Thank  you  for  purchasing  the  WINSTAT  BF-OHP3B  3-Fan  type  Static  Eliminator.  Please  read  this  manual 
before using the product in order to fully understand its functions. Also make sure to store this manual so that it 
can be referred to in the future. 
 

 

Warning 

 

This  Product  is  not  specified  as  an  Explosion-proof  Type.  Do  not  use  this  unit  at  a  location  or  an 
atmosphere, in which combustible gas or solvent is handled, or else ignition or explosion may occur. 

 

 

High Voltage 

  A  high voltage  is  applied to the  discharge needle.  Do  not  allow  any  conductive material,  including  your 

finger, any part of your body, wire or any tool to get close to the needle, or an electrical shock accident or a 
malfunction of the Unit may occur. 

 

1. Safety Precautions 

  Installation   

 

Install the product in a location where the power indicator and output signals can be easily checked. 

 

This product emits ozone into an atmosphere. Do not use this product in an enclosed space. 

 

Do not install the product in any of the following locations, as doing so may cause fire or electrocution. 

Locations subject to high temperature, or high 
or low humidity 

Dusty locations 

Locations where the air inlet of the fan will be 
blocked 

Locations  where  the product may be exposed 
to organic solvents such as thinner 

Locations subject to condensation 

Locations  where  the product may be exposed 
to corrosive gas 

Locations subject to flames or explosions 

Locations subject to frequent vibrations 

Locations  subject  to  sudden  changes  in 

temperature or humidity 

Locations  where  the product may be exposed 
to water or oil 

 

  Power Supply   

 

Make sure to grasp the plug when removing the power cord. Pulling the power cord by the cord may cause it 
to break, or become damaged and have its core be exposed, which may cause a short circuit, or current 
leakage and electrocution. 

 

Make sure to insert the power cord firmly into the power socket. Failure to fully insert the power cord into the 
socket may cause fire or electrocution. 

 

Do not insert or remove the power cord with wet hands. Doing so may cause electrocution. 

 

Do not step on the power cord or place heavy objects on it. Doing so may cause damage to the cord. 

 

Make sure to use the power cord included with the product. (INPUT: 100V to 240V 50/60 Hz) 

 

  Maintenance   

 

Periodically  remove  the power  cord and  wipe  any  dust on  the  power  socket  away  with  a  dry  cloth. If  you 
leave the power cord inserted in the power socket for a long period in a location with high humidity, dust, or 
oil, the dust will absorb the humidity, etc., which may result in a short circuit, and cause a fire. 

 

Make sure to turn the power of the product OFF before removing the power cord for cleaning. 

 

Use water (or a neutral detergent) when cleaning the filter or front louver. Also, add IPA(isopropyl alcohol) to 
the cloth when cleaning the discharge needles. Make sure the IPA has dried before re-inserting the power 
cord. 

 

  Handling   

 

Do not disassemble or modify the product. 

 

The product may affect medical devices such as hearing aids or pacemakers. 

 

Take care when using the product, as its internal parts are subject to high voltage. 

 

Do not insert any foreign objects into the product. Doing so may result in a short circuit or current leakage, 
and cause fire or electrocution. 

 

Make  sure  to  connect  the  earth  wire  to  an  appropriate  place.  Forgetting  to  connect  the  earth  wire,  or 
connecting the earth wire to an inappropriate place may cause electrocution. 

 

For safety purposes, remove the power cable if you plan on not using the product for an extended period of 
time. 

 

If the product emits any abnormal odors or sounds, smoke, or heat, turn OFF the main power immediately, 
remove the power  cord,  and  contact  your  point  of  purchase.  Failure to do so may  result  in fire or  a  short 
circuit. 

 

Do not directly touch the discharge needles with your hands. 

 

Do not remove name plates or labels. 

 

Do not do anything with the product that is not described in this manual. 

 

2. Outline 

 

This product uses a fan to blow air ionized with the corona discharge of an electrode to eliminate the static 
electricity in electrically charged materials that are located at a distance. 

 

This product is an overhead type requires no desk space, and can neutralize electricity over a large area. 

 

HDC-AC corona discharge system enables a balanced amount of positive and negative ions to be released 
for high neutralization performance. The performance of the product also deteriorates little with age, making 
it low maintenance. 

 

The high voltage output of the product are monitored and displayed on a monitor panel. 

 

The front louver can be easily removed/attached for easy electrode maintenance. This product also includes 
a safe circuit design that ensures that the high voltage output and fan stop when the louver is removed. 

 

 

Static Clean International / 781-229-7799p / 781-229-4555f 

                                                         

www.staticclean.com

   

 

3. Specifications 

  List of Specifications   

Model No. 

