Summary of Contents for 7700

Page 1: ...7700 7701 7702 Bedienungsanleitung 2 Operating Instructions 13 Mode d emploi 23 Instrucciones de manejo 33 Modo de utilização 43 470_051_066_BA_7700_D_GB_F_E_P 05 2007 qxd 09 05 2007 11 20 Seite 1 ...

Page 2: ...ance has no power switch When the power plug is connected to the power sup ply and the scales the appliance is supplied with power When the appliance is switched off the OFF message appears in the display Appliances which have become moist due to a change in ambient temperature may only be switched on after they are completely dry Power supplies which have become moist may not be switched on at al...

Page 3: ...g the initial calibration process in production Further regular measuring inspection tests recalibration must be carried out by the calibration authori ties responsible in compliance with national regulations Repairs may only be carried out by a centre authorised by Soehnle using genuine spare parts Cleaning Before cleaning disconnect the appliance from the mains by removing the power plug from th...

Page 4: ...or replacement delivery not be successful the statutory provisions shall be valid The period of warranty shall be 2 years beginning on the day of purchase Please retain your receipt as a proof of purchase Should your scale require servicing please contact your dealer or Soehnle Customer Service No responsibility shall be accepted for damage caused through any of the following reasons Unsuitable or...

Page 5: ... office quoted place of initial calibration Symbol for EU calibration Calibration count Calibration counter The calibration count indicates how often the scale was calibrated The stored count must match the cali bration count printed on the adhesive label affixed to the calibration plug Calling up the calibration count Press key and hold and then press key Hold both keys for 3 seconds Press key tw...

Page 6: ... use rechargeable batteries Normal batteries will destroy the appliance 6 Set up the scales at the point of application Align 7700 and 7701 using a spirit level and ensure that the appliance is horizontal 7 Align the 7702 using the spirit level and the adju stable feet until it is horizontal During the weighing process secure the appliance using the thumbwheels on the adjustable feet The scale is ...

Page 7: ...les Press the key The scale is ready for net weighing Deleting tare weight The display shows the gross weight or 0 000 when unloaded Switching off This is immediately possible when the display is 0 In other cases depress the button for 3 seconds When the appliance is running off the mains power supply the message Off appears in the display Printer IT Sends the dataset to the printer or IT equipmen...

Page 8: ...nded functions The key can be programmed with the following functions Hold unit switch over BMI and special Dialysis function The standard function programmed is BMI You can make changes in User mode p 19 20 Press the function key Display e g 170 body height in cm Body height 170cm Press key until body height is correct Body height 170cm Press key until body height is correct Confirm by pressing D...

Page 9: ... for 5 seconds To call up the User mode position press the key Increment and decrement the User mode position Increment by pressing the key Decrement by pressing the key Switch to the Edit function by pressing the key Select the decade by pressing the key The active decade flashes Set the value of the User mode position move for ward by pressing the key Back by pressing the key Save the set value ...

Page 10: ...dstill Pressing On key Standstill Removing load Max value Pressing On key Max value Removing load Slave counter Pressing On key Slave counter Removing load 0 06 W Filter setting 0 1 2 3 4 Very rapid filter Rapid filter Normal filter Slow filter Very slow filter 2 07 W Printer 0 1 2 3 4 No printer Strip printer Label printer TSP800 IT Customer specific print image 1 1 08 W External alibi memory 0 1...

Page 11: ...tive values Place an object on the scale remove an object from the scale Activation is described on Pages 19 20 In case of other error mes sages please contact your SOEHNLE service Technical data Housing made of anodised aluminium Operated by means of a tactile keypad Desktop power supply input 230VAC 50Hz 60mA output 9VDC 0 3A Charge adapter optional input 100 240VAC 50 60Hz 0 3 A output charge c...

Page 12: ...net www soehnle professional com 470 051 066 D GB F E P Printed in Germany 05 2007 D Technische Änderungen vorbehalten GB Subject to technical modifications F Tous droits de modification technique réservés E Todas las modificaciones técnicas reservadas P Assunto às modificações técnicas 470_051_066_BA_7700_D_GB_F_E_P 05 2007 qxd 09 05 2007 16 09 Seite 52 ...