Ultra flat Pool & Spa LED light

OWNER’S MANUAL

Ultra flat shape

2 wire 12VAC

ON/OFF control

NoAir™

PAR56 Retrofit

Содержание Moonlight PLS300B

Страница 1: ...Ultra flat Pool Spa LED light OWNER S MANUAL Ultra flat shape 2 wire 12VAC ON OFF control NoAir PAR56 Retrofit ...

Страница 2: ...contents Installation instructions Retrofit with PAR56 niche 16 color programs only for RGB lamps Operation Wiring instructions Setup 1 Wiring instructions Setup 2 Troubleshooting Page 3 Page 4 Page 5 Page 6 Page 7 Page 7 Page 8 Page 9 Page 10 page 2 of 12 ...

Страница 3: ...5 lm 575 lm 1250 lm 1250 lm 1450 lm 1450 lm 2100 lm 2100 lm 925 lm 1850 lm Power 15W 15W 16 W 16 W 25W 25W 28W 28W 21W 19W Nominal CCT n a n a 9000K 9000K n a n a 9000K 9000K n a 9000K Color RGB RGB White White RGB RGB White White RGB White Beam Angle Diameter Optic Nominal input Voltage Life time hrs Power factor 120 170 mm 12 VAC 25 000 h 0 73 Moonlight Pool lamps must be completely submerged in...

Страница 4: ...page 4 of 12 Box contents PLS300B PLW300B PLS700B PLW700B PLS400B PLW400B PLS300 PLW300 PLS700 PLW700 Moonlight complete types Moonlight Bulb only types ...

Страница 5: ...Installation instructions page 5 of 12 No liner Use 1 gasket With liner Use 2 gaskets OR 1 2 3 ...

Страница 6: ...page 6 of 12 Retrofit with PAR56 niche 1 2 4 3 ...

Страница 7: ...Select the desired color 2 Turn the lamps OFF for MINIMUM 12 seconds 3 The chosen color has now been memorized 5 6 7 8 9 10 11 12 13 14 SUN WHITE RED GREEN BLUE GREEN BLUE RED GREEN BLUE RED EVENING SEA EVENING RIVER RIVIERA NEUTRAL WHITE RAINBOW RIVER OF COLORS DISCO FOUR SEASONS PARTY warm white fixed color red fixed color green fixed color blue fixed color green blue fixed color red green fixed...

Страница 8: ...ations LAMP TYPE 1 5 mm2 2 5 mm2 4 0 mm2 6 0 mm2 VA TRANSFORMER 12VAC MAX CABLE LENGTH BY CABLE SECTION The transformer VA rating must be greater or equal to the sum of VA ratings of all connected lamps These cable lenghts are calculated with worst case voltage drops in the electrical wiring PLS300 B PLS400 B PLS700 B PLW300 B PLW400 B PLW700 B 70m 70m 60m 90m 60m 50m 120m 120m 100m 150m 100m 85m ...

Страница 9: ...A rating must be greater or equal to the sum of VA ratings of all connected lamps These cable lenghts are calculated with worst case voltage drops in the electrical wiring PLS300 B PLS400 B PLS700 B PLW400 B PLW300 B PLW700 B 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 120m 60m 35m 25m 100m 50m 30m 25m 150m 75m 50m 35m 85m 40m 25m 20m 180m 90m 60m 40m 160m 80m 50m 40m 200m 120m 80m 60m 140m 70m 45m 35m 200m 2...

Страница 10: ...te the synchronization procedure as ex plained on page 7 Check the output voltage at the transformer terminals This volt age should be between 12VAC and 13VAC Verify that the used trans former VA rating is sufficient for powering all connected lamps Verify if the cables that are used to connect the lamps to the trans former are correctly dimensioned see tables p 8 9 Check if there are no bad conta...

Страница 11: ...ame Marc Lamberts Position GM Place Brussegem Belgium Date 11 10 2013 EU 1194 2012 EC 1907 2006 2011 65 EU 2004 108 EC 2012 19 EU I hereby declare that the equipment above named has been designed to comply with the relevant sections of above referenced specifications The unit complies with all applicable Essential Requirements of the Directives General requirements and tests Luminaire Part 2 Lumin...

Страница 12: ...vba Dooren 72 1785 Merchtem Belgium Tel 32 2 461 02 53 Fax 32 2 706 59 60 www propulsionsystems be info propulsionsystems be We reserve the rights to change all or part of the contents of this document without prior notice 402 0023 141203 ...