Страница 1: ...Installation and Operations Manual Seaira Global LLC 14021 NC Highway 50 Surf City NC 28445 910 660 0962 WatchDog NXT85 ...

Страница 2: ...How it Works Installation Requirements Installation Key Functions Indicator Lights Remote Control Operating Instructions Unit Diagram Maintenance Dehumidifier Storage Ducted Applications Troubleshooting Spare Parts Warranty Information 2 2 3 3 3 4 4 6 7 8 9 9 11 11 12 13 14 ...

Страница 3: ...cted with at least 15 amp capacity The use of any other type of wiring will void your warranty Install dehumidifier according to all applicable local state and national codes Be sure to follow your GFCI manufacturer s maintenance instructions You will typically need to test the operation of the trip circuit monthly For ease of testing and operation it may be helpful to put the test switch and indi...

Страница 4: ...s an evaporator coil which is cooler than the dew point of air This means moisture will condense out of the air The air is then reheated through the condenser coil and distributed back into the room Installation Requirements The area where the dehumidifier is located should be sealed with a vapor barrier If the unit is installed in a crawl space all vents should be sealed For proper ventilation ne...

Страница 5: ...C into a 3 4 elbow 3 Attach PVC elbow to a 3 4 OD length of PVC to drain Keep the length of PVC as short as possible 4 Insert the open end of dehumidifier drain tube into 6 piece of PVC so that it does not extend into elbow fitting 5 For a proper flow a minimum downward slop of 1 per 10 run is required 6 Support the PVC tubing so that it maintains a smooth downward flow to drain 3 Plug unit into a...

Страница 6: ...osed on the external device Note that you may need to unplug the unit to reset the error code To set the unit to run continuously regardless of humidity simply use the down arrow key to set the humidity below 36 The continuous light will illuminate green and the display will show CO 3 Continuous Mode Use the up and down arrows to set the desired humidity setpoint on the display screen The setpoint...

Страница 7: ...cated If the humidity is above the setpoint the light will be solid green and the machine will operate If the humidity is below the setpoint the unit will be in standby mode and the light will be flashing 3 Continuous Mode Auto Defrost Light When the light illuminates green it indicates that the dehumidifier is set to continuous operation mode When the light illuminates red it means the unit is in...

Страница 8: ...ote is powered on 1 On Off Power Button Press the on off button and the machine will start running two beeps Press the button again to turn the machine off 2 Up Button Down Button Use the up and down arrows to adjust the humidity level 3 Mode Use the mode button to switch between dehumidifier and a ducted application The symbol on the display indicates the sensor on the remote control is being uti...

Страница 9: ...se the up and down arrow keys to adjust your desired setpoint typically 50 55 3 Stop the machine Press the power button again and the dehumidifier will stop Note that the fan will continue to operate for 1 minute after the unit has shut off DO NOT DISCONNECT THE POWER CORD TO FORCE THE UNIT TO STOP 4 Water Drainage ...

Страница 10: ...ore doing any maintenance Cleaning the Machine Body Use a soft damp cloth to clean the exterior of unit Do not use any soap or solvents Coil Maintenance Once per year clean the coils with an approved coil cleaner The coil cleaner should be a self rinsing foaming cleaner such as WEB Coil Cleaner Unit Diagram ...

Страница 11: ...n the control board cover Mix a 16 ounce solution of bleach 1 oz bleach 15 oz water OR vinegar 4 oz white vinegar 12 oz water Remove filter s so you have access to the drain tray Disconnect power to dehumidifier Pour the cleaning solution into the drain tray at the base of the coils If any cleaning solution gets on the coils flush with water Allow solution to soak for 15 minutes Pour in 16 32 ounc...

Страница 12: ...difier allows the unit to be in one room while conditioning an adjacent room Both the inlet return grille and the supply grille are designed for 10 flex ducting Ducting Installation Notes Be sure to secure the ducting with tie wrap Maximum total length of duct run 10 Inlet and outlet duct adapters are optional accessories Duct Adapter Installation Screw in the 4 screws on each duct adapter Flex Du...

Страница 13: ...12 Troubleshooting ...

Страница 14: ...13 Spare Parts ...

Страница 15: ... the day the shipment left the warehouse Please be sure to record serial and date of installation in the spaces provided on page 2 of the manual You will need this information to receive an RA number 2 If warranty service is necessary customer must contact Seaira Global Tech Support by phone 910 660 0962 to receive a Return Authorization RA number 3 Once an RA has been issued it is the customer s ...

Страница 16: ...ND LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED IN LAW OR IN FACT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE SEAIRA GLOBAL S TOTAL LIABILITY REGARDLESS OF NATURE OF CLAIM SHALL NOT EXCEED ORIGINAL PURCHASE PRICE OF THE PRODUCT IF A PRODUCT OR COMPONENT IS REPLACED WHILE UNDER WARRANTY THE APPLICABLE WARRANTY PERIOD SHALL NOT...