manualshive.com logo in svg
background image

 

  

July 2008 Edition 

 1725-36124-001 
 Version 

SpectraLink 6300 MCU 

Open Applications Interface (OAI) 

Installation and Configuration 

SpectraLink 6000 System 

Содержание SpectraLink 6300 MCU

Страница 1: ...July 2008 Edition 1725 36124 001 Version E SpectraLink 6300 MCU Open Applications Interface OAI Installation and Configuration SpectraLink 6000 System ...

Страница 2: ...ccurate Polycom Inc is not responsible for printing or clerical errors Information in this document is subject to change without notice and does not represent a commitment on the part of Polycom Inc Notice Polycom Inc has prepared this document for use by Polycom personnel and customers The drawings and specifications contained herein are the property of Polycom and shall be neither reproduced in ...

Страница 3: ...pectraLink 6300 MCU Facility Preparation 1725 36121 001 SpectraLink 6300 MCU Installation 1725 36122 001 SpectraLink 6300 MCU Maintenance and Diagnostics 1725 36123 001 SpectraLink 6300 MCU Operator s Console 1725 36125 001 SpectraLink 6300 MCU T1 Remote Module Installation 1725 36126 001 Installing the Outdoor Base Station 1725 36127 001 Available at http www polycom com usa en support voice prop...

Страница 4: ...n Monday through Friday 6 a m to 6 p m Mountain time For Technical Support technicalsupport polycom com For Knowledge Base http www polycom com usa en support voice voice html For Return Material Authorization rmacoordinator polycom com Icons and Conventions This manual uses the following icons and conventions Caution Follow these instructions carefully to avoid danger Note these instructions care...

Страница 5: ...tions 4 1 Installation Overview 7 2 OAI Overview 9 System Diagram 10 3 Install and Configure OAI Card s 11 Upgrade System to Support OAI 11 Verify System and Cabinet Controllers Support OAI 12 Configure COM Port for OAI 13 Connect the Application Server to the MCU 13 Assign Function Key to OAI 14 Test Application 15 4 Safety Notices 17 ...

Страница 6: ......

Страница 7: ...vities among the persons involved 1 Site Preparation Done by the customer or a wire technician contractor 2 OAI Setup Done by the customer or Polycom 3 System Certification Done after installation to confirm the system is working properly For more information about SpectraLink 6000 System architecture and components please see the appropriate SpectraLink 6000 System document 1 ...

Страница 8: ......

Страница 9: ...n server as shown in the diagram below This enables third party applications to communicate directly with the SpectraLink 6300 MCU allowing users to retrieve and respond to information using Wireless Telephones The client system may include a LAN and its server with a TAP line to a communications device such as a paging controller 2 ...

Страница 10: ... Diagram To optional client system Device supplied by SpectraLink Phone cabling RS 232 cable PBX or Key System SpectraLink 6300 MCU Base Station SpectraLink Wireless Telephones Base Station OAI Interface server Administrative computer Wired Telephones to OAI port to Administrative port OAI enabled Controller Card ...

Страница 11: ...xisting system to support OAI perform Upgrade System to Support OAI first then proceed with the installation steps Verify System and Cabinet Controllers Support OAI Configure COM Port for OAI Connect the Application Server to the MCU Assign Function Key to OAI If you have a new system with an OAI card CSO3xx set up the system and then proceed with setting up OAI as outlined above Upgrade System to...

Страница 12: ...l and connect the CSO cabinet controller cards 5 Power up the system Restore system configuration 1 On the Operator s Console go to the directory where the PCS CFG file was dumped your working directory 2 From the Supervisor State Display screen F1 press Enter to display the menu 3 Scroll down to Restore Config from PCS CFG and press Enter The system will copy the configuration from PCS CFG in you...

Страница 13: ...OAI one of the COM RS 232 ports on the MCU must be configured as the OAI port via the following procedure 1 On the Operator s Console select COM Port Administration F10 2 Select the COM port to be assigned to OAI and press Enter 3 In the sub menu select OAI and press Enter The selected port is now configured as the OAI port Connect the Application Server to the MCU Using a standard RS 232 cable co...

Страница 14: ...ng screen displays The screen allows you to define macros for the digits 1 through 9 0 and 2 Use the arrow keys or mouse to move to the desired entry and press Enter 3 To assign a function key to initiate the OAI application enter 555 as the macro key sequence When the related function key is pressed the OAI application will recognize the key sequence and initiate the appropriate OAI application F...

Страница 15: ...e OAI application test the functionality of the handsets and the functionality of the OAI application 1 Place a call and test the features on each handset to be sure the system is working properly 2 Test the application on each handset Consult your application provider for specific test procedures ...

Страница 16: ......

Страница 17: ...ss the jack is specifically designed for wet locations Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface Use caution when installing or modifying telephone lines When installing Base Stations outside or in buildings other than the one containing the System Controller take the following precaution If wiring for a Base Stati...

Отзывы: