 IMPORTANT -  CE  &  SAFETY REQUIREMENTS 

Product must be mounted, inside a suitable enclosure providing environmental protection to IP65 or greater.

To maintain CE EMC requirements , input  wires  must be less than 3 metres.

The product contains no serviceable parts , or internal adjustments. no attempt must be made to repair this product. Faulty units must be returned to supplier for repair.

This product must be installed by a qualified person. All electrical wiring must be carried out in accordance with the appropriate regulations for the place of installation.

Before attempting any electrical connection work, please ensure all supplies are switched off.

ABSOLUTE MAXIMUM CONDITIONS ( To exceed may cause damage to the unit) :-

Supply Voltage

± 30 V dc  (Protected for over voltage and reverse connection)

Current with over voltage

± 100 mA

Input Voltage

± 3 V  between any terminals

Ambient

Temperature 

(-40 to 85) °C  Humidity (10 to 95) % RH (Non condensing)

 USER GUIDE

SMART PCB TRANSMITTER INPUT PT100
TWO WIRE (4 to 20) mA  

Every effort has been taken to ensure the accuracy of this document, however we do not accept responsibility for damage, injury, loss or expense resulting from errors and omissions, and we reserve the right of amendment without notice.

Important - Please read this document before any installing.

PRODUCT

 

SPECIFICATION

RECEIVE

 

AND

 

UNPACKING

CONFIGURATION

Please

 

refer

 

to

 

the

 

product

 

data

 

sheet

 

for

 

full

 

specification.

Please

 

inspect

 

the

 

packaging

 

and

 

instrument

 

thoroughly

 

for

 

any

 

signs

 

of

 

transit

 

damage.

 

If

 

the

 

instrument

 

has

 

been

 

damaged,

 

please

 

notify

 

your

 

supplier

 

immediately.

The following parameter can be configured by simply entering as prompted by the software package. 

· Low range 
· High range
· Units      (°C, °F)
· Burnout (direction of output current on sensor burnout)

Factory

 

default:

Low

 

Range

=

 

0

High

 

Range

=

 

100

Units

=

 

°C

 

Burnout

=

 

UPSCALE

 Input PT100

1

2

3

2 Wire (4 to 20) mA 

Output

PT100

+

-

s

Loop
Load

+

-

IMPORTANT

 

Do

 

not

 

attempt

 

to

 

configure

 

the

 

Transmitter

  

when

 

connected

 

to

 

a

 

loop

 

supply.

COMMS

Pt 100

USB SPEEDLINK SOFTWARE

COMPUTER

USB CABLE

 USB CONFIG-UNIT

Red

 

+

Black

 ‐

CONFIGURATOR