background image

STREBEL 

S-AF XL 

 

 

Floor standing high efficiency boiler 

 

                    User Manual

 

 

 

  

 

                      

 

 

 

 

 

 

 

 

 

2015-06-15 v1.0

 

Summary of Contents for S-AF XL

Page 1: ...STREBEL S AF XL Floor standing high efficiency boiler User Manual 2015 06 15 v1 0 ...

Page 2: ...is type of appliance using exclusively original spare parts when necessary This manual is an integral part of the appliance and as such must be conserved with care for future consultation or transfer to another Owner or User Kind regards Company Management The S AF XL appliances comply with the following Gas directive 2009 142 EC Efficiency Directive 92 42 EEC Low voltage directive 2006 95 EC Elec...

Page 3: ...TED ACTIONS 4 DESCRIPTION 5 DEVICES 5 CONTROL PANEL 6 IGNITION AND SHUTDOWN 9 MENU NAVIGATION TREES AND PROCEDURE 10 SCHEDULER SETTINGS 13 TEMPORARY SHUTDOWN OR HOLIDAY SCHEDULE 15 MAINTENANCE 17 ROUTINE CLEANING 17 NOTES 18 3 USE SYSTEM SUPERVISOR ...

Page 4: ...vice the appliance at least once a year SAFETY WARNINGS AND REGULATIONS b IT IS STRICTLY PROHIBITED to allow children or disabled persons to change settings on the appliance without assistance IT IS STRICTLY PROHIBITED to activate electrical devices or equipment such as switches telephones household appliances etc if smells of fuel or uncombusted fuel are detected In this case Open doors and windo...

Page 5: ...ring these periods The design phase adopted specific solutions to obtain a constantly optimal air gas mix minimise dispersions reduce noise levels to a minimum The S AF XL heating units are designed for connection to 0 10 V DC controls and for operation in cascade in sets of up to 6 units and can be equipped with various system accessories such as the mix bottle or water shut off valve and the ISP...

Page 6: ...PPLY TEMPERATURE READING DOMESTIC HOT WATER REQUEST ACTIVE OUTSIDE SENSOR TEMPERATURE READING OPERATING MODE INITIAL SCREEN SET TIME BOILER WATER PRESSURE HEATING REQUEST ACTIVE Sbs Block indicator light due to intervention of safety devices DSP User interface with display Ip Main switch with indicator light Fu Main fuse 10A Vf Flame screen Sbs Fu Ip Vf DSP 6 USE SYSTEM SUPERVISOR ...

Page 7: ...anual Test function active Monday 24 September 2012 OUTSIDE 7o C 69o 0 0 ON OFF 09 37 Monday 24 September 2012 OUTSIDE 7o C 69o 0 0 OFF 09 37 ON Monday 24 September 2012 OUTSIDE 7o C 69o 0 0 ON ON 09 37 date OUTSIDE 7o C 69o 0 0 OFF OFF time J ECO Manual This reduces by the set value the temperature of domestic water supply and heating water energy saving mode Monday 24 September 2012 OUTSIDE 7o C...

Page 8: ...LIDAY 4 MAINTENANCE 5 SETTINGS 6 DIAGNOSTICS to confirm oK User menu 1 HEATING 2 DOMESTIC HOT WATER 3 HOLIDAY 4 MAINTENANCE 5 SETTINGS 6 DIAGNOSTICS to confirm C OK Enables access to the selected line of the menu or sub menu confirmation of a newly modified value DHW settings 1 DHW setpoint 2 ECO setpoint reduction 3 Scheduler set oK to confirm DHW setpoint 60 oK to confirm A RED at top Enables ac...

Page 9: ...d the main appliance switch Ip to ON The display returns to the stand by screen Press H to activate the keypad for the DSP date time date OUTSIDE 7o C 69o 0 0 OFF OFF time Key Description offunction Display A RED at bottom Enables return to the selected line without saving storing the modified data Keep pressed to speed up the action DHW setpoint 50 oK to confirm A A a DHW settings 1 DHW setpoint ...

Page 10: ...OSTICS to confirm User menu 1 HEATING 2 DOMESTIC HOTWATER 3 HOLIDAY 4 MAINTENANCE 5 SETTINGS 6 DIAGNOSTICS to confirm USER TECHNICIAN See NAVIGATION TREE STAND BY screen INITIAL screen See NAVIGATION TREE USER menu navigation tree and procedure The appliance is supplied in the configuration STAND BY To scroll through the screen menus use the keys shown in the diagram below 10 USE SYSTEM SUPERVISOR...

Page 11: ...2 DHW holiday setpoint C 80 C 30 85 C 4 MAINTENANCE C 1 Service information C read only D B D 2 Service due date C read only 5 SETTINGS C 1 Select Language C English Italiano C Italiano English Italiano D B D 2 Select Units C Fahrenheit Celsius C Celsius Fahrenheit Celsius D 3 Set date C day month year D 4 Set time C 24 hour 12 hour C hours minutes D 5 Restore factory settings C OK to reset 6 DIAG...

Page 12: ...me bands set for the various week days 2 3 2 Scheduler set Settings of the DHW production time bands applied for the various week days 3 HOLIDAY 3 1 CH holiday setpoint Entry of the setpoint for supply temperature during the holiday period 3 2 Instant DHW setpoint Entry of the setpoint for DHW during the holiday period 4 MAINTENANCE 4 1 Contact info Display of services contact phone number 4 2 Ser...

Page 13: ...S 6 DIAGNOSTICS to confirm Heating settings 1 CH temperature OTC set 2 ECO setpoint reduction 3 Scheduler set oK to confirm D TWICE C to select 3 Scheduler set to confirm and access the selected line oK Heating settings 1 CH temperature OTC set 2 ECO setpoint reduction 3 Scheduler set to confirm oK Scheduler set 1 Enable disable on board scheduler 2 Scheduler set to confirm B D C to select Enabled...

Page 14: ... 4 5 6 Monday Friday to confirm to select Save Exit a a A oK 1 05 30 08 00 ON 2 3 4 5 6 Monday Friday to confirm to select Save Exit a a A D C to select Save and exit or Copy to the Next Day if the user wishes to copy the current settings to the next day to save the settings made and return to the line of the single day or group of week days selected previously Copy to the Next Day oK 1 05 30 08 0...

Page 15: ...line oK User menu 1 HEATING 2 DOMESTIC HOT WATER 3 HOLIDAY 4 MAINTENANCE 5 SETTINGS 6 DIAGNOSTICS to confirm oK Holiday 1 CH holiday setpoint 2 DHW holiday setpoint to confirm C A OR A C to select 1 CH holiday setpoint to set the required value to confirm the settings and return to line 1 CH holiday setpoint CH holiday setpoint 50 oK to confirm oK Holiday 1 CH holiday setpoint 2 DHW holiday setpoi...

Page 16: ... to set the year to confirm the settings made and enter the Holiday end screen NOTE to make the settings for the day month and year of the holiday end follow the same procedure as described for Holiday start Holiday start 30 10 2012 oK to confirm a a A Holiday start 30 10 2012 oK to confirm a a A Holiday start 30 12 2012 to confirm oK a a A Holiday start 30 12 2012 oK to confirm a a A Holiday star...

Page 17: ...ater and detergent In the case of stubborn stains dampen a cloth with a mix of 50 water and denatured alcohol or with special products After cleaning dry the appliance thoroughly WARNINGS Never use abrasive products benzene or trichloroethane MAINTENANCE Note that it is a COMPULSORY LEGAL REQUIREMENT THAT THE BOILER SUPERVISOR must arrange for PERIODIC MAINTENANCE and COMBUSTION EFFICIENCY MEASURE...

Page 18: ...NOTES 18 USE SYSTEM SUPERVISOR ...

Page 19: ......

Page 20: ...urrey GU16 7PB Tel 01276 685422 Fax 01276 685405 Email info strebel co uk Web www strebel co uk Further information on our complete product range is available from our website CAST IRON CONDENSING STEEL SHELL WATER HEATERS RENEWABLES FLUES ACCESSORIES RADIATORS 008074132 ...

Reviews: