Страница 1: ...User Manual Rev 2 0 8047 SIZEWISE 06 23 2014 User Manual Envy Line G Series Non Powered Mattress System with Optional Control Unit TM ...

Страница 2: ...urface 10 Positioning the Patient 10 Prone Position 10 Bedpan Placement Removal 10 Removing the Patient from the Mattress Surface 11 Safety Tips 12 Seven Zones of Bed Rail Entrapment 12 Storage and Disposal 13 Mattress Cleaning Instructions 14 Approved Chemical List Extreme CARRFLEXTM Polycarbonate Polyurethane 17 Laundry Instructions 19 Control Unit Cleaning Instructions 20 Maintenance 21 Trouble...

Страница 3: ...CTION CLARIFICATION Warnings and Cautions Warnings Cautions This symbol is intended to alert the user to the presence of important operating maintenance or servicing instructions Disregarding a warning could result in patient and or user injury as well as damage to equipment Electrical Shock Hazard Warning This symbol is intended to alert the user to the presence of electrical shock hazards It is ...

Страница 4: ...rs The patient support surface fits any standard hospital bed The NP24 and NP12 consist of air cylinders that run laterally underneath the entire body and are contained in a foam cavity On top of the air cells is a viscoelastic foam comfort layer laminated to a either a foam comfort layer The heel section of the mattress is tapered to further reduce pressure for the sensitive heel area Both the ai...

Страница 5: ...e Mattress 7 X 48 X 80 17 5 cm X 122 cm X 203 cm 54 Wide Mattress 7 X 54 X 80 17 5 cm X 137 cm X 203 cm 60 Wide Mattress 7 X 60 X 80 17 5 cm X 152 cm X 203 cm Weight Capacity 32 Wide Mattress 500 lbs 227 kg 35 Wide Mattress 500 lbs 227 kg 39 Wide Mattress 750 lbs 340 kg 42 Wide Mattress 750 lbs 340 kg 48 Wide Mattress 1 000 lbs 454 kg 54 Wide Mattress 1 000 lbs 454 kg 60 Wide Mattress 1 000 lbs 45...

Страница 6: ...esistant to a wide variety of cleaning chemicals that are typically problematic with materials used in the medical industry concerning degradation Extreme CARRFLEX resists breakdown with disinfectants and cleaners based on Chlorine Alcohol Peroxide Quaternary Ammonium Chloramine and Phenol NP24 NP12 NP9 and NP4 Non Powered self adjusting mattress systems Control Unit optional Provides a 10 15 20 o...

Страница 7: ...r The bacteriostatic top fabric is fire resistant fluid proof tear resistant cleanable and replaceable It consists of either a nylon cover polycarbonate polyurethane cover or a 4 way stretchable cover Mattress Height The total pressure management surface height is 7 18 cm Friction Shear All cover choices serve to reduce friction and shear Replacement Mattress The mattress can be placed directly on...

Страница 8: ... Cleaning Instructions See table of Contents Warning or Safety Instructions relating to set up NOTE Use of the NP24 NP12 NP9 and NP4 is only one element of care in the prevention and treatment of pressure ulcers Frequent repositioning proper care routine skin assessment wound treatment and proper nutrition are but a few of the elements required in the prevention and treatment of pressure ulcers As...

Страница 9: ...ressure level are preset to the middle settings Select from the touch panel to adjust the cycle time and pressure level It is recommended to set the pressure level at a low setting 4 For quick deflation a Turn power OFF b Remove the hoses from the control unit 5 Low Pressure alarm a The Low Pressure alarm will sound if the mattress has not reached 30mmHg after 45 minutes when first turned on b Dur...

Страница 10: ... either Static or Alternate therapy mode Autofirm Quickly inflates mattress to maximum firmness Unit returns to previous setting after 30 minutes Cycle Time Press to change the cycle time Soft Press to decrease firmness to the mattress Firm Press to increase firmness to the mattress ...

Страница 11: ...ilitates the repositioning of the patient with less strain on the care provider When the patient has been repositioned press auto firm to return to the previous setting NOTE DO NOT leave a patient unattended on the mattress surface with the safety side rails in the down position When leaving a patient secure the safety side rails in the up position Make sure the safety side rails are high enough t...

Страница 12: ...NOTE Always remove the bedpan before entering the Alternating Pressure mode Removing the Patient from the Mattress Surface If the patient is to be removed with a lift and transfer set the control unit into Auto Firm mode Allow the mattress to firm and position the patient into the lift When the patient has exited the bed the control unit can be turned off If the patient can sit up and is mobile lo...

Страница 13: ...bed rail entrapment as serious injury can result These guidelines can be found on the FDA website When using an Air Therapy system the care provider is responsible for ensuring the mattress properly fits the bed frame It is also the care provider s ultimate decision whether or not to use bed rails with the patient Zone 1 Within the Rail Zone 2 Under the Rail Between the Rail Supports or Next to a ...

Страница 14: ...ies may affect EMC performance Unauthorized use of these items will void warranty and could result in patient and or user injury as well as damage to equipment or other property The use of cables or accessories other than those for which the blower was designed or tested can significantly degrade emissions and immunity performance DO NOT use the device if the power cord is cut frayed or loosely co...

Страница 15: ...le Rinsing of the support surface covers with clean water as the immediate step after the disinfection process is fundamental to extending the usable life of the covers NOTE Only the outer cover of the mattress requires cleaning and maintenance Disassembly of the support surface for maintenance of internal components is not recommended Do not use harsh solvents or cleaners Special care should be u...

Страница 16: ...2 These pre moistened wipes meet the CDC s recommendations for Clostridium difficile C diff bacteria after the manufacturer s recommended wet contact time 1 Perform hand hygiene using soap and warm water or hand sanitizer and then put on disposable gloves and eye protection 2 Use wipes to wipe the top and front of head footboards hand controls and cords side rails and mattress top cover making sur...

Страница 17: ...mover according to the manufacturer s recommendations 6 Rinse all surfaces of the mattress with fresh water and clean cloth to remove chemical and organic residue No Abrasives Abrasive cleaners and abrasive cleaning devices scouring sponges will dramatically reduce the life of any polyurethane surface Do Not Use Solvents Follow Dilution Recommendations One of the most significant errors in cleanin...

Страница 18: ...NER SUREHANDS ACCORDING TO MANUFACTURERS SPEC CIDAL DISINFECTANT CLEANER ACCORDING TO MANUFACTURERS SPEC CLINELL HAND SURFACE SANITIZER DISINFECTANCT ACCORDING TO MANUFACTURERS SPEC CLINELL UNIVERSAL SANITIZING WIPES ACCORDING TO MANUFACTURERS SPEC CLINELL DETERGENT WIPES ACCORDING TO MANUFACTURERS SPEC CLINELL SPORICIDAL WIPES ACCORDING TO MANUFACTURERS SPEC DISINFECTING WIPES ACCORDING TO MANUFA...

Страница 19: ...G TO MANUFACTURERS SPEC SANICARE TBX ACCORDING TO MANUFACTURERS SPEC SANICARE DISINFECTANT WIPES BUCKEYE INTL ACCORDING TO MANUFACTURERS SPEC SODIUM HYPOCHLORITE 13000 PPM 1 3 SPRING CLEAN ECO LAB 5 SPRING CLEAN 1 20 WATER STERRIMATT PURE FOAM READY TO USE SUPER SANI CLOTH GERMICIDAL DISPOSABLE WIPES PDI ACCORDING TO MANUFACTURERS SPEC SURFACE SANITIZING WIPES ACCORDING TO MANUFACTURERS SPEC TERMI...

Страница 20: ...to the manufacturer s recommendations 2 Prepare a separate bucket of warm fresh water to be used for rinsing the equipment after cleaning disinfecting procedures are completed as instructed 3 All surfaces of the mattress are to be wiped using a coarse cloth dampened with the disinfectant prepared as directed by the manufacturer s recommendations to remove organic material and visible soil 4 Allow ...

Страница 21: ...solution prepared as directed by the manufacturer s recommendations to remove organic material and visible soil 6 Allow the control unit to remain wet with disinfectant solution for the manufacturer s recommended contact time 7 Rinse all surfaces of the control unit with fresh water and use a clean cloth to remove chemical and organic residue 8 After cleaning all surfaces are to be dried with a cl...

Страница 22: ...equipment safety checklist that can be used with the maintenance chart to maintain and service this product Inspect top cover for punctures rips tears or damage Inspect mattress base for punctures rips tears or damage Connect the control unit and verify proper operation if installed Ensure air filter is clean and properly installed into control unit if installed Ensure mattress is clean disinfecte...

Страница 23: ...oses are not punctured kinked or disconnected Check for proper connections from the hoses to the control unit Make sure they are secure Check air filters on back of control unit and clean if necessary Ensure CPR release is in the closed position If there is power loss Check the ON OFF switch Check power cord for any damage Unplug the Control Unit and check fuses located near the main ON OFF switch...

Страница 24: ...orkmanship on any RF welded air cell seam we will inspect and repair or replace the RF welded component at no charge The customer will be responsible for the expense of shipping or delivering the component to our factory as well as the cost of returning the replacement or repaired item We reserve the right to substitute materials if the original materials are no longer available This warranty cove...

Страница 25: ...24 User Assistance Information For questions or assistance with this product contact Sizewise at Sizewise 1600 Genessee Suite 950 Kansas City Missouri 64102 Phone 1 800 814 9389 ...

Страница 26: ...814 9389 sizewise net Sizewise and Sizewise Rentals are trademarks of Sizewise Rentals L L C All specifications equipment and prices are subject to change without notice Photos and drawings are representative of the products and may vary slightly from actual production models ...