BF-OHP3B 

Input voltage 

100 V to 240V AC, 50/60Hz 

Power consumption 

42VA max 

Fuse 

1 A 

High voltage output 

±

  7,500 V o-p approx. 

Ion balance (NOTE1) 

±

10 V or less 

Static charge removal time (NOTE1) 

2.5 sec. approx. 

Display LED 

Power: Green / High voltage alarm: Red 

Airflow 

                        Low speed: 93cfm x 3fan    High speed: 142cfm x 3fan 

Quantity of produced ozone 

0.005 ppm or less(at the center of the fan outlet [150 mm]) 

Ambient temperature 

0 to 40°C (32-104°F) 

Ambient humidity 

15 to 85% ( No condensation allowed ) 

Dimensions: (mm) 

40”W×2.4”H×6”D (Main unit only) 

Weight 

11 lbs approx. (including stand) 

Filter 

Prefilter class 

Accessories 

Instruction manual (this document), Power cord, Cleaning brush 

 

Note1: Typical value at a distance of 450 mm from the center of the each fan outlet, at maximum flow rate. (before shipment) 

 

  Appearance   

POWER

H.V ALARM

AIR   IONIZER

WINSTAT

 -OHP3B

 BF-

HIGH

LOW

FLOW

FUSE 1A

POWER

OFF

ON

 

100-240V ` 50/60Hz

INPUT

1020

110

400

400

110

1

5

0

6

0

.5

60

94

128

1

0

POWER (Green)

H.V ALARM (Red)

FLOW (Air flow adjustment knob)

Power switch

AC inlet

Fuse holder

Filter cover

Filter

Louver

4-

φ

5.5 Fixing holes

4-

φ

12 Fixing holes

 

 

4. Installation 

 

Make sure to turn the power of the product OFF before removing the power cord for installing the product. 

 

 

Using the fixing  holes  on  both sides  of  the main  unit, suspend  it from the 
ceiling with a chain. Alternatively, using brackets, it is possible to install this 
product in a variety of ways, such as on a shelf, vertically, or as a standing 
type. 

 

Note1: Install this device such that air flow is not obstructed. 

 

5. Wiring 

 

Connect the power cord to main unit and insert the plug into an alternating 
current (AC 100 to 240V) power outlet.   

*This  product  is  available  with  input  voltage  of  AC100V  -  240V.  However,  an 

attached power cord is available with input voltage of AC100V only (less than 
AC125V). If you use this product with input voltage of AC125V higher, prepare 
another power cord which suited to input voltage. 

 

When  connecting  to  a  grounded  power  outlet,  use  the  3-pin  plug.  When 
connecting  to  an  ungrounded  (2-pin)  power  outlet  using  the  adapter 
included with the product, be sure to ground the earth terminal. If it is not securely grounded, the product 
may not be able to work up to the fullest performance. 

 

6. Operation 

(1)  Turn  the  power  switch  of  the  product  ON,  and  green  POWER  LED  becomes  light  up.  The  electrode 

becomes  charged  with  high  voltage,  releases  corona  discharge,  and  generates  neutralizing  ions.  At  the 
same time, the fans spin, and blow neutralizing air from the front of the main unit. Charged materials placed 
in the neutralizing air will be immediately neutralized. 

(2)  The flow of the neutralizing air can be adjusted using the air flow adjustment knob. 
(3)  The operating status is displayed on the front monitor panel. If there is a high voltage output irregularity, the 

red H.V ALARM LED lights up. 

(4)  Turn the power switch OFF to stop the products. 
 

7. Maintenance 

 

Before  care  and  maintenance  of  the  product,  make  sure  to  turn  the  power  of  the  product  OFF  before 
removing the power cord. Otherwise accidents or operating problems may occur. 

 

The tip of the discharge needle is sharp, be careful not to touch the discharge needle. 

 

When the product is used for long periods of time, the discharge needle and the air inlet/ outlet section will 
get dirty. Clean the discharge needle and the air inlet/ outlet section regularly, otherwise you could not get 
the desired effect, and accidents and operating problems may occur.   

 

The maintenance required depends on the environment of use. As a reference, cleaning both the discharge 
needle unit and fan filter should be done once 3,000 hours. 

 

The discharge needle is a part having a product life time. If the charge removal performance is not restored 
after cleaning the  discharge  needle,  it  is  recommended to  replace  the  entire discharge needle  unit  with  a 
new one. The expected life span is seemed to be 20,000 hours In case of natural wear and use. 

 

If you use the discharge needle unit or fan filter for replacement mentioned, please purchase below.   

・・

DNU-W85

 : Discharge needle unit             

・・

OBF-F2ZA-1-10

 : Fan filter (10 pcs.) 

 

  Cleaning the Front Louver   

(1)  Push  in  the tabs  on both sides of the front  louver, and  pull  it towards 

yourself  to  remove  it  from  the  main  unit.  Clean  the  louver  using  the 
included  cleaning  brush.  If  the  louver  is  extremely  dirty,  wash  it  with 
water (or a neutral detergent).   

(2)  Re-attach the front louver to the main unit after drying it thoroughly. 
 

  Cleaning the Discharge needles   

(1)  Remove the front louver. 
(2)  Clean  the  discharge  needles  using  the  included  cleaning  brush.  If  the 

discharge  needles  are  extremely  dirty,  it  is  recommended  you  add  IPA 
(isopropyl alcohol) to the cleaning brush. 

 

  Replacing the Discharge needle unit   

(1)  Remove the power cord and move the main unit to the horizontal place. 
(2)  Remove the front louver. 
(3)  While  securely  holding  down  the  Main  Unit  in  place,  remove  the  Discharge  Needle  Unit  by  gripping  the 

Finger Grip at the center of the Discharge Needle Unit and turning it in the direction of FREE (clockwise), 
and releasing the Unit. 

                                           

Discharge 
Needle unit

 

(4)  Prepare a new set of discharge needle unit. 
(5)  Align the protrusion on the Main Unit in the section to be engaged with the discharge needle unit with the 

engaging section on the discharge needle unit. Press the discharge needle unit into the Main Unit, so that 
both  units  will  be  engaged  with  each  other.  Turn  the  discharge  needle  unit  in  the  LOCK  direction 
(counterclockwise) until the discharge needle unit is securely locked with the Main Unit. 

                                           

Protrusion in the 
engagement section

 

 

Note1:  Turn  the  discharge  needle  unit  until  securely  locked.  The  correct  installation  of  the  discharge  needle  unit  on  the  Main  Unit  is 

essential for the optimum operation of the Product. 

 

  Cleaning the Filter   

(1)  Check that the power is turned OFF. 
(2)  While  securely  holding  down  the  main  unit  in  position,  remove  the  filter 

cover.  The  filter  cover  may  be  easily  removed  by  gripping  the  side  of  the 
filter cover and pulling it. 

(3)  Clean the soiled or clogged the filter. If the filter is extremely dirty, wash it 

with water (or a neutral detergent), and drying it thoroughly. 

(4)  Re-attach the filter to the main unit. 
 

8. Troubleshooting 

Problem 

Main case 

Remedy 

The power cannot 
be supplied to the 
product. 

Power cord not connected 

Check to see if the AC plug is securely inserted into the product and 
the wall outlet. 

Louver not installed 

Check the Louver to confirm that it is correctly installed. 

H.V. ALARM LED 
(red LED)   
lights up. 

Abnormal discharge 

Check that the discharge needle is free from conductive materials. 
Clean  the  discharge  needle.  But  H.V.  ALARM  LED  remains  light 
even  after the discharge  needle  has been cleaned, clean the area 
around the needle is dirty. 
Check  that  the  discharge  needle  unit  to  confirm  that  it  is  correctly 
installed. 

Internal circuit is broken 

Turn off the power, and then turn the power back on. 

 
 

 

  Letter of Guarantee   

 

1. This product has passed the inspection carried out by our company. This product will be subject to repair or replacement, free of 

charge, of  any failed  or  broken  part, if  a  failure  or a  breakage  should  occur  during  the  guarantee  period  under  the  condition  of 
normal use, caused by a defect in the design or manufacture by our company. 

2. The Period of Guarantee: One (1) year starting from the date of delivery. 
3. Any repair work or replacement for any failure or breakage caused by any of the following reasons will be carried out by the user 

bearing the cost: 

(1)Any failure or breakage caused by usage or storage not under the normal condition. 
(2)Any failure or breakage caused by an unauthorized repair or a modification carried out by other person than our company, or 

not in accordance with the specifications provided by our company. 

(3)Any failure or breakage caused by a disaster or force majeure such as fire, natural calamity, or an act of God. 
(4)Any failure or breakage caused by any other reason that cannot be attributable to our company. 

 

Product Name 

Air Ionizer 

(Fan type Ionizer) 

Model Name 

  WINSTAT model BF-OHP3B 

Serial Number 

 

Date of 

Delivery 

 

Inspection 

Seal 

 

 
 

 

 

 

Ver.1.10      2013.10.31

 

Reviews: