background image

DATA PROJECTOR

VPL-ES3

VPL-EX3

VPL-ES4

VPL-EX4

VPL-EX5

VPL-EX50

VPL-EX5U

VPL-EW5

PROTOCOL MANUAL
1st Edition (Revised 3)

Summary of Contents for PL-ES3

Page 1: ...DATA PROJECTOR VPL ES3 VPL EX3 VPL ES4 VPL EX4 VPL EX5 VPL EX50 VPL EX5U VPL EW5 PROTOCOL MANUAL 1st Edition Revised 3 ...

Page 2: ... ausgeführt werden Um die Gefahr eines elektrischen Schlages Feuergefahr und Verletzungen zu vermeiden sind bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden die eine spezielle Befähigung dazu besitzen AVERTISSEMENT Ce manual est destiné uniquement aux personnes compétentes en charge de l entreti...

Page 3: ...1 Introduction 2 RS 232C 2 1 Communication Specifications 1 2 2 Command Block Format 2 2 3 Block Format 3 2 4 Connection 4 2 5 Communication Procedure 4 2 5 1 Outline of Communication 4 2 6 Communication Rules 5 2 7 Approximate Return Waiting Times 5 Appendix ...

Page 4: ......

Page 5: ... device such as a PC which controls projector using these commands 2 RS 232C 2 1 Communication Specifications RS 232C Communication Signal Full duplex communication channels Flow control not performed Start stop synchronism system Baud rate 38 4 kbps bits per second The bit configuration is defined as follows VPL ES3 EX3 1 START Bit 8 DATA Bits 1 STOP Bit Other than above 1 START Bit 8 DATA Bits 1...

Page 6: ... DATA CHECK SUM END CODE 0 x 9A DATA REPLY B5 B6 B7 Transmission from the Master side Reception in the Master side Reception in the Master side With Data B0 START CORD Common in the all FORMAT B6 CHECK SUM B1 to B5 are calculated by OR Example of Calculation 0 x A9 1010 1001 0 x A9 1010 1001 0 x A9 1010 1001 0 x 9A 1001 1010 Answer 1010 1001 Answer 1011 1011 0 x A9 0 x BB B7 END CODE Common in the...

Page 7: ...e 1 for details SET 0 x 00 Set data GET 0 x 01 Get data SET Data to be set Refer to the Appendix Table 2 GET Unused Set Dummy data 0 x 00 0 x 00 Check Sum End of Command Receive results of the data transmission from the Projector Start of Command Results correspond with the data transmission Refer to the Appendix Table 3 for the data in detail 0 x 03 Express Reply data either of ACK or NAK This da...

Page 8: ...irect Command is sent return Data may not be returned in some cases 2 4 Connection RS 232C Connection Communication is enabled by the use of a D Sub 9 Pin cross reverse cable The pin assignment of D Sub 9 Pin and D Sub 25 Pin is as follows Pins indicated as D Sub 25 Pin are not used Assured cable length 15 m However assurance may not be applicable for some cables The software for controlling the p...

Page 9: ... command When a communication error occurs PROJECTOR ignores the Data received until now and set into the reception standby state For undefined commands or commends determined as invalid by PROJECTOR PROJECTOR will send the NAK return Data to CONTROLLER Take note that when Data is written when the input signal of PROJECTOR is unstable that Data value will not be incorporated When INDEX specified S...

Page 10: ...e 0 100 00h 00h 64h Brightness 00h 11h Setting value 0 100 00h 00h 64h Color 00h 12h Setting value 0 100 00h 00h 64h Hue 00h 13h Setting value 0 100 00h 00h 64h Sharpness 00h 14h Setting value 0 100 00h 00h 64h Volume 00h 16h Setting value 0 100 00h 00h 64h Color Temp 00h 17h High 00h 00h Low 00h 01h Wide Mode 00h 20h Off 00h 00h On 00h 01h Scan Converter 00h 21h Off 00h 00h On 00h 01h Picture Mut...

