled and Disabled If this item is set to Enable the following item will be available for con figuration Memory Corrected Error Enabling Available when the item above Runtime Error Logging Support is set to Enable Select Enabled for the BIOS to correct a memory error if it is correctable The op tions are Enabl...

Page 114: ... Immediately SMBIOS Event Log Standard Settings Log System Boot Event Select Enabled to log system boot events The options are Disabled and Enabled MECI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This item is used to determine how long in minutes should the mu...

Page 115: ...ur system System Event Log Enabling Disabling Options SEL Components Select Enabled to enable all system event logging support at bootup The options are Enabled and Disabled Erasing Settings Erase SEL Select Yes On next reset to erase all system event logs upon next system reboot Select Yes On every reset to erase all system event logs upon each system reboot Select No to keep all system event log...

Page 116: ...The following items will be displayed LAN Channel 1 Configuration Address Source Use this item to select the IP address source for this computer If Static is selected you will need to know the IP address of this computer and enter it to the system manually in the field If DHCP is selected AMI BIOS will search for a DHCP Dy namic Host Configuration Protocol server attached to the network and reques...

Page 117: ...teway IP Address This item displays the Gateway IP address for this computer This should be in decimal and in dotted quad form i e 192 168 10 253 Router MAC Address This item displays the Router MAC address for this computer ...

Page 118: ...ity The length of the password should be from 3 characters to 20 characters long User Password Use this feature to set the user password which is required to enter the BIOS setup utility The length of the password should be from 3 characters to 20 char acters long Password Check Select Setup for the system to prompt for a password at Setup Select Always for the system to prompt for a password at b...

Page 119: ... Legacy UEFI and Dual The default setting is Dual Fixed Boot Order Priorities This option prioritizes the order of bootable devices that the system to boot from Press Enter on each entry from top to bottom to select devices Dual Boot Order 1 Dual Boot Order 2 Dual Boot Order 3 Dual Boot Order 4 Dual Boot Order 5 Dual Boot Order 6 Dual Boot Order 7 Dual Boot Order 8 Dual Boot Order 9 ...

Page 120: ... new boot option is added to The format for the path is fsx path filename efi Boot Option File Path Create After the driver option name and the file path are set press Enter to enter to submenu and click OK to create the new boot option drive Delete Boot Option Use this item to select a boot device to delete from the boot priority list Delete Boot Option Select the target boot device to delete Del...

Page 121: ...s and Reset When you have completed the system configuration changes select this option to leave the BIOS setup utility and reboot the computer for the new system configura tion parameters can take effect Select Save Changes and Exit from the Exit menu and press Enter Save Options Save Changes When you have completed the system configuration changes select this option to save all changes made This...

Page 122: ...r Defaults from the Exit menu and press En ter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults from the Exit menu and press En ter Use this feature to retrieve user defined settings that were saved previously Boot Override This feature allows the user to override the Boot priorities sequence in the Bo...

Page 123: ...se fatal errors are usually communicated through a series of audible beeps The numbers on the fatal error list correspond to the number of beeps for the cor responding error Motherboard BIOS Error Beep Codes Beep Code LED Error Message Description 1 beep Refresh Ready to boot 5 short beeps 1 long beep Memory error No memory detected in the system 5 beeps No Con In or No Con Out devices Con In incl...

Page 124: ...A 2 SUPERSERVER 6028R T TT User s Manual Notes ...

Page 125: ...our web site for a complete listing of supported processors Chipset Intel C612 chipset BIOS 16 Mb AMI SPI Flash ROM Memory Capacity Sixteen DIMM Slots supporting up to 1 TB of ECC registered unbuffered DDR4 2133 1866 1333 1600 memory Note See Section 5 5 for details SATA Intel chipset based SATA controller for 10 SATA 3 0 ports SATA Drive Bays Six hot swap drive bays to house 3 5 SATA hard drives ...

Page 126: ...ment Operating Temperature 10º to 35º C 40º to 95º F Non operating Temperature 40º to 60º C 40º to 140º F Operating Relative Humidity 8 to 90 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022 Class A EN 61000 3 2 3 3 CISPR 22 Class A Electromagnetic Immunity EN 55024 CISPR 24 EN 61000 4 2 EN 61000 4 3 EN 61000...

Page 127: ...l such products for use in such ultra hazardous applications it does so entirely at its own risk Furthermore buyer agrees to fully indemnify defend and hold Supermicro harmless for and against any and all claims demands actions litigation and proceedings of any kind arising out of or related to such ultra hazardous use or sale Dioxide Lithium coin cells Perchlorate Material special handling may ap...

Page 128: ...B 4 SUPERSERVER 6028R T TT User s Manual Notes ...