background image

 

 

 

 

 

 

 

 

 

Static strength – 1,000 lbs. (454kg) 

 

Tested to 250,000 cycles (UL Tested) 

 

Low current draw: 300mA@12VDC & 
150mA@24VDC 

 

The SD-996C-NUVQ is intended to be used with 
UL Listed Exit Hardware 

 

The SD-996C-NUVQ shall not impair the intended 
operation of an emergency exit 

 

The SD-996C-NUVQ shall not impair the operation 
of panic hardware mounted on the door 

 

12/24 VDC Operation 

 

Vertical adjustable deadbolt opening, sliding  
shim keeper, and deadlatch ramp  
accommodates a wide range of lock types 

 

Accommodates deadbolts up to 1" 

 

Field selectable for fail-safe or fail-secure  

 

Includes 5 different stainless-steel faceplates 

 

Includes trim plate to hide gaps in installation 

 

Reversible non-handed design fits either  
right-hand or left-handed doors 

 

Indoor Use Only 

Features: 

SD-996C-NUVQ 

Electric Door Strike  

with Vertical Adjustment 

Manual 

43RG 

Summary of Contents for SD-996C-NUVQ

Page 1: ...ic hardware mounted on the door 12 24 VDC Operation Vertical adjustable deadbolt opening sliding shim keeper and deadlatch ramp accommodates a wide range of lock types Accommodates deadbolts up to 1 F...

Page 2: ...cycles UL Tested Level IV Destructive attack Level I Line security Level I Standby power Level I Latch throw 1 25mm max with 1 8 3mm door gap Dimensions 113 16 x15 8 x35 16 47x42x84 mm Note Not all p...

Page 3: ...distance X from the side of the door frame and distance Y from the top of the door frame Use a pencil to mark the exact spot where the two lines intersect 2 Carefully peel off the short thin tab in t...

Page 4: ...Tabs Mounting Tabs Using the stick on template as a guide 1 Drill holes for mounting the strike and cut a hole for the face plate size being used It is recommended to cut the hole slightly smaller th...

Page 5: ...11D2Q faceplates with the mounting tabs shown in Mounting the Strike Using Mounting Tabs page 4 SD 996SS 11L1Q Note If it is necessary to cut a hole in the frame mounting tabs may be required to stre...

Page 6: ...y Polarity of wires is not important Crimp connectors are provided to make wiring connections easier and more reliable To install the connectors 1 Insert the wires into the connector see 12 24 VDC Wir...

Page 7: ...d adjust the deadbolt keeper up and down to align with the marked lines Adjusting Deadbolt Keeper 1 Move the door close to the strike and mark the deadlatch limit lines on the strike keeper when they...

Page 8: ...and workmanship while used in normal service for three 3 years from the date of sale to the original customer SECO LARM s obligation is limited to the repair or replacement of any defective part if th...