background image

www.sonici.com

Sonic Charger Plus MNR T R

Instructions for Use

Compatible with Sonic Radiant miniRITE T R and 
Sonic CROS MNR T R 

Summary of Contents for Plus MNR T R

Page 1: ...www sonici com Sonic Charger Plus MNR T R Instructions for Use Compatible with Sonic Radiant miniRITE T R and Sonic CROS MNR T R ...

Page 2: ...arger Plus MNR T R Ensure you read this booklet carefully including the Warnings section This will help you get the most benefit from your charger If you have additional questions about the use of your charger contact your hearing care professional About Getting started Daily use Warnings More info ...

Page 3: ...rger itself Intended user Person with hearing loss using a hearing aid and their caregivers Hearing care professional responsible for adjusting the accessory Intended user group Adults and children older than 36 months Use environment Indoor and outdoor Contraindications No contraindications Clinical benefits See clinical benefits of the hearing aid IMPORTANT NOTICE For details on the functionalit...

Page 4: ...harger 8 Temperature conditions 9 Prepare charger 10 Charge the hearing aids 12 Daily use Charging your hearing aids 14 Charging the charger 16 Power bank function 18 Power and charge using other sources 19 Drying your hearing aids 20 Caring for your charger 21 ...

Page 5: ...Warnings General warnings 22 More info Troubleshooting 26 Conditions of use 30 Warranty 32 Compliance statements 36 ...

Page 6: ...ge contents The packaging box contains the following elements This booklet Power plug varies from country to country Charger Cable www sonici com Sonic Charger Plus MNR T R Instructions for Use Compatible with Sonic Radiant miniRITE T R and Sonic CROS MNR T R ...

Page 7: ......

Page 8: ...arnings More info Charger What it is and does Charging ports For hearing aids when charging Battery indicator Displays charging status of the power bank power bank battery levels Power plug For power socket USB cable Insert in power plug ...

Page 9: ...ondition Below 5 C 41 F No charging due to low temperature 10 C to 35 C 50 F to 95 F Best charging condition The charging of hearing aids can take up to 3 hours 5 C to 10 C and 35 C to 38 C 41 F to 50 F and 95 F to 100 F Extended charging The charging of hearing aids can take up to 4 hours Above 38 C 100 F No charging due to high temperature ...

Page 10: ... Prepare charger Insert the USB plug into the power plug Insert the other end of the USB cable into the back of the charger Insert the power plug into a power socket The charger turns ON automatically and begins charging the built in power bank battery Connect to power source ...

Page 11: ...to power the charger s power bank charging status is shown First use Charge the power bank s battery When you use your charger for the first time it is important that you fully charge the charger s built in battery Charger is turned ON ...

Page 12: ... and left colour indicators on the charger s charging ports The RED colour indicator is for the hearing aid on the right hand side The BLUE colour indicator is for the hearing aid on the left hand side The hearing aid LED lights turn ON when the hearing aids are correctly placed in the charger Hearing aid LED light charging status ORANGE Charging GREEN Fully charged Place hearing aids in charger C...

Page 13: ......

Page 14: ...the normal charging time is 3 hours 1 hour 0 5 hour Fully charged 50 charged 25 charged When the battery in your hearing aids is fully charged the charging process stops automatically Charging time may vary depending on the remaining capacity of the battery and between the left right hand side hearing aid The charger s lid serves as protection and storage for your hearing aids During charging when...

Page 15: ...egins charging For more information see your hearing aid s instructions for use IMPORTANT NOTICE Ensure that your charger is powered or that the charger s built in battery is charged when the hearing aid or transmitter is seated in the charging port Otherwise your hearing aids or transmitter will remain turned ON and continue using battery power ...

Page 16: ...charger is plugged into a power source Your hearing aids and the charger s built in battery are being charged When the charger is unplugged from a power source The charger enters Power bank mode letting you charge your hearing aids when you do not have access to a power socket Charging times Power bank battery Power bank hearing aids Up to 4 hours depending on charge level Up to 8 hours depending ...

Page 17: ...d disconnect the charger and consult your hearing care professional When the charger is connected to a power source the LEDs on your charger indicate the charging status of the power bank The LEDs turn OFF shortly after the power bank battery is fully charged Charging Battery too low to recharge the hearing aids Charging Fully charged ORANGE blink ORANGE GREEN ...

Page 18: ...ycles of two hearing aids One full charging cycle of two hearing aids Battery too low for a full charging cycle ORANGE blink GREEN Long term storage Before you put away or store the charger for a prolonged period of time more than 14 days ensure you first fully charge the charger s power bank battery This way the battery can be charged again Note To protect the rechargeable battery it is necessary...

Page 19: ...urces than a power socket This can be done by using the charger s USB cable Ensure that the power source is USB 2 0 compliant with a minimum of 500mA output Examples of power sources Computer Car IMPORTANT NOTICE When using a power socket use the supplied original power supply 5 0V 1A for the charger ...

Page 20: ...uses heat from inductive charging to dry your hearing aids when you place them in the charger ports The drying of your hearing aids is activated when you place the hearing aids in the charger ports and charging begins IMPORTANT NOTICE Ensure you remove the USB cable when you transport the charger ...

Page 21: ...o not use water or cleaning fluids to clean the charging ports Store your charger in a dry location e g in the bedroom Ensure you keep the charger in an environment with a temperature between 5 C and 38 C 41 F and 100 F IMPORTANT NOTICE To clean the charger use a soft dry cloth The charger must never be washed or immersed in water or other liquids ...

Page 22: ...e manufacturer and or the national authorities Usage of charger The charger should be used only as directed and adjusted by your hearing care professional Risk of burns Do not place anything but the hearing aids in the charger ports Choking hazards Charger hearing aids and their parts should be kept out of reach of children and anyone who might swallow these items or otherwise cause injury to them...

Page 23: ...tation due to acids leaking from the battery If your skin has been in contact with the leaked battery acids use a wet cloth to wipe it off and ensure no acid is left on your skin If you experience skin irritation consult your doctor For further handling instructions of your charger consult your hearing care professional The safety of recharging batteries using a USB connector is determined by the ...

Page 24: ...n rare cases cause a skin irritation or other side effects If these conditions occur seek consultation with a physician Transport on aircraft Consult the airline for details regarding transportation of your hearing aid charger on aircraft Caution must be taken with active implants It is recommended to keep the charger at least 15 centimetres away from the implant e g do not carry it in a breast po...

Page 25: ...s are well below international accepted safety limits for SAR induced electromagnetic power and voltages into the human body defined in the standards for human health Charging To prevent potential battery damage during storage charge your charger every 12 months Use of third party accessories Only use accessories transducers or cables supplied by the manufacturer Non original accessories may resul...

Page 26: ...r The charger did not have enough time to turn the hearing aids ON before they were removed from the charger Two charger LEDs show ORANGE blinks The hearing aid or charger s temperature is too cold or too warm Three charger LEDs show ORANGE blinks System error The charger LEDs remain turned OFF when the charger is connected to power The charger is not charging ...

Page 27: ...aring aids ON manually Move the charger and hearing aid to a location with a temperature between 5 C and 38 C 41 F and 100 F Contact your hearing care professional Verify that the power plug is correctly connected Ensure that the power source delivers sufficient output for your charger Continues on next page ...

Page 28: ...emains turned OFF when the hearing aid is placed in the charger The charger is not turned ON The hearing aid or charger s temperature is either too warm or too cold Charging is incomplete The room temperature exceeds 35 C 95 F which extends the charging time The charger has stopped charging to protect the battery The hearing aid is not correctly seated in the charger The hearing aid LED blinks ORA...

Page 29: ... charger during this process Verify that the charger power plug is correctly connected or the power bank has enough battery Move the charger and hearing aid to a location with a temperature between 5 C and 38 C 41 F and 100 F Reinsert the hearing aid into the charger This completes the charging within approximately 15 minutes Check the charging ports for foreign objects Contact your hearing care p...

Page 30: ...Atmospheric pressure 700 hPa to 1060 hPa Transportation and storage conditions Temperature and humidity shall not exceed the below limits for extended periods during transportation and storage Temperature 20 C to 60 C 4 F to 140 F Humidity 5 to 93 non condensing For information about your hearing aid s conditions of use see your hearing aid s instructions for use ...

Page 31: ...OT covered by the international warranty and may void it The above international warranty does not affect any legal rights that you might have under applicable national legislation governing the sale of consumer goods in the country where you have bought your device Your hearing care professional may also have issued a warranty that goes beyond the clauses of this international warranty Please con...

Page 32: ..._________________________ Hearing care professional s address ________________________________________ Hearing care professional s phone _________________________________________ Purchase date _________________________________________________________ Warranty period ________________ Month _________________________________ Model ________________________ Serial no _______________________________ ...

Page 33: ...E mark The device complies with all required EU regulations and directives Electronic waste WEEE Recycle hearing aids accessories or batteries according to local regulations Hearing aid users can also return electronic waste to their hearing care professional for disposal Electronic equipment covered by Directive 2012 19 EU on waste and electrical equipment WEEE Regulatory Compliance Mark RCM The ...

Page 34: ...r s catalogue number so that the medical device can be identified Serial number Indicates the manufacturer s serial number so that a specific medical device can be identified Medical Device The device is a medical device Nature of supply voltage Indicates that the nature of the device s power supply voltage shall be DC direct current Battery recycling symbol Li ion Battery recycling symbol Tempera...

Page 35: ...35 Humidity limitation Indicates the range of humidity to which the medical device can be safely exposed FW Firmware version used in the device ...

Page 36: ...acturer may not ensure compliance with FCC and Innovation Science and Economic Development Canada s RF exposure guidelines User information This equipment has been tested and found to comply with the limits pursuant to part 18 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can ...

Page 37: ...h can be determined by turning the equipment OFF and ON the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the equipment Increase the separation between the equipment Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment ...

Page 38: ...e handled according to local regulations This medical device complies with the Medical Device Regulation EU 2017 745 Declaration of Conformity is available at the headquarters Sonic Innovations Inc 2501 Cottontail Lane Somerset NJ 08873 USA www sonici com doc SBO Hearing A S Denmark 233842 UK ...

Page 39: ......

Page 40: ...2021 05 06 233842 UK subject to change 0000233842000001 ...

Reviews: