Summary of Contents for SOL 27 BASIC

Page 1: ... CeC eC CZ HC HT V HC C CZ HC e Z HC CZ HC eZH CZ x HC C C C CZ H Z eC Zé H HV T V HVB C éT H HV T eV T e T V HVB C H HV T H H V C B C H T H HV B HH V C B C á ZH ŝŌ Z á ZH ŝŌ Z q ...

Page 2: ...ipment description ____________________________________ 24 8 1 Standard delivery_______________________________________________24 9 Installation__________________________________________________ 24 9 1 Preparations _____________________________________________________24 9 2 Pipework installation __________________________________________24 9 3 Air vent valve _______________________________________...

Page 3: ...t description The flat plate collector converts light into heat The light penetrates the glass cover This is made from pre stres sed highly transparent single pane safety glass The light strikes the absorber and is converted there into heat The highly selective coating of the absorber and the thermal insulation on the back of the absorber reduce heat losses to the ambience to a minimum A circulatin...

Page 4: ... cause Please consult a qualified contractor The pump appears to open late and switch itself off early Please consult a qualified contractor The pump starts and switches itself off again shortly afterwards This repeats a few times until the system runs correctly The same hap pens in the evening There is still too little insolation to heat up the entire pi pework Check for faults again when there i...

Page 5: ... they are installed Damage to the appliance and environment Be careful not to drop the collector Be careful not to drop any objects on the collector Do not step onto the collector Damage to the appliance and environment Do not leave the collector unsecured It the collector falls down the glass may break 8 Equipment description The collector is fitted with a full area aluminium absorber with highly ...

Page 6: ...ofs with more severe inclination For flat roofs and corrugated roofs with lesser pitches routing the pipes through an external wall is recommended Avoid sawing off pipes to prevent swarf entering the system Use a pipe cutter for swarf free cutting 9 2 1 Soldered lines Soldered lines must be brazed Use solder to DIN EN 1044 CP105 and CP203 Use this solder without flux Only solder gunmetal and brass fi...

Page 7: ...ntral heating 1b Manual air vent valve 2 Control unit 2a Outside temperature sensor 2k Temperature sensor in the collector sensor well 2s Solar thermal system cylinder temperature sensor 3f Solar thermal system DHW heating circuit pump 4 Solar module 5 Safety valve 6 Expansion vessel 7 Cylinder 10 Fill drain valve 11 Alternative heat source heat pump for example 16 Set temperature remote controlle...

Page 8: ...b 2m b 2 but 1m D 2m Roof outlets include components that protrude more than 0 35m above the upper edge of the roof material at one or more points and that have a side measurement of at least 0 5m The width of the associated edge area D is 1 2 of the longer component side b but at least 1m The edge area may be limited to 2m in width 10 1 2 Standard snow loads for Germany When installing the solar ...

Page 9: ...llectors The collector connection on the left side has a male thread and the collector connection on the right side has a union nut 26_05_01_0129 10 5 Fitting the collector sensor well The correct connection of the collector sensor is crucial to the correct function of the solar thermal system Assemble the collector sensor well at the collector flow which is the warmest place of the collector array...

Page 10: ...tors thoroughly flush the pipework installed in the building with water so that no foreign matter remains in the system Note Flush the system with fresh water and not with heat transfer medium Damage to the appliance and the environment Avoid frost periods when you flush the system with water Use a powerful pump with an operating pressure of approximately 0 4MPa 4bar for flushing Alternatively you ca...

Page 11: ...f the fill pump to the fill drain valve beneath the pressure gauge f Connect the heat transfer medium container to the inlet side of the pump f On the lower fill drain valve attach a drain hose and route it into the heat transfer medium container f Close the adjusting valve in the solar module by turning the slot on the flow rate adjusting screw above the flow rate dis play to the horizontal position f...

Page 12: ...e collector sensor well and the roof outlet with thermal insulation which must be tightly sealed and must be temperature and UV resistant f If necessary cut into the side of the insulation material and seal the slit with adhesive tape after installation f Where required protect the thermal insulation against bird or rodent attack 11 Commissioning f Retighten all fittings f Check the system s filling...

Page 13: ...ed into the collector sensor well The pump is running but no flow rate is di scernible at the flow meter with balancing valve The flow and return temperatures are identical or the cylinder temperature does not rise or rises only slowly There is air in the pipework the system pressure is too low or the system is contaminated Check the system pressure Check whether the selected expansion vessel is l...

