background image

 

 

 

Building Technologies 

Fire safety and security products 

 

 
 
 
 
 
 
 
 

 
 
 
 
 

 

 
 

 
 
 
 

FDT181 Heat Detector  
Product Manual 

 
 
 

Overview  

 

The heat detector

 

FDT181 is an intelligent detector. It is used for early fire detection 

inside a building and particularly suitable for use in places where other types of 
detectors are not suitable because they can be misled by the smoke, dust and gas 
generated during work there. 

Characteristics  

 

  With built-in CPU, signals received are processed by intelligent algorithm 

  Two operation modes: A2S/A2R 

  Automatically address setting without encoder setting or  DIP switch 

  All-around visible alarm indicator 

  Resistant to environment and interference factors such as humidity, electro-magnetic 

interference, corrosive and vibration. 

  Communication via FD18-BUS, polarity free connection 

 

Sticker Method

 easy for commissioning 

Functions  

 

  The detection behavior of the detectors is influenced by the parameter sets, so that it 

can be specifically adjusted to the fire phenomena and environmental conditions to 
be expected in the environment to be monitored 

  Unique ID of each detector, controller  can identify the detector type according to the 

ID and assign address 

Summary of Contents for FDT181

Page 1: ...o operation modes A2S A2R Automatically address setting without encoder setting or DIP switch All around visible alarm indicator Resistant to environment and interference factors such as humidity electro magnetic interference corrosive and vibration Communication via FD18 BUS polarity free connection Sticker Method easy for commissioning Functions The detection behavior of the detectors is influen...

Page 2: ...its operating status See table Detector Indicator Normal Off Locate Test Flashing Alarm Steady on Installation l Easy and time saving mounting Install the base and finish the wiring during the construction phase 1 Point the retaining nest to the positioning pointer and insert it into the base 2 Turn it clock wisely until it stops Uninstallation 1 Turn it counterclockwisely until it stops 2 Pull th...

Page 3: ...ditions Long term auxiliary detectors should be stored with plastic bag Carry out heat test each year Teconical data Operating voltage 12 32 VDC Operating current quiescent 0 26 mA Activation current 1 2 mA Operating temperature 10 50 C Storage temperature 20 75 C Humidity 96 40 2 Communication protocol FD18 BUS Color White RAL 9010 Protection category GB4208 93 IP44 Details for ordering Type Mate...

Page 4: ...Xinxi Road Shangdi Information Industry Base Haidian District Beijing 100085 China Tel 10 6296 2255 Fax 10 6298 7387 www sbt siemens com Data and design subject to change without notice Doc No A6V10214490_a_en_ Version a Manual FD18 Edition 03 2010 ...

Page 5: ...izSoft PDF Password Remover With the trial version only the first 5 pages of each file can be exported To get all the pages exported you need to purchase the software from http www anypdftools com buy buy pdf password remover html ...

Reviews: