Smoke Alarm User Manual 

Model number: GS519       

Ref

ST519

 

Thank you for purchasing our smoke  alarm. Please take a 

few minutes to read the user’s manual thoroughly and 

familiarize yourself and your family with its operation. And 

save it for future reference. 

 

 

 

 

 

 

 

 

 

Product Specifications: 

 

POWER

: 220-240V~/50Hz with 9V battery backup. 

 

ALARM VOLUME

: > 85dB(A) at 3 meters.   

 

ALARM SENSITIVITY

: 0.12~0.160dB/m 

 

SAME PUSH TEST BUTTON TO ACTIVATE 

SILENCE (HUSH) CONTROL

 

 

HUSH TIME: 

approx 8 minutes 

 

INTERCONNECTION: 

up to 40 detectors 

 

ALARM BATTERY LIFE: 

above one year 

 

OPERATION CURRENT:

<100mA 

 

BASE:

 built-in DC3V(CR123A) Lithium battery 

  (battery not replaceable) 

 

BASE BATTERY LIFE: 

above ten year 

 

WIRELES FREQUENCY:

433.42MHz 

 

WIRELESS INTERCONNECTION: 

up to 40 detectors 

 

WIRELESS  DISTANCE  :  >

100  meters in free field/ 

30m indoors   

 

COMPLY  WITH:

 AS3786:2014,

 

AS/NZS 4268 

 

SOUND PATTERN:

ISO8201(BI 0.5s -  pause 0.5s -  BI 

0.5s  -  pause 0.5s -  BI 0.5s -  pause 1.5s, with the RED 

LED flash, repeat this alarm pattern) 

NOTE:

 The total number of wired interconnections and 

wireless interconnections cannot exceed 40. 

Description: 

The  unit  is a photoelectric 220-240V~  with  9V DC  battery 

backup  smoke alarm  and the base built-in DC3V(CR123A) 

Lithium battery. With the photoelectric technology, it is more 

sensitive to detect slowly  smoldering  fires which general 

thick, black smoke, low  heat and may smolder for hours 

before burst  into flames. The smoke alarm  does  not contain 

the radioactive material which is harmless to the 

environment. 

The  smoke alarm  should be installed in every room (except 

the bathroom) and make  sure the people in  home be able to 

hear and respond to the alarm sound. For maximum 

protection you should fit an alarm in hallway between living 

areas and sleeping areas. Place the unit as near to the living 

areas as possible and ensure the alarm is audible when the 

bedrooms are occupied. 

Typical single storey dwelling with recommended: 

Install a smoke alarm on the ceiling inside each bedroom and 

in the hallway outside each separate sleeping area. If a 

bedroom area hallway more than 30 feet long, install a smoke 

alarm at each end. If there’s a basement: install a smoke 

alarm on the basement ceiling at the bottom of the stairwell. 

Typical multi-storey dwelling with recommended protection. 

Install a smoke alarm on the ceiling inside each bedroom and 

in the hallway outside each separate sleeping area. If a 

bedroom area hallway more than 30 feet long, install a smoke 

alarm at each end and install a smoke alarm at the top of first 

– to- second floor stairwell. 

Important Safety Information: 

1.

 

The test button accurately tests smoke alarm functions. Do 

not use any other test method. Test smoke alarm weekly to 

ensure proper operation. 

2.

 

When the smoke alarm is alarming, if you  sure it isn't a 

really alarm, open windows or fan the air around smoke 

alarm to silence it. 

3.

 

The apparatus shall not  be exposed to dripping or 

splashing and that no objects filled with liquids, such  as 

vases, shall be placed on the apparatus. 

4.

 

A non-pure sinusoidal power sources  is not suitable for 

this smoke alarm (e.g. derived from square-wave 

invertors). 

5.

 

This smoke alarm is powered by 220-240V~. The  source 

power is danger to human body. The smoke alarm should 

be installed only by a licensed, qualified electrician. 

Observe and follow all local and national electrical and 

building codes for installation. 

6.

 

This smoke alarm  is designed to be used inside a single 

family only. In multifamily buildings, each individual 

living unit should have its own smoke alarms. Do not 

install in non-residential buildings. And this smoke alarm 

is not a substitute for a complete alarm system. 

7.

 

Install a smoke alarm in every room and on every level of 

the home. Smoke may not reach the smoke alarm for many 

Summary of Contents for GS519

Page 1: ... as near to the living areas as possible and ensure the alarm is audible when the bedrooms are occupied Typical single storey dwelling with recommended Install a smoke alarm on the ceiling inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway more than 30 feet long install a smoke alarm at each end If there s a basement install a smoke alarm on the ba...

Page 2: ...on it is possible that the smoke alarm may fail at any time For this reason you must test the smoke alarm weekly and replace unit after 10 years Battery Specification Voltage DC 9V Alkaline Carbon Zinc Lithium battery Gold Peak GP1604S Carbon Zinc Battery Gold Peak GP1604A Alkaline Battery Raymax 6LR61 Alkaline Battery EVE CR9V P Lithium battery Voltage DC 3V Lithium battery GP Energy CR123A Lithi...

Page 3: ...ill flash every 8 seconds indicating the smoke alarm is in the alarm silencer Hush mode NOTE WEEKLY TESTING IS REQUIERED Alarm silence hush mode When you press same Test button for at least 5 seconds or until the unit sounds to active silence control the alarm will enter HUSH mode for approx 8 minutes Smoke alarms are designed to minimize false alarms Combustion particles from cooking may set off ...

Page 4: ...op approximately after 20 seconds has elapsed Note GS519 GS517E and GS518E can be interconnected Trouble shooting Problem Cause and Remedy The green LED does not light when AC power supply 1 Check the AC terminal and the power cord is properly connected to the smoke alarm 2 If the problem still exists please it return to your retailer 3 If the unit is out of warranty please replace another new ala...

Page 5: ... not to open the door if the door is hot Teach household members to crawl along the floor to stay below dangerous smoke fumes and gases Practice a fire drill at least every six months including fire drills at night Ensure that small children hear the alarm and wake when it sounds They must wake up in order to execute the escape plan Practice allows all occupants to test your plan before an emergen...

Page 6: ...ween 500mm and 1500mm from the highest point of the ceiling See Diagram 5 For single floor plan and multiple floor plan please refer to Diagram 6 Diagram 6 Wiring Instructions The appropriate power source is 220 240V single phase supplied When install or remove the smoke alarm you must turn off the AC power to ensure safety Connecting wires are recommended to use a cross sectional area from 0 8 mm...

Page 7: ... should be lit when the alarm is operating from AC power Test smoke alarm using test button The alarm will sound 3 short beeps 1 5 seconds pause Then repeat it until release the button WARNING To prevent injury this unit must be securely attached to ceiling in accordance with the installation instructions Service and Warranty Company warrants to the original consumer Purchase each new smoke alarm ...