background image

 

 
 
 
 
 
 
 
 
 
 
 

 

 

Titan Strobe BLAZE                 V1 

Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands 

ENGLISH 

Ordercode: 40297 

MANUAL 

Summary of Contents for Titan Strobe blaze

Page 1: ...Titan Strobe BLAZE V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands ENGLISH Ordercode 40297 MANUAL ...

Page 2: ...el 11 Control Mode 11 DMX Addressing 11 Menu Overview 12 Main Menu Options 13 1 Operation Modes 13 2 DMX Address DMX Settings 13 3 Channel Modes DMX Settings 13 4 DMX Error DMX Settings 14 5 Strobe Brightness Manual Mode 14 6 Strobe Frequency Manual Mode 14 7 LED Master Dimmer Manual Mode 14 8 LED Color Macros Manual Mode 14 9 LED Color Switch Flow Speed Manual Mode 14 10 LED Color Switch Color Fl...

Page 3: ...operating temperatures than in ideal or singular optimum conditions For this reason when all color LEDs are used at their fullest intensity life of the LEDs is significantly reduced If improving the lifespan is of higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of overall projection intensity Safety Instructions E...

Page 4: ...ating Always allow free air space of at least 50 cm around the unit for ventilation Always disconnect power from the mains when device is not used before cleaning or when replacing lamp Only handle the power cord by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher ...

Page 5: ... shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the Titan Strobe is lowered from the ceiling or high joists professional trussing systems hav...

Page 6: ...oper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your address 03 Your phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defec...

Page 7: ...omplete package for all professional lighting operators Input voltage 240V AC 50 60Hz Power consumption 1800W Light source strobe Xenon 1500W tube Light source blaze 2 x RGB LED strip Light output 120 000 lm Strobe linear 1 15Hz Strobe blinder 25Hz Control Manual Master Slave DMX 512 RDM DMX control via standard DMX controller DMX channels 3 5 9 channels Circuit breaker 16A Color Black Housing Met...

Page 8: ...power supply before changing lamps The lamp has to be replaced when it is damaged or deformed due to the heat Do not install lamps of higher wattage Lamps of higher wattage generate temperatures which the device was not designed for Damages caused by non observance are not subject to warranty DANGEROUS Leave the device disconnected for 15 minutes before opening Otherwise you risk electrocution 01 ...

Page 9: ...trobes Master Slave control 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Use a 3 pin 5 pin XLR cable to connect the Titan Strobe The pins 01 Earth 02 Signal 03 Signal 03 Link the units as shown in fig 03 Connect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the seco...

Page 10: ... Connect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug electric mains power cords into each unit s Pro power socket then plug the other end of the mains power cord into proper electric power supply sockets starting with the first unit Do not supply power before th...

Page 11: ... Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cables DAP Audio Basic microphone cable for al...

Page 12: ...ss of the third Titan Strobe should be 10 9 19 019 etc Please be sure that you do not have any overlapping channels in order to control each Titan Strobe correctly If two or more Titan Strobes are addressed similarly they will work similarly Controlling After having addressed all Titan Strobe fixtures you may now start operating these via your lighting controller Note After switching on the Titan ...

Page 13: ...12 Ordercode 40297 Titan Strobe BLAZE Menu Overview ...

Page 14: ...ss the OK button to confirm your choice 05 If you have chosen DMX settings read the instructions concerning the menus 2 3 and 4 pages 13 14 06 If you have chosen Manual mode read the instructions concerning the menus 5 11 pages 14 15 2 DMX Address DMX Settings With this menu you can set the DMX address 01 Press the UP DOWN buttons until the display shows ADDRESS 02 Press the OK button to open the ...

Page 15: ...the display shows STROBE_S 02 Press the OK button to open the menu 03 Press the UP DOWN buttons to set the strobe frequency The adjustment range is between from low to high frequency and OFF 04 Press the OK button to save changes 7 LED Master Dimmer Manual Mode With this menu you can set the master dimmer of the LEDs 01 Press the UP DOWN buttons until the display shows C_MASTER 02 Press the OK but...

Page 16: ...s the OK button to open the menu 03 Press the UP DOWN buttons to set the strobe frequency The adjustment range is between from low to high frequency and OFF 04 Press the OK button to save changes DMX Channels 3 Channels Channel 1 Strobe dimmer 0 4 Not functional 5 255 From dark to brightest Channel 2 Strobe programs CH1 must be open 0 4 Not functional 5 127 Linear strobe from low to high frequency...

Page 17: ...requency 1 15Hz 130 159 Blinder 25Hz 160 189 Random flash 190 229 Lightning effect 230 255 Sync flash Channel 4 LED dimmer 0 255 From dark to brightest Channel 5 Color presets CH4 must be open 0 9 Not functional 10 19 Red 20 29 Orange 30 39 Yellow 40 49 Green 50 59 Cyan 60 69 Blue 70 79 Pink 80 89 Magenta 90 131 Color program 1 color switch from slow to fast 132 173 Color program 2 color switch fr...

Page 18: ...dark to brightest Channel 6 Green CH4 must be open CH8 must be closed 0 255 Gradual adjustment Green from dark to brightest Channel 7 Blue CH4 must be open CH8 must be closed 0 255 Gradual adjustment Blue from dark to brightest Channel 8 Color presets CH4 must be open 0 9 Not functional 10 19 Red 20 29 Orange 30 39 Yellow 40 49 Green 50 59 Cyan 60 69 Blue 70 79 Pink 80 89 Magenta 90 131 Color prog...

Page 19: ...an Disconnect electric power and then wipe the DMX and audio connections with a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power Changing the Lamp 01 Disconnect mains power supply 02 Follow directions for installing the lamp page 7 DANGEROUS Leave the device disconnected for 15 minutes before opening Otherwise you risk electrocution Replacing...

Page 20: ...ratically or not at all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing termination plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 12...

Page 21: ...ze 2 x RGB LED strip Light output 120 000 lm Strobe linear 1 15Hz Strobe blinder 25Hz Housing Metal flame retardant plastic Color Black DMX control via standard DMX controller Onboard LCD display for easy setup Circuit breaker 16A Control Manual Master Slave DMX 512 RDM IP rating IP 20 Connections 3 pin 5 pin XLR IN OUT Pro power connector Blue IN Cooling Cooling fan Max ambient temperature ta 35 ...

Page 22: ...21 Ordercode 40297 Titan Strobe BLAZE Dimensions ...

Page 23: ...22 Ordercode 40297 Titan Strobe BLAZE ...

Page 24: ... 2017 Showtec ...

Reviews: