Summary of Contents for SH ARC-ISA

Page 1: ......

Page 2: ...Handbuch Manual 2 ...

Page 3: ...llen 13 4 1 Koaxiale Schnittstelle K KR auch bei Hub 13 4 2 RS 485 EIA 485 Schnittstelle KR R auch bei Hub 13 4 3 RS485AC Schnittstelle RS485AC nur bei Hub 14 4 4 Twisted Pair Schnittstelle TWP nur bei Hub 15 4 5 LWL Schnittstellen LWLSMA LWLST LWLTOS nur bei Hub 15 5 Was tun bei Problemen 16 6 Safety Instructions 19 6 1 Warnings and Instructions 19 6 2 Installation 19 6 3 To ensure Electro magnet...

Page 4: ...ub 27 9 2 RS 485 EIA 485 Interface R also with hub 27 9 3 RS485AC Interface RS485AC with hub only 28 9 4 Twisted pair Interface TWP with hub only 29 9 5 Fiber Optic Interfaces LWLST LWLSMA LWLTOS with hub only 29 10 Technical Specifications 30 10 2 CE Declaration of Conformity 33 10 3 Contact 33 10 4 Warranty 33 10 5 Support 33 10 6 Order information 34 10 7 Literature 35 4 ...

Page 5: ...rf nur in PCs mit Gehäusen gemäß EN 60950 1 eingebaut und betrieben werden 1 3 Elektromagnetische Verträglichkeit a An den ARCNET Anschlüssen dürfen nur geschirmte Kabel mit geschirmten Steckern angeschlossen werden b Es dürfen nur Bitraten verwendet werden die von SOHARD für das gewählte Übertragungsverfahren spezifiziert sind c Bei modularen Geräten dürfen nur originale Schnittstellenmodule von ...

Page 6: ...arten sind als einfache ARCNET Knoten mit koaxialer sowie koaxialer und RS 485 Schnittstelle von denen jeweils nur eine betrieben werden darf ausgeführt Letztere verfügt außerdem über einen Timer Baustein Außerdem gibt es Karten mit 5 fach Hub Controllern bei denen je ein Kanal vom PC und der Koaxial RS 485 Schnittstelle belegt wird An die verbleibenden Kanäle können bis zu drei beliebige ARCNET S...

Page 7: ...esem Wert möglichst gut entsprechen damit keine Reflexionen auftreten DIP Schalter S3 Schalter 3 Schalter 4 Funktion ON ON Leitungsabschluss für RS485 aktiviert OFF OFF Kein Leitungsabschluss für RS485 aktiviert ON OFF unzulässig OFF ON unzulässig S1 und S2 werden nicht verwendet Bei den Lichtwellenleiter Schnittstellenmodulen kann die Sendeleistung in vier Stufen Very low low Werkseinstellung med...

Page 8: ...1 0 120hex 0001 0010 0000 binär Mit den Adressleitungen A00 A03 werden die einzelnen Register auf der Karte adressiert 3 2 Interrupt Einstellung Über die Jumperleiste wird der verwendete Interrupt ausgewählt Die Zuordnung der einzelnen Jumper zu den Interrupts ist aus der Beschriftung auf der Karte ersichtlich Achten Sie darauf dass dieser Interrupt von keiner anderen Karte im PC verwendet wird da...

Page 9: ...nfiguration IO Basis 7 COM20022 TENTID NODEID SETUP IO Basis 8 Timer 82C54 Counter 0 IO Basis 9 Timer 82C54 Counter 1 IO Basis 10 Timer 82C54 Counter 2 IO Basis 11 Timer 82C54 Control Word Register IO Basis 12 reserviert IO Basis 13 reserviert IO Basis 14 reserviert IO Basis 15 reserviert Die Funktion der Register ist den Datenblättern zum COM20022 2 bzw zum 82C54 4 zu entnehmen 3 4 Bitrateneinste...

Page 10: ... Module müssen bei der SH ARC PC104 und den HUB Varianten mit dem Flachbandkabel des Netzwerk Schnittstellen Moduls an den passenden Steckverbinder auf der Karte angeschlossen werden 3 6 Gerätetreiber und alternative Zugriffsmöglichkeiten Gerätetreiber ARCNET Treiber und Beschreibungen für ihre Installation und Verwendung finden Sie auf der mitgelieferten CD Bitte sehen auf unserer Website www soh...

Page 11: ...iffsart Der COM20022 wird im Non Multiplexed Mode betrieben Die Umschaltung in diesen Modus erfolgt nach Reset durch einige Dummy Zugriffe auf den Baustein 2 In der Regel erfolgt die korrekte Einstellung bereits durch Zugriffe des PC auf andere I O Einheiten wie z B Grafikkarte oder serielle Schnittstellen Wir empfehlen dennoch in der Treibersoftware diese Zugriffe durchzuführen Der COM20022 muss ...

Page 12: ...n die KOAX Schnittstellenmodule nicht angesteuert Gelb Receive Die LED zeigt Aktivität auf dem ARCNET Empfangskanal an Das Signal wird mittels eines digitalen Monoflops verlängert und so sichtbar gemacht Da die Schnittstellen das gesendete Signal auch wieder empfangen wird die LED auch durch das Sendesignal aktiviert Wenn das ARCNET stabil läuft leuchtet die LED kontinuierlich Wenn Rekonfiguration...

Page 13: ...chkeit EMV muss das verwendete Kabel über einen Schirm verfügen der möglichst niederimpedant mit dem Gehäuse des D Sub Steckers verbunden werden muss Anschluss D Sub Buchse 9 polig Steckerbelegung Pin Bezeichn Bedeutung 1 5 GND_RS Bezugspotential Masse Versorgungsspannung 3 DATA A Datenleitung A 4 DATA B Datenleitung B 2 6 8 NC Reserviert 9 5V_RS Galvanisch getrennte 5 Volt für RS 485 Schnittstell...

Page 14: ...netischen Verträglichkeit EMV muss das verwendete Kabel über einen Schirm verfügen der möglichst niederimpedant mit dem Steckergehäuse verbunden werden muss Anschluss RJ45 Buchse Steckerbelegung Pin Bezeich Bedeutung 4 DATA positive Datenleitung 5 DATA negative Datenleitung 1 3 6 9 unbeschaltet Reserviert 14 RS485 Transceiver Pin3 Sub D Connector Pin4 Sub D Connector 240 Ohm 240 Ohm 150 Ohm S1 S2 ...

Page 15: ...legung Pin Transceiver Pin Bedeutung 4 PH_A Datenleitung 5 PH_B Datenleitung 1 3 6 9 unbeschaltet Reserviert 4 5 LWL Schnittstellen LWLSMA LWLST LWLTOS nur bei Hub Anschluss LWLST 2 ST BFOC Buchsen je eine für Senden und Empfangen TX muss mit RX bzw RX mit TX der Gegenstelle verbunden werden Anschluss LWLSMA 2 FSMA Buchsen je eine für Senden und Empfangen TX muss mit RX bzw RX mit TX der Gegenstel...

Page 16: ...als 2 5 Mbit s Der COM20022 befindet sich im Backplane Modus Hub Funktion nicht bestückt Hub funktioniert nach Einschalten des PC nicht Mögliche Ursachen Wenn der optionale Hub Chip bestückt ist wird nach Reset oder dem Einschalten die Defaultbitrate Dip Switch S2 eingestellt Diese wird überschrieben wenn der Arcnetcontroller von der Software initialisiert wird Wenn die beiden Bitraten unterschied...

Page 17: ...ber es werden falsche Daten übertragen Mögliche Ursache Der COM20022 wird im 16 Bit Modus 2 betrieben Da die Karte über einen 8 Bit Datenbus verfügt wird in diesem Fall jedes zweite Byte falsch übertragen Abhilfe COM20022 im 8 Bit Modus betreiben 17 ...

Page 18: ...Handbuch Manual 18 ...

Page 19: ...nd operated within PCs with casings according to EN 60950 1 6 3 To ensure Electro magnetic compatibility a Only attach shielded cables and shielded connectors to the ARCNET connector b Only use bit rates which are specified by SOHARD for the actual transfer mode c Only use original interface modules by SOHARD for modular cards d Only use PC casings with intact and complete shielding Unused slots m...

Page 20: ...rds with also have a 5 channel hub controller on board One hub channel is connected to the PC another one to the coaxial RS 485 network interface Up to 3 external network interface modules any type can be attached to the remaining hub channels for connecting them to coaxial cable twisted pair cable or fiber optics 8 Starting Up 8 1 Switching bus termination and transmission power By default the te...

Page 21: ... SUB D plug socket must have a shield which should be connected to the plug housing at low impedance On fiber optical network interface modules the transmission power can be adjusted in 4 steps very low low default setting medium high 8 2 I O Address Setting Switch S1 is used for setting the I O address by which the card can be addressed The assignment of single switches to addresses is indicated ...

Page 22: ...rs are addressed on the card 8 3 Interrupt Setting The interrupt to be used is selected via the jumper panel The assignment of single jumpers to the interrupts is indicated on the card Please make sure that this interrupt is not used by another card within the PC since this might cause malfunctions and a damage to the card 8 4 Memory Occupancy The COM20022 occupies 8 bytes of ongoing addressable s...

Page 23: ...OM20022 Configuration IO Basis 7 COM20022 TENTID NODEID SETUP IO Basis 8 Timer 82C54 Counter 0 IO Basis 9 Timer 82C54 Counter 1 IO Basis 10 Timer 82C54 Counter 2 IO Basis 11 Timer 82C54 Control Word Register IO Basis 12 Reserved IO Basis 13 Reserved IO Basis 14 Reserved IO Basis 15 Reserved The function of the register can be taken from the data sheets of COM20022 2 or 82C54 4 8 5 Hub Bit Rate Set...

Page 24: ...b versions the flat ribbon cable of the external network interface modules must be connected to the matching connector on the card 8 7 Device drivers and alternative access Device drivers ARCNET driver and descriptions for their installation and usage are to be found on the enclosed CD Please refer to the section SH ARC ISA or SH ARC PC104 Downloads on our website www sohard de for the latest driv...

Page 25: ... rates 8 8 2 Access Mode The COM20022 is operated in the non multiplexed mode The switchover to this mode is effected by some dummy accesses 2 after reset As a rule the correct setting is already effected by accesses to the PC to other I O units such as graphics card or serial interfaces We nevertheless recommend to carry out these accesses in the driver software The COM20022 must be operated in t...

Page 26: ...sed Yellow Receive The LED indicates any activity on the ARCNET receiving channel The signal is prolonged and thus made visible by means of a digital monostable multivibrator As both the Coax and the RS485 interface receive the sent signal too the LED is also activated by the transmitting signal If the ARCNET runs in a stable state the LED is continuously active If reconfigurations 1 appear the LE...

Page 27: ...ro magnetic compatibility EMC the shield of the cable connected to the D sub DE9M plug must be solidly attached to the screen of the connector Connector type D sub DE9F socket Pin assigment Pin Marking Description 1 5 GND_RS Reference potential supply 3 DATA A Data line A 4 DATA B Data line B 2 6 8 NC reserved 9 5V_RS Isolated 5 V Supply for RS485 Interface The maximum current must not exceed 25 m...

Page 28: ...lity EMC the shield of the cable connected to the RJ45 plug must be solidly attached to the shield of the connector Connector type RJ45 socket Pin assignment Pin Marking Description 4 DATA Data line 5 DATA Data line 1 3 6 9 NC Reserved 28 RS485 Transceiver Pin3 Sub D Connector Pin4 Sub D Connector 240 Ohm 240 Ohm 150 Ohm S1 S2 5V RS485 GND RS485 RS485 Terminierung ...

Page 29: ...ansceiver Pin Description 4 PH_A Data line 5 PH_B Data line 1 3 6 9 NC Reserved 9 5 Fiber Optic Interfaces LWLST LWLSMA LWLTOS with hub only LWLST connectors 2 x ST BFOC bayonet for transmission and reception respectively Connect TX to RX and vice versa LWLSMA connectors 2 x FSMA threaded for transmission and reception respectively Connect TX to RX and vice versa TOSLINK connector TOSHIBA specific...

Page 30: ...ure Data rates 2 1 Logic protecting dipulse transceiver against invalid bit rate and transmission mode 19 531 39 063 78 125 156 25 312 5 625 kbit s 1 25 2 5 5 10 Mbit s 10 1 3 HUB optional type channels Special feature Data rates transmission rate max transmission delay TMC2005 3 1 SH ARC ISA HUB 5 3 of which for interface modules 2 internal SH ARC PC104 HUB 5 4 of which for interface modules 1int...

Page 31: ...evice housing 10 1 6 RS 485 EIA 485 Interface R Data rate Input threshold Polarity in idle state Line termination DC Biasing Differential voltage output Connector 19 5 kbit s 10 Mbit s 200 mV positive 115 ohm internal termination disabled by default 240 ohm 5 V 240 ohm 0 V biasing disabled by default min 3 0 V D sub DE9F socket Galvanic insulation between D sub pins and shield 10 1 7 RS485AC Inter...

Page 32: ...ower Peak power wavelength Connector Cabling 19 5 kbit s 2 5 Mbit s min 25 dBm max 9 2 dBm typ 14 dBm when coupled in 50 µm fiber four grades selectable very low low default medium high 820 nm LWLST 2 ST BFOC sockets LWLSMA 2 FSMA sockets Fiber types values in µm 50 125 or 62 5 125 or 100 140 10 1 10 Optic Fiber Interface TOSLINK LWLTOS Data rate Optical input power Peak output power Peak power wa...

Page 33: ...D Embedded Systems GmbH Wuerzburger Str 197 90766 Fuerth Germany Tel 49 0 911 97341 522 566 Order management Technical support Fax 49 0 911 97341 510 eMail info sohard de 10 4 Warranty Warranty is granted by SOHARD Embedded Systems according to our General Terms and Conditions 10 5 Support Read these instructions carefully before taking the device into operation Before contacting us please make su...

Page 34: ...odule type PC must be ordered separately 2 Bit rate is depending on selected interface module Interface module type PC104 must be ordered separately 10 6 1 Interface modules type PC Order name Bit rate Mbit s Signal Socket Cable type SH KOAX PC 2 5 sine dipulse BNC coaxial cable RG 62 SH LWLSMA PC 0 0195 2 5 Light FSMA multi mode fibers SH LWLST PC 0 0195 2 5 Light ST BFOC multi mode fibers SH LWL...

Page 35: ...TOS PC104 0 0195 2 5 Light TODX296 TOSLINK multi mode fibers SH RS485 PC104 0 0195 10 RS 485 D Sub twisted pair cable SH RS485AC PC104 2 5 10 RS 485 RJ45 twisted pair cable SH TWP PC104 2 5 sine dipulse RJ45 twisted pair cable 10 7 Literature Reference Document 1 ANSI ATA 878 1 Local Area Network Token Bus 2 5 Mbps ATA 1999 http www arcnet com 2 Data Sheet COM20022 smsc http www smsc com 3 Data Sh...