Page 14: ...s after filling There are two possi ble causes if this occurs later The system pressure is too low The pump draws in air via the air vent valve Check whether the selected expansion vessel is large enough Check the pre charge pressure of the expansion vessel In crease the system pressure The pump rate is too high Change to a lower pump rate and check the flow rate at the flow meter with balancing v...

Page 15: ...ŗÔ ZH ŝŌ Z qqqĪZ é VHCĪ HB CZ HC ZT HC CZ HC ZT HC 14 Specification 14 1 Dimensions 14 1 1 SOL 27 basic 80_05_01_0002 14 1 2 SOL 27 basic W 80_05_01_0003 ...

Page 16: ...t medium Water at the factory Water at the factory Heat transfer medium H 30 L LS H 30 L LS Fill level heat transfer medium l 1 3 1 7 Nominal volume flow l h 50 300 50 300 Angle of inclination 20 85 20 85 Total area m 2 53 2 53 Aperture area m 2 39 2 39 Absorber area m 2 38 2 38 Absorber Aluminium highly spec Miro Therm coating copper pipes laser welded Aluminium highly spec Miro Therm coating cop...

Page 17: ... 75 16 5 0 80 1 9 17 86 1 21 7 25 7 75 16 5 0 80 7 5 6 2 7 1 3 1 25 7 25 7 75 16 5 0 80 167 7 7 6 7 9 9 5 7 6 87 2 9 9 6 23 1 1 6 7 121 5 7851 9 9 7 9 7 3803 5283 66 0 16758 7 216 6 7 2 725 7 03 5 785 6 1625 02817 7 7 63 326 7 21 1 75 211 7 3 86 3 86 3 86 3 86 27 5 21752 6 7 75 5 1 1 3 5 250 1 25 1 7 7 7 7521 5 1 5 0 6 7 62 5 21752 6 7 25 1 72 7 167 7 21 1 23 5 7 1 16758 7 216 6 7 7 67 581 2 7 5 8...

Page 18: ... OHQH JO FRO 8SSHU H SORVLRQ OLPLW YRO 3URS OHQH JO FRO JQLWLRQ WHPSHUDWXUH QRW DSSOLFDEOH 1 9DSRXU SUHVVXUH DW DSSUR PEDU HQVLW DW DSSUR J FP 1 6ROXELOLW LQ ZDWHU XQOLPLWHG 6ROXELOLW TXDOLWDWLYH VROYHQWV VROXEOH LQ SRODU VROYHQWV S YDOXH 670 9LVFRVLW NLQHPDWLF DSSUR PP V 1 6XEVWDQFH SUHSDUDWLRQ DQG FRPSDQ QDPH 7UDGH QDPH 7 2 25 UHDG WR XVH YRO IURVW SURWHFWLRQ Ň 8VH HDW 7UDQVIHU OXLG IRU 7KHUPDO ...

Page 19: ...DO FRQVLGHUDWLRQV 7KH SURGXFW PXVW EH GXPSHG RU LQFLQHUDWHG LQ DFFRUGDQFH ZLWK ORFDO UHJXODWLRQV RQWDPLQDWHG 8QFRQWDPLQDWHG SDFNV FDQ EH UH XVHG 3DFNV WKDW FDQQRW SDFNDJLQJ EH FOHDQHG VKRXOG EH GLVSRVHG RI LQ WKH VDPH PDQQHU DV WKH FRQWHQWV 7UDQVSRUW LQIRUPDWLRQ 1RW FODVVLILHG DV KD DUGRXV XQGHU WUDQVSRUW UHJXODWLRQV 5 5 15 0 96HH 2 7 7 2523 6DIHW DWD 6KHHW DWH 5HYLVHG 3ULQWLQJ GDWH 3URGXFW 7 2 25...

Page 20: ... 3 B A9 A 5 B I T 30 2 3A 3 I 7 4 AB7303 3 B A3 316 7 C3 3 D713 3 I 7 4 63 B316 A3 EEE AB7303 3 B A3 3BH70 23 AB 1 I BB3 3 I F 7 4 AB7303 3 B 16 EEE AB7303 3 B 16 A7 B2 0 5 79 C 5 I GCBB6 G 3 I F 7 4 AB7303 3 B A7 1 EEE AB7303 3 B A7 1 1 3AB B 33B I 3AB B473 2 3 I F 7 4 AB7303 3 B CA 1 EEE AB7303 3 B CA 1 0 B7303 B K3 I H 7 23 3 I F 7 4 AB7303 3 B 23 EEE AB7303 3 B 23 3 I F I 7 4 13 B3 AB7303 3 B ...