Page 11: ...to table 4 _ 00h 00h Set only 4 Sircs 20 Bit Category 19h Refer to table 5 _ 00h 00h Table 3 Item Number Data IItem Data Upper byte Lower byt ACK _ 00h 00h NAK Select Error 01h 05h Approximate Return Waiting Times The await return time is approx 50 msec n This is the case unless the communications are nterfered anyway 1 Example In case the lamp timer indicates 1000H return values are 03h upper byt...

Page 12: ...ss 00h 11h Set Value 00h 00h 64h 0 100 Color 00h 12h Set Value 00h 00h 64h 0 100 Hue 00h 13h Set Value 00h 00h 64h 0 100 Sharpness 00h 14h Set Value 00h 00h 64h 0 100 Volume 00h 16h Set Value 00h 00h 64h 0 100 Color Temp 00h 17h High 00h 00h Middle 00h 01h Low 00h 02h DDE 00h 18h Off 00h 00h Progressive 00h 01h Film 00h 02h Wide Mode 00h 20h Off 00h 00h On 00h 01h Scan Conv 00h 21h Off 00h 00h On ...

Page 13: ...Sircs 20 Bit Category 19h Refer to table 4 Refer to table 5 _ 00h 00h 00h Set only 4 1 2 3 Table 3 Item Number Data IItem Data Upper byte Lower byt ACK _ 00h 00h NAK Select Error 01h 05h When sending a command wait for at least 50 ms after the reception of response No response may be returned when turning on the power 1 Example In case the lamp timer indicates 1000H return values are 03h upper byt...

Page 14: ...h Set Value 00h 00h 64h 0 100 Sharpness 00h 14h Set Value 00h 00h 64h 0 100 Volume 00h 16h Set Value 00h 00h 64h 0 100 Color Temp 00h 17h High 00h 00h Middle 00h 01h Low 00h 02h DDE Aspect 00h 18h Off 00h 00h Progressive 00h 01h Film 00h 02h 00h 20h PictureMuting 00h 30h Off 00h 00h On 00h 01h AudioMuting 00h 31h Off 00h 00h Normal 00h 01h Zoom 00h 03h Full1 00h 07h Full2 00h 08h Wide zoom 00h 02h...

Page 15: ...rcs 20 Bit Category 19h Refer to table 4 Refer to table 5 _ 00h 00h 00h Set only 4 1 2 3 Table 3 Item Number Data IItem Data Upper byte Lower byt ACK _ 00h 00h NAK Select Error 01h 05h When sending a command wait for at least 50 ms after the reception of response No response may be returned when turning on the power 1 Example In case the lamp timer indicates 1000H return values are 03h upper byte ...

Page 16: ...ommands can also be accepted Only for Ver 1 05 or previous versions of EX4 and ES4 This limitation does not apply to Ver 1 06 or later versions POWER 2 ON OFF HUE PURPLISH HUE _ GREENISH VOLUME UP VOLUME _ DOWN SHARPNESS SHARP SHARPNESS _ SOFT AUDIO MUTING PICTURE MUTING STATUS ON STATUS OFF CURSOR CURSOR CURSOR CURSOR CONTRAST HIGH CONTRAST _ LOW COLOR HIGH COLOR _ LOW BRITNESS BRIGHT BRITNESS _ ...

Page 17: ...13 VPL ES3 EX3 ES4 EX4 EX5 EX50 EX5U EW5 2 20BIT Category Table 5 x0 0x 1x 2x 3x 4x 5x 6x 7x x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB xC xD xE xF APA DOT PHASE FREEZE DIGITAL ZOOM V KEYSTONE DIGITAL ZOOM ...

Page 18: ......

Page 19: ...t la propriété de Sony Corporation Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des opérations ou entretiens de l équipement à moins d une permission écrite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind Die Sony Corporation untersagt...

Page 20: ...English Sony EMCS Corporation 2008DR16 1 Ichinomiya Tec 2006 VPL ES3 SY VPL EX3 SY VPL ES4 SY VPL EX4 SY VPL EX5 SY VPL EX5 CH VPL EX50 SY VPL EX50 CH VPL EX5U SYY VPL EW5 SY VPL EW5 CH E 9 872 786 04 ...