background image

last updated: 2018-09-11

OPERATING MANUAL

DMX Relay 3212R-H

Version Mk1

(C) SOUNDLIGHT 1996-2018  *  ALL RIGHTS RESERVED  *  NO PART OF THIS MANUAL MAY BE RE-
PRODUCED, DUPLICATED OR USED COMMERCIALLY WITHOUT THE PRIOR WRITTEN CONSENT OF
THE OWNER  *   ALL STATEMENTS WITHIN THIS MANUAL HAVE BEEN CHECKED CAREFULLY AND
ARE BELIEVED TO BE ACCURATE, HOWEVER SOUNDLIGHT DOES NOT ASSUME ANY RESPONSIBI-
LITY FOR ERRORS OR OMISSIONS.  *   THE USER HAS TO CHECK THE SUITABILITY OF THE EQUIP-
MENT FOR THE INTENDED USE. SOUNDLIGHT EXPRESSLY EXCLUDES ANY RESPONSIBILITY FOR
DAMAGES  -  DIRECT  OR  INDIRECT  -  WHICH  MAY  OCCUR  DUE  TO  MISUSE,  UNPROPER  INSTALLA-
TION, WRONG OPERATING CONDITIONS AND NON-COMPLIANCE TO THE INSTRUMENT'S INSTRU-
CTIONS, AS WELL AS DISREGARD OF EXISTING SAFETY STANDARDS AND REGULATIONS.

SOUNDLIGHT 

The DMX Company 

  Bennigser Str.1  D-30974 Wennigsen  Tel. 05045-91293-11

Summary of Contents for 3212R-H

Page 1: ...CURATE HOWEVER SOUNDLIGHT DOES NOT ASSUME ANY RESPONSIBI LITY FOR ERRORS OR OMISSIONS THE USER HAS TO CHECK THE SUITABILITY OF THE EQUIP MENT FOR THE INTENDED USE SOUNDLIGHT EXPRESSLY EXCLUDES ANY RES...

Page 2: ...loss of the drive signal a pre definable action will be taken cost effective The SOUNDLIGHT 3212R H is a cost effective solution for many purposes Features The DMX Relay 3212R H is a relay module to...

Page 3: ...ght forwarder Make sure you receive such a document and send to us a s a p When unpacking you should identify these items the interface 3207R H RDM this manual Please note that a start adderess board...

Page 4: ...off blinking no valid DMX signal present Yellow RDM Activated when a RDM programming has taken place Optionally connected mechanical address switches start address board are deactivated then Start Ad...

Page 5: ...and wait for a programming cycle to complete A programming cycle is indicated by the red and the green LED blinking four times alternatively DIP Switch Settings The address board DIP Switches c an be...

Page 6: ...nd not to exceed 50 of the resistive load data Besides con tacts may burn due to inductive spikes and sparks Make sure to add protective circuitry RC com binations VDR resistors if switching inductive...

Page 7: ...3212R H is fully compliant to DMX RDM standard 1 0 The devive will be recognized as DMX Relay withing category RELAY_MECHANICAL and can be configured to multiple per sonalities modes of operation Tab...

Page 8: ...DMX start address DMX personality or HOLD mode is done via RDM To re engage the switches set the hundreds position to 9 temporarily any address from 900 to 999 will do and wait for a programming cycl...

Page 9: ...ordance with the manual connection to wrong voltage or current misuse CE Conformity This DMX relay is microprocessor controlled and uses high frequency The inter face has been tested in our EMC lab to...

Page 10: ...s card 3212R H which require the user s attention Should your unit require servicing please send it to the factory freight paid Accessories Setting the DMX start address the DMX personality or the DMX...

Reviews: