Page 1: ...User Manual TC620 PID Firmware Version 4 17 Thermal IP camera with Perimeter Intrusion Detection...

Page 2: ...eir respective owners Liability Siqura accepts no liability for claims from third parties arising from improper use other than that stated in this manual Although considerable care has been taken to e...

Page 3: ...E MANAGER 25 6 4 CONNECT VIA UPNP 27 6 5 LOG ON TO THE UNIT 27 7 NAVIGATE THE WEBPAGES 29 7 1 MENU 29 7 2 ACCESS CONTROL 30 7 3 WEBPAGE ELEMENTS 30 8 VIEW LIVE VIDEO VIA BROWSER 31 8 1 ACTIVATE LIVE V...

Page 4: ...1 2 Image settings 53 12 1 3 Preview 55 12 2 VIDEO ENCODING OVERVIEW 56 12 3 ENCODER 1 57 12 3 1 Encoder Settings 57 12 3 2 Parameter value combinations 58 12 3 3 Constant Quality Mode configuration 5...

Page 5: ...rms 93 12 9 9 1 Alarm examples 94 12 10 PRIVACY MASK 95 13 AUDIO 97 13 1 ENABLE AUDIO 97 13 1 1 Input Settings 98 13 1 2 Output Settings 98 13 2 MAKE AUDIO CONNECTIONS 99 13 2 1 MX Transmitter Setting...

Page 6: ...EMENT 127 19 1 ASSOCIATE EVENTS WITH OUTPUT FACILITIES 127 19 2 CC OUTPUT 128 19 3 CC STREAM 128 19 4 FTP PUSH 129 19 5 RECORDER 129 20 DEVICE MANAGEMENT 131 20 1 GENERAL 131 20 1 1 Identification 131...

Page 7: ...2 LINUX 147 22 DATE AND TIME 149 22 1 DATE AND TIME 149 22 2 SNTP SETTINGS 150 22 3 ADVANCED 151 23 MULTICAST MULTI UNICAST AND PORT NUMBERS 153 23 1 MULTICAST 153 23 2 MULTI UNICASTING 154 23 3 PORT...

Page 8: ......

Page 9: ...d warnings in this manual Retain this manual with the original bill of sale for future reference and if necessary warranty service When unpacking your product check for missing or damaged items If any...

Page 10: ......

Page 11: ...equipment in a safe condition it is essential that both operating and servicing personnel follow standard safety procedures in addition to the safety precautions and warnings specified in this manual...

Page 12: ...been tested and found to meet the CE regulations relating to EMC and complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful in...

Page 13: ...extremely bright objects as this can damage the camera RoHS statement Global concerns over the health and environmental risks associated with the use of certain environmentally sensitive materials in...

Page 14: ......

Page 15: ...a sterile zone Through the web interface configuration of the ObjectR Advanced PID analytics is straightforward with either two detection lines or two detection zones To get the most out of the PID an...

Page 16: ...tection Thermal imaging It is possible to use standard CCTV cameras for video analytics but it requires experience and knowledge of the analytics to position them All sorts of distractions such as the...

Page 17: ...n an event the TC620 PID can push a JPG image to one or two FTP servers The event can be triggered externally by Perimeter Intrusion Detection VMD or Tamper Detect The TC620 PID can also periodically...

Page 18: ......

Page 19: ...rk video devices including automatic device discovery video streaming and intelligence metadata The TC620 PID fully supports ONVIF It has been tested to support ONVIF Profile S 4 2 OSA Siqura s Open S...

Page 20: ...ce Management page The SNMP Agent is MIB 2 compliant and supports versions 1 and 2c of the SNMP protocol Note The TC620 PID includes SNMP support for its tamper detect function A trap is sent when cam...

Page 21: ...e information which in turn will be used to control cameras and other devices in the transportation management system An electronic version of the MIB is available from a NEMA FTP site To get access t...

Page 22: ......

Page 23: ...tself is handled by the Real Time Transport Protocol RTP The TC620 PID supports video and audio streaming via UDP and TCP Use the following URL format to get a video stream into for example VLC or Qui...

Page 24: ...ver HTTP The TC620 PID reports to the client that it supports transfer over UDP and TCP The choice is made on the client side In VLC for example using a TCP connection can be forced Preferences Inputs...

Page 25: ...the PC and the TC620 PID 6 2 Connect via web browser To connect to the unit via your web browser 1 Open your web browser 2 Type the IP address of the TC620 PID in the address bar and then press ENTER...

Page 26: ...ces appear in the List View pane 2 If multiple network adapters exist select the appropriate adapter to scan the network that you wish to connect to 3 To perform a manual search click the Rescan butto...

Page 27: ...er Connect to a device via Windows Explorer For more information about UPnP see Auto Discovery Device Management chapter 6 5 Log on to the unit Users with a valid account for the TC620 PID can log on...

Page 28: ...ID Page 28 Access possible with default Admin account only default Admin password unchanged Access possible with the user account created for you default Admin password has been changed Connect dialog...

Page 29: ...ccess control 30 Webpage elements 30 7 1 Menu Use the menu on the left of each webpage to go to the other pages Click the option associated with the user or device settings you want to view or configu...

Page 30: ...ections are used to organise parameters and their values Buttons see below appear in sections with editable fields Tabs are used to organise page content Check boxes enable you to select features This...

Page 31: ...if PTZ functionality is implemented control the camera from your web browser In This Chapter Activate Live View 31 View live video 32 Use your browser for PTZ control 33 8 1 Activate Live View Live V...

Page 32: ...see Appendix Install a video player Refresh rate Available in Live View encoder mode Indicates the current refresh rate of the webpage Preview Shows live images from the video source as encoded by the...

Page 33: ...PID itself does not have PTZ functionality it can be mounted on a PTZ mounting bracket which can then be controlled from the TC620 PID s serial data port RS 4xx With a PTZ driver selected on the PTZ w...

Page 34: ...camera position 1 Click the appropriate number button s to enter the preset number 2 Adjust the position of the camera for the desired view 3 When satisfied with the position click SET Note The SET bu...

Page 35: ...a monitored by the TC620 PID is violated The PID video analytics uses configurable detection zones detection lines and object size with perspective correction to identify and track an object through t...

Page 36: ...g to degraded detection performance Also for example sky in the image causes the Automatic Gain Control AGC of the camera to adjust possibly degrading the image in which objects are to be detected 9 1...

Page 37: ...In both cases VDG Sense can be used for configuration and recording of the blob stream The VCA features available together with VDG Sense are Super fast forensic search on the recorded images 8x Mult...

Page 38: ...guration Configuring PID from the webpage involves the following steps 1 Enable web configuration 2 Select a detection type 3 Set up the detection layout 4 Configure zone and line properties 5 Configu...

Page 39: ...l input for object size The following overlays are available Detection zone trigger Detection line trigger Ignore line ignore Perspective helper Minimum object size filter helper Detection zone A dete...

Page 40: ...perspective shape is used to establish the perspective of the scene To make calculations of the perspective correction as accurate as possible it is best to draw it in a part of the scene that shows...

Page 41: ...um 1 ignore line Perspective Overlays a perspective shape over the preview Minimum object size filter Overlays a minimum object size filter shape over the preview To add a shape Click the respective b...

Page 42: ...xt menus You can use these settings as a filter to determine when an object triggers an event Right click a shape to open its context menu Detection zone Item Description Detect delay The time to elap...

Page 43: ...set here Type Touch Ignore time countdown starts when an object touches the ignore line Completely cover Ignore time countdown starts when an object completely covers the ignore line 9 1 4 6 Show dete...

Page 44: ...t you with this and with a variety of other tasks To upload a PID configuration file 1 In the PID section select Expert configuration 2 In the Upload section click Choose file or Browse 3 Browse and s...

Page 45: ...g or OK Stream state Description OK There is nothing wrong with the stream Note that if the video signal is removed from the video input on the encoder side the Decoder rx state is still reported as O...

Page 46: ...ot Not present No SD card detected 10 2 View measurements data Status page a snapshot with automatic page updating 10 2 1 General network and stream measurements The Measurements tab shows general mea...

Page 47: ...of the actual SD card size given under Edge Recording Specifics that is for example 24 GB of a 32 GB SD card This limit is to prevent slow read write speeds 10 2 3 FTP Push You can use the FTP Push d...

Page 48: ......

Page 49: ...the unit is in the 10 x x x range with a subnet mask of 255 0 0 0 Achieving initial communication with the unit requires that the network adapter of the browsing PC is set to the factory default subn...

Page 50: ...work Item Description DHCP enable Allows assigning of the IP address by a DHCP server instead of using static IP addressing Ethernet mode Transmission mode and speed Auto Autonegotiation default 10 HD...

Page 51: ...r camera setup video encoding on screen display video motion detection FTP push image quality tamper detect privacy masks and PID In This Chapter Thermal 52 Video encoding overview 56 Encoder 1 57 Enc...

Page 52: ...pending on the time of day weather conditions and ambient temperature White Hot Warmer objects are displayed in white or light shades Black or dark shades indicate colder objects Black Hot Warmer obje...

Page 53: ...nd to maintain reliable detection it must be calibrated at regular intervals The image freezes for a second during calibration Using the options in the Max calibration interval list you can control th...

Page 54: ...e click the Thermal tab When creating a custom profile it is possible to use an existing profile as a basis 2 In the Image profiles section click to open the profile list 3 Select the profile that com...

Page 55: ...mages and see the effect of the current settings Hide Preview Closes the preview This may improve webpage responsiveness Encoder The encoder handling the images seen in the preview Volume Encoder mode...

Page 56: ...eved using RTSP A total of six copies three per independent encoder can be transmitted to different unicast and or multicast destinations using Siqura s proprietary MX protocol The TC620 PID supports...

Page 57: ...gure its settings Video bit rate mode Controls variations in bit rates Constant quality Keeps the image quality constant with varying network load See Constant Quality Mode CQM configuration below for...

Page 58: ...ameter value combinations Set sensible combinations of video bit rate mode resolution GOP length and frame and bit rates When you set and save these values inappropriate value combinations are correct...

Page 59: ...For more information on port numbers see the Port Numbers section 4 Select Enable and then click Save Video Receiver Settings decoder side Receiver 1 enabled holding the encoder IP address and the dec...

Page 60: ...section Recommended setting 1 F models or 4 S models X resolution Variables that enable you to freely set picture resolution instead of using the resolution presets in the Encoder Settings section Y...

Page 61: ...ing blocking distortion Be aware however that applying the filter requires substantial processing power Deblocking filter alpha coefficient Set the alpha beta coefficients of the deblocking filter Ent...

Page 62: ...rolled streams and SAP streams should not exceed 25 Mbit s See the value for the Total tx bit rate parameter on the Measurements tab of the Status page The Stream bandwidth limit mechanism is disabled...

Page 63: ...cast traffic is permitted to pass through before expiring on the network RTP control mode Select the transport protocol to control the stream None No transport protocol selected FloodGuard Flooding pr...

Page 64: ...to 64 network service types can be defined RFC 2724 http www ietf org rfc rfc2474 txt describes the Differentiated Services DS field and the DiffServ Code Point See also the note on Differentiated Se...

Page 65: ...P address the media stream is to be sent to The address must be within the range defined by the Multicast IP range parameter Stream dest port The destination port number Default 1024 Stream DSCP field...

Page 66: ...ecify the Multicast IP range 5 Enter the Stream Destination IP address and the port number The IP address must be within the scope range displayed for the Multicast IP range parameter 6 Enter modify t...

Page 67: ...User data is preceded by the User data header 00 00 01 B2 0x00 0x00 0x01 0xB2 User data message For MJPEG these for the rest identical messages are inserted as comment field FF FE 0xFF 0xFE Size MSB S...

Page 68: ...e will be 0 Bit 2 for future use will be 0 Bit 3 for future use will be 0 Bit 4 for future use will be 0 Bit 5 Reserved for Audio present Bit 6 Fixed 1 Bit 7 Fixed 0 Status 3 CC status part 1 Bit 0 CC...

Page 69: ...the primary standard for video audio transport over multicast or unicast network services RTP does not provide guaranteed delivery but sequencing of the data makes it possible to detect missing packe...

Page 70: ...is enabled it opens a control receive port with the port number equal to its source port number 1 This port listens for control packets from the destination receiver When no FloodGuard packets come i...

Page 71: ...e settings edge recording may become impossible Warning Incorrect encoder settings for edge recording To configure settings for edge recording 1 Select Enable to enable the encoder 2 On the Profile li...

Page 72: ...72 Custom settings If you need to apply custom settings you can do so with the following restrictions Video bit rate mode always set to Constant bit rate GOP length 25 Bit rate 1000 kbit s Resolution...

Page 73: ...Description Enable All encoders are enabled by default Use this check box to disable re enable this specific encoder Video bit rate mode Controls variations in bit rates Constant quality Keeps the ima...

Page 74: ...rate divider Relates to the frame rate configured in the Encoder Settings section X resolution Variables that enable you to freely set picture resolution instead of using the resolution presets in th...

Page 75: ...rom the screen clear the Enable check box OSD text The text to be displayed Maximum 255 characters Text is displayed in a single line The number of characters visible on screen is determined by the fo...

Page 76: ...the slider or type a percentage X Position Variables that enable you to freely position the object instead of using the presets Drag the sliding buttons or enter a percentage When a preset has been se...

Page 77: ...y adjusts to text dimensions when a bar is rotated Video OSD Text 1 Advanced Font Management To upload a font 1 In the Font management section click Browse The Open dialog box displays 2 Browse to the...

Page 78: ...y position the object instead of using the presets Drag the sliding buttons or enter a percentage When a preset has been selected changing one of its defined parameters sets the Predefined positions b...

Page 79: ...maximum file size of 100 kB to the TC620 PID If necessary use a picture resize tool to reduce the file size To upload a graphic 1 In the Graphic Management section click Browse The Open dialog box di...

Page 80: ...s there These changes could be caused by motion or varying lighting for example Regions of less interest can be masked 12 7 1 VMD startup To start Video Motion Detection 1 On the Video page click the...

Page 81: ...tection levels local change is only detected if its level exceeds a certain value The sensitivity setting can be used to eliminate unwanted false triggering e g caused by background noise or constant...

Page 82: ...mask in the unit To delete a mask Press the Clear button Masking grid Item Description Brush Normal Allows grid elements to be accessed in 4 element groups Large Allows grid elements to be accessed i...

Page 83: ...e lower threshold The red one right picture extending past it since this threshold is set much lower 12 7 5 VMD alarm If movement is detected a module alarm VMD will be generated and sent out over the...

Page 84: ...or the frame rate divider frames are evaluated A VMD event becomes active when within the Event window the number of frames with motion exceeds a configurable value the Event window high mark After th...

Page 85: ...d when configured event occurs Event Off Image is posted when configured event ceases Event Changed Images are posted when configured event occurs or ceases Continuous Posting not associated with any...

Page 86: ...ociated with the TC620 PID You can assign a primary server and a secondary server Images are posted simultaneously to both the primary server and secondary server Video FTP Push Primary Server example...

Page 87: ...and troubleshoot FTP Push You can monitor FTP push on the Measurements tab of the Status page Measurements on this tab are continuously updated In the FTP Push section you can compare the number of i...

Page 88: ...for example It does so by comparing the current image to one or more reference images that were captured and stored earlier 12 9 2 Enable Tamper Detect Tamper Detect is disabled by default To enable T...

Page 89: ...tion click Configure Reference Images 2 Open the Reference image list and then select the image you want to create 3 Enter a descriptive name in the Label box 4 Enter a value in seconds for the Sampli...

Page 90: ...To edit the mask click on the grid that is put over the image One or more mask elements at and possibly around that position are produced Hold the standard mouse button and drag to brush i e mask larg...

Page 91: ...amount of camera movement that is allowed A position alarm is raised when the green circle is outside the crosshair centre For information about adjusting the amount of allowed camera movement see Po...

Page 92: ...arity specified here The lower the percentage entered for this parameter the fuzzier the match Match hysteresis This is the margin area where there is either a match or no match depending on the prece...

Page 93: ...detect functions A trap is sent when bad image quality or camera tampering has been detected and another one when the situation returns to normal This support requires a new SNMP MIB the OPTC VCA MIB...

Page 94: ...hough the current image still matches Reference 1 the changed camera position results in a position alarm Camera has moved further to the left Current image no longer matches any reference image resul...

Page 95: ...click the Privacy Mask tab 2 Under the preview click New A square mask appears as an overlay in the centre of the preview 3 Use the pointer to position and size the mask If desired click to select the...

Page 96: ......

Page 97: ...PID In This Chapter Enable audio 97 Make audio connections 99 Advanced 100 13 1 Enable audio Audio page Using the Enable check box at the top of the Audio page you can enable disable the entire audio...

Page 98: ...thout the need to press Save Input level VU meter to display audio input level Profile Preset combinations of settings A non standard setting configured through the Advanced Settings gives in the Prof...

Page 99: ...P address 172 22 250 131 would need similar settings that is it must hold the IP address of the TC620 PID as the destination and source Transmitters and receivers must be enabled in order for streamin...

Page 100: ...g 1 channel only the signal on the A1 input is used either line or microphone Sample rate Range 7850 48000 Allows you to enter custom settings other than those included in the Profile list in the Inpu...

Page 101: ...f the source that is the encoder on the other side of the connection The settings shown in the figure above are defaults used when receiving a stream of which the format cannot be determined for examp...

Page 102: ...affic is permitted to pass through before expiring on the network RTP control mode Select the transport protocol to control the stream None No transport protocol selected FloodGuard Flooding preventio...

Page 103: ...0 ms Timeout in ms before going to NoStream state RTP control mode Select the transport protocol to control the stream None No transport protocol selected FloodGuard Flooding prevention mechanism For...

Page 104: ...to classify network traffic and give precedence i e low latency guaranteed service to high priority traffic while offering best effort service to non critical traffic such as file transfers or web tra...

Page 105: ...will recognize the global scope and automatically listen for SAP announcements at the 224 2 127 254 multicast IP address The Administrative session scope allows you to enter a custom IP range within...

Page 106: ......

Page 107: ...In This Chapter General Settings 107 UART Settings 108 Make data connections 108 TCP Server Settings 109 Advanced 109 14 1 General Settings Data RS 422 485 page Item Description Wire mode RS 422 The R...

Page 108: ...error detection purposes 14 3 Make data connections Data RS 422 485 MX Transmitter Receiver Settings After selecting a data mode see General Settings and configuring the interface see UART Settings da...

Page 109: ...r port Range 0 65535 14 5 Advanced Important If in doubt about these settings do not change the default values 14 5 1 RS 4xx Settings RS 422 485 Advanced RS 4xx Settings For details about data words a...

Page 110: ...kets with a small payload low latency versus fewer packets with a large payload higher latency At lower bit rates a need for smoother PTZ may also require modification of these low level settings Note...

Page 111: ...Connection priority Parameter intended for use with MX Software Development Kit MX SDK Reorder buffer size Used to reorder incoming packets Stream fail delay Range 0 10000 ms Default 300 ms Timeout i...

Page 112: ......

Page 113: ...Input Settings 114 Make contact closure connections 114 Advanced 115 15 1 CC channels CC status and alarms CC Streams page CC channels The contact closure channels of the TC620 PID each capable of tr...

Page 114: ...and can be caught separately by application software Alternatively application software can poll the TC620 PID and check for the module alarm Stream alarms link alarms in the modules at both link ends...

Page 115: ...1 CC Streams Advanced Receiver 1 Item Description Source port filter Can be used to filter incoming data traffic With multiple signals sent to the same IP address and destination port number Source p...

Page 116: ......

Page 117: ...ontrol panel is available on the Live Video page This chapter explains how to enable PTZ control upload and remove PTZ drivers and configure data settings In This Chapter Enable PTZ control 117 Upload...

Page 118: ...ailable drivers in the PTZ Driver Management and Camera Settings sections To remove a PTZ driver 1 In the PTZ Driver Management section select the driver you wish to remove 2 Click the Del button 16 3...

Page 119: ...certificate 120 Self signed certificate 121 Open a secure connection 121 17 1 HTTPS Security page Secure connections An HTTPS connection is a standard HTTP connection on top of an SSL TLS connection...

Page 120: ...ified in the Common name text box Validity days The valid period in days of the certificate Default 365 Common name The name of the entity to be certified by the certificate E mail address The contact...

Page 121: ...as described above 2 Click Create self signed certificate 17 5 Open a secure connection With a security certificate installed you can establish a secure connection To enable HTTPS and open a secure co...

Page 122: ......

Page 123: ...unpingable Edge recording makes it possible to record and store video locally that is at the TC620 PID To prevent loss of video when the connection to a central network video recorder or VMS sytem is...

Page 124: ...ording status reported as pending is an indication that the encoder used for edge recording is either not enabled or not correctly configured for edge recording Edge recording continues until the devi...

Page 125: ...y available for edge recording is limited to 75 of the actual SD card size that is for example 24 GB of a 32 GB SD card This limit is to prevent slow read write speeds When the SD card is full recordi...

Page 126: ......

Page 127: ...lities 127 CC Output 128 CC Stream 128 FTP Push 129 Recorder 129 19 1 Associate events with output facilities Event Management On the Event Management page you can configure how the TC620 PID is to ha...

Page 128: ...pen or active closed Active one or more of the selected inputs is true Inactive none of the selected inputs is true 19 3 CC Stream Event Management CC Stream 1 Item Description Available inputs List o...

Page 129: ...an FTP push Selected inputs On selection of multiple inputs the inputs are connected with a logical OR Any one will cause an image upload to the FTP server FTP push status Inactive open or active clos...

Page 130: ...iggers for edge recording Selected inputs On selection of multiple inputs the inputs are connected with a logical OR Any one will trigger edge recording FTP push status Inactive open or active closed...

Page 131: ...enable support for Siqura s MX protocol Auto Discovery and ONVIF You can also upgrade downgrade the embedded firmware back up and restore a configuration and reboot the TC620 PID from this page In Thi...

Page 132: ...pper pane of the web pages Label 2 Title pane with Label 1 value 20 1 3 Advanced Device Management General Advanced 20 1 3 1 Alarm Settings Item Description Board temperature alarm A notification is i...

Page 133: ...pens in Notepad may prove useful when you are troubleshooting issues 20 2 2 Syslog settings Syslog is a standard which allows devices to send event notification messages over IP networks to event mess...

Page 134: ...SNMP Communities The community strings names which can be regarded as passwords in the SNMP Communities section must conform to those configured in the SNMP manager Often these are public mainly used...

Page 135: ...ation IP port are required fields Item Description Version The SNMP version used Destination IP port The IP address associated with the manager program and the destination port 162 is the default port...

Page 136: ...ou from upgrading the TC620 PID firmware through the MX Firmware Upgrade Tool application 20 4 2 MX Notifications Item Description IP address With 255 255 255 255 as the IP address for the manager the...

Page 137: ...r presence and services to a control point on the network Control points can search for devices on the network A discovery message is exchanged containing a few essential specifics about the devices e...

Page 138: ...operability of cameras codecs and VMS and similar systems of different brands and manufacturers by standardising the discovery management control and other interfaces between them The ONVIF architectu...

Page 139: ...ion This section offers information on the currently active firmware version 20 7 3 Upgrade This section of the webpage enables you to upgrade the firmware residing in the upgrade image area Important...

Page 140: ...e same time However only one request can be handled at a time The later request receives this error message Invalid firmware file The unit performs a number of checks to determine the validity of the...

Page 141: ...tory version 4 To confirm the removal of the upgraded firmware press Continue Progress of the downgrade process is shown under the Revert to factory version button Important Do not leave the Firmware...

Page 142: ...em Description Keep current network settings Select to preserve the current network settings when you restore a backed up TC620 PID configuration Keep current SSL certificates Select to preserve curre...

Page 143: ...be set by the user with the exception of the network settings Reset to factory settings incl network settings A complete reset which will restore the unit s settings including the IP address subnet m...

Page 144: ......

Page 145: ...rol The TC620 PID has three levels of access to the internal web pages User groups are Administrators Operators and Viewers Do not use the name of one of these groups as a user name Out of the box the...

Page 146: ...the settings into the unit click Add The user is added to the User List Adding a user To edit a user 1 On the User Management page open the Web Access tab 2 Select the user name from the User List an...

Page 147: ...t all times The root password which is required when logging on to Linux with root authority is 1234 by default Using the Linux tab an Admin can set or change the root password Should you have forgott...

Page 148: ......

Page 149: ...Save to make your changes permanent On screen date time display can be activated on the OSD tab of the Video page The on screen position and colour of the text are governed by the relevant OSD setting...

Page 150: ...ally with the aid of a Simple Network Time Protocol SNTP server If enabled the SNTP server is queried automatically by the internal clocks with a configurable time interval To set up the TC620 PID for...

Page 151: ...zone and DST settings you can go to Advanced Settings and enter custom settings there You may for example need to set a time zone which is not included in the list Once you have saved a custom value...

Page 152: ......

Page 153: ...it is compounded by the density of the UDP streams used Multicast group A multicast group is used by the source that is the TC620 PID and the receivers to send and receive multicast messages To defin...

Page 154: ...signal to carry from the encoder When such a destination is removed the source also stops sending the corresponding stream If the input channel of a destination is disabled without disabling the sourc...

Page 155: ...ed in your web browser To enable JavaScript in Internet Explorer 1 On the Tools menu click Internet Options 2 On the Security tab click the Internet globe icon and then click Custom level 3 On the Set...

Page 156: ......

Page 157: ...ble click a device to open its webpages To enable UPnP in Windows 7 1 In Control Panel click Network and Sharing Center 2 In the left pane click Change advanced sharing settings 3 Under the relevant n...

Page 158: ......

Page 159: ...PID In This Chapter Download video player software 159 Install QuickTime 159 Install VLC 160 Download video player software The TC620 PID supports QuickTime and VLC If neither is detected when you att...

Page 160: ...n successfully tested with VLC v2 1 0 VLC and Windows 7 To configure VLC media player settings when running this plug in on a Windows 7 PC 1 Open the VLC media player 2 On the Tools menu click Prefere...

Page 161: ...ory parts and some of the optional parts see table below of the NTCIP CCTV specification as laid down in the NTCIP 1205 2001 v01 08 document This means that in terms of section 4 of this document the...

Page 162: ...ow labelStartColumn labelStatus labelLocationLabel labelEnableTextDisplay Motion control The Motion Control group defines the variables that provide PTZ control For details refer to NTCIP 1205 Conform...

Reviews: