BIONET

QUICK INSTALATION GUIDE

Electrolysis

RCA flow detector
pH probe
Redox probe

Ioniser Cu/Ag

Mains connection 220v.
3.15A fuse
250 mA fuse
On-off switch
Air vent
Acid pump connection

1

2

3

4

5

6

7

8

9

10

11

DESCRIPTION

1

Electrode housing

Ionization housing (2/4/6 e)
Copper/silver electrodes
Electrode bolt
Electrode cable

1

2

3

4

Cell

Electrolysis cell
RCA flow detector
Cell connector
Flow/gas detector

1

2

3

Optional extras

pH Probe

Concentric seal
Gasket

5

6

Conductividad Probe

Redox Probe

Cell housing

Probe
Probe casing
Connection housing

1

2

3

Probe
Probe casing
Connection housing

1

2

3

Probe
Probe casing
Connection housing

1

2

3

1

2

3

1

2

3

1

2

3

1

3

3

2

4

5

6

10

7

8

9

6

1

2

3

4

5

11

10

1

4

5

2

3

5

4

The salt water electrolysis produces Chlorine on the bases of salt water of low salinity (approximately 5g Salt per litre). As the 
swimming pool water containing the salt flows through the electrolysis cell, the salt is converted to Sodium-hypo-chloride (liquid 
chlorine). Organic mater present in the water is oxidised and eliminated by the chlorine. The Sodium-hypo-chloride reconverts into 
salt on its way back to the swimming pool.
This  process  is  combined  with  a  Copper  Silver  ionisation  which  provides  us  with  a  constant  flocculation  and  an  additional 
disinfectant, eliminating bacteria and algae. The result is exceptional clear and transparent Water.

Electronic unit

Summary of Contents for BIONET

Page 1: ...ing 1 2 3 Probe Probe casing Connection housing 1 2 3 1 2 3 1 2 3 1 2 3 1 3 3 2 4 5 6 10 7 8 9 6 1 2 3 4 5 11 10 1 4 5 2 3 5 4 The salt water electrolysis produces Chlorine on the bases of salt water of low salinity approximately 5g Salt per litre As the swimming pool water containing the salt flows through the electrolysis cell the salt is converted to Sodium hypo chloride liquid chlorine Organic...

Page 2: ...when water circulation has stopped TITANIUM CELLconnection overheating Ensure all electrical connections are firmly fixed to avoid false contacts and subsequent overheating of system components Especially concerning the electrolysis cell with usage above 33A 10A 10A 16A 16A 25A A B C 1 2 3 4 5 6 15 13 12 11 10 9 8 min 1m 330W 10A Chlorine pump Optional for models with redox or free chlorine contro...

Page 3: ...ERVALPROGRAMMER The system is programmed to ionize for a predetermined period each time it is started up Pr Will run continually Pr30 Will run for 30 min following start up Pr60 Will run for 60min following start up Pr90 Will run for 90min following start up Status led s Electrolysis production ENTER button Right button Left button START UP 4 INITIAL ADJUSTMENTS 3 Water adjustments 1 Adjust the al...

Page 4: ...OVE INCRUSTATIONS Scratching the edges or surface of the cell will make it vulnerable to chemicals deteriorate the cell and annul the guarantee Titanium cell maintenance During the first 10 15 days your pool system will require more attention and the following care 1 During the Use of the Ionizer it is important not to exceed copper concentrations of more than 0 5 PPM in the water For this reason ...

Page 5: ... increase pH minimum water pH CONTROLS THE base PUMP optional equipment pH PROBE CALIBRATION Insert probe in pH 7 sample wait till reading has stabilized RECOMMENDED LEVEL 6 8 RECOMMENDED LEVEL 7 2 7 5 Clean probe in NEUTRAL Insert probe in pH 10 sample and wait till reading is stable Calibration correct Repeat calibration or change probe Redox SET POINT To modify parameters Redox set point To con...

Page 6: ...ion 3 water preparation Check for incrustations on cell See troubleshooting Hydrolysis does not reach maximum intensity White flakes in pool This happens in excessively hard unbalanced waters Balance the water and check the cell proceeding to clean it if necessary Hydrolysis display shows FL Check flow detector cable Clean incrustations of flow detector at top of cell casing Check system is free o...

Reviews: