1.

 

Introduction 

The GSM-R5-DINW (

GSM rele

5

 for short)

 is designed to be mounted on a DIN rail 

into  a  switchboard.

  

GSM rele

5

 can  control two independent electrical  circuits in a 

building  e.g.  circuit  of  an  accumulator  stove  and  circuit  for  garage  gate  control. 

GSM rele

5

 uses 

GSM network and WiFi network

. If both connections are available, 

then  WiFi  is  preferred.  The  control  is  made  via  SMS  messages  or  by  ringing.  After 
installation into an electrical box insert a SIM card of any GSM operator and the device 
is ready to operate.

 

 

The 

GSM rele

5

 has 

2 digital outputs (Y5, Y6)

 with a relay, which can control directly 

power circuits up to 230 V

AC

/5 A. It’s possible to control directly e.g. a thermoregulator 

circuit of  a  gas boiler or  a  coil of one phase contactor 230V AC. The contact of  the 
contactor  can  then  control  either  one  phase  high  power  appliance  (e.g.  electrical 
radiator) or a coil of three phase contactor of an accumulation stove. 

 

The 

GSM rele

5

 has also 

2 digital inputs (X1, X2)

  and 

2 analog inputs (A3, A4).  

Digital inputs are determined for potencial free contacts. Analog inputs can be used for 
measuring the temperature, current or voltage. 

GSM rele

5

 has built in two 

automatic 

regulators

  which  use  analog  inputs  from  temperature  sensors  to  maintain  preset 

temperature. The temperature of sensors can be readout via SMS. 

 

There is an internal 

built in Li-POL accumulator

 which allows to send an SMS in case 

of a power failure and to restore the output status after a power failure. It’s also possible 
to monitor the status of inputs and temperatures via SMS during 230 V

AC

 power failure.  

 
Internal 

data  logger

  keeps  records 

about events and valued of inputs. 

 

 - device state indication 

 - OUTPUT Y5, Y6 connectors 

 - 230V

AC

 Power supply connector 

 - Push buttons - local control Y5, Y6 

 - OUTPUT Y5, Y6 state indication 

 - INPUT X1, X2 connectors 

 - ANALOG INPUT A3, A4 connectors 

 - GSM antenna connector 

 - USB connector (for configuration) 

 - nano SIM card holder 

 - WiFi antenna connector 

 

2.

 

Package 

Content 

 

1 pc 

GSM rele

5

 (order code 

GSM-R5-DINW

 

1 pc GSM antenna ANT05S (order code GSM-ANT05S) 

 

1 pc WiFi antenna W-ANTKLB

 

 

 

1 pc temperature sensor GSM-C-T2 (based on KTY81-
210), cable - 1 meter 

3.

 

Installation 

1.

 

To operate the 

GSM rele

5

 a SIM card of any GSM operator is necessary. SIM 

card must be functional and active. Also some credit is necessary if SIM card is pre-
paid. We recommend to deactivate the PIN code for installation.  

2.

 

The SIM card holder can accommodate 

nano SIM card 

only (12,3 x 8,8 

mm).  

3.

 

Insert this prepared SIM card (cut off 

corner  first)  into  a  SIM  card  holder.  The 
proper  insertion  is  indicated  by  a  slight 
mechanical  click  noise.  To  remove  the  SIM 
card - press the SIM card in direction into the 

GSM

 rele

5

  until  mechanical  click.  The  SIM 

card can be the freely removed.  

4.

 

Now  it’s  possible  to  connect  the  device  to  230V  AC  power  supply.  If  the 

power supply is correct, green LED 

PWR

 goes on and blue LED 

GSM

 is flashing 

slowly. After about 20 seconds, blue LED diode GSM starts flashing with a period 1 
per 3 sec.  (registered). 

5.

 

For the first tests of 

GSM rele

5

 the connection of inputs and outputs is not 

important.  Please  keep  in  mind  that  the  devices  connected  to  OUTPUTS  will  be 
switched on during tests!  

6.

 

To test the 

GSM rele

5

 press the push button bellow Y5 for a local control. 

The yellow LED diode for Y5 lights ON and relay for output Y5 switch on. Send an 
SMS from mobile phone (which will be mainly used to control the 

GSM rele

5

) in form 

1234 OFF

 to the telephone number of the SIM card inserted into the 

GSM rele

5

This  will  switch  off  output  Y5  and  the  yellow  status  LED  for  Y5  goes  OFF. 
Simultaneously,  the  device  automatically  sends  a  confirmation  SMS  message  on 
performing  the  operation.  The  password  1234  can  be  changed  later  in 
configuration. The 

GSM rele

5

 reacts on the SMS text message from any telephone 

as long as the access password matches. The very first one (the sender of the first 
valid SMS message) will be remembered as master and will receive messages about 
events  on 

GSM rele

5

.  This  user  can  also  control  the  device  by  “ringing”  on  the 

device. 

7.

 

Try “ringing” on device. You can make pulse on Y6 for approx. 4 seconds by 

calling to 

GSM rele

5

 (with default factory setting). The device hangs up the call and 

makes pulse on the Y6. This pulse can be used for example for opening entrance 
gate. To test this function call from the phone (which was used to send the first 
test SMS to switch off the Y6). The pulse is indicated by yellow LED below Y6 push 
button. 

8.

 

Try  regulation.  By  default  the  regulation  of  Y5  depends  on  temperature 

sensor  connected  to  analog  input  A3.  So  connect  a  temperature  sensor  into  a 
analog input A3. Send SMS in form of 

1234 Y5 REG 25

 to command the device to 

maintain temperature to 25°C. The range of regulation is between 0°C and +55°C. 
Regulation can be canceled by SMS with command 

1234 Y5 OFF

.  

9.

 

A default factory setting of the 

GSM rele

5

 can be recovered by an SMS in 

form 

1234 !FACTORY. 

If you made a backup configuration in  

SeaConfigurator

 

, your setting can be then restored from backup configuration of 

SeaConfigurator

 

program.  

10.

 

Names of input, outputs (and its states) and names of commands is possible 

to change in 

SeaConfigurator

 program.  Visit 

www.seapraha.cz

 for download it 

for free and install the program to your PC. 

4.

 

Technical Specifications 

Parameter 

Symbol 

Cond. 

MIN. 

TYP. 

MAX. 

Units 

Dimensions 

Width 

W

 

 

 

52 

 

mm 

Height 

 

 

90 

 

mm 

Depth 

 

 

66 

 

mm 

Power  

supply 

*1)

 

Voltage 

 

180 

230 

250 

V

 

AC 

Consumption 

 

 

 

Backup 
power supply 

 

 

integrated 

 

 

day 

Digital inputs 

X1, X2 – potencial free contact 

 

Digital 

outputs 

Y5, Y6 – relay 

Voltage 

V

OUT

 

 

 

 

250 

30 

V

 

AC 

V

 

DC 

Current 

I

OUT

 

 

 

 

Power 

 

 

 

 

1250 

150 

VA 

Analog inputs 

A3, A4  - set by user as: 

Voltage 0-10V; 

Current 0-20mA (input resistance 75

); 

temperature for sensors: 

KTY (-50 to +150°C);  

Pt100 (-100 to +300°C);  

Pt1000 (-100 to +300°C) 

Resolution 

 

 

12 

 

 

bit 

GSM module 

Frequencies 

 

 

850/900/1800/1900 

MHz 

WiFi module 

Frequency 

 

 

2,4 

GHz 

Bluetooth 

Frequency 

 

 

2,4 

GHz 

Humidity 

 

 

 

 

 

90 

Temperature 

Storage 

without supply 

 

 

 

 

*2)

 

months 

Operational 

tA 

 

-20 

 

+45 

°C 

Use 

GSM rele

5

 - DIN inside the rack with IP44 or better!

!

 

*1)

 Use breaker max. 10 A before 

GSM rele

5

. For power supply 230V

AC

 use lines min. 

1 mm

2

.

 

*2)

 The 

GSM rele

has to be connected to 230V

AC

 power supply every 3 months for 

24 hours (due to internal accumulator).

 

5.

 

Hardware 

5.1

 

Connectors 

2 digital inputs, 2 analog inputs  and 2 digital 
outputs can be connected

 

GSM rele

5

.  

 
L, N – main power supply 230 V

 

AC 

Y5, Y6 – digital outputs 
A3, A4 – analog inputs 
X1, X2 – digital inputs 
 
Analog  inputs  can  be  used  for  temperature 
measurement  using  KTY81-210,  PT100  or 
PT1000 sensor. Length of wires to the sensor 
is  not  limited,  but  be  aware  of  resistivity  of 
these wires. For KTY81-210 16 Ω means 1°C. 
 
ATTENTION: Do not exceed the parameters of 
inputs  and  outputs  –  Chapter 

Tech. 

Specification

.  

For  examples  of  connection  see  the  chapter 

Examples of connection

.  

1.

 

Before inserting the SIM card into the 

GSM

 rele

5

 device, we 

recommend to turn off setting of the “PIN code”! 

2.

 

Insert the active SIM card (= at least one call was made) to any mobile 
telephone  and  turn  off  the  requirement  of  setting  the  PIN.  On  most 
mobile  telephones,  this  option  can  be  found  in  menu  “Setting  the 
telephone protection”. or “Setup -> Security -> PIN control”. 

ATTENTION:   

3.

 

GSM

 rele5

 must be mounted by qualified personnel only! 

 

Summary of Contents for GSM-R5-DINW

Page 1: ...to the GSM rele5 This will switch off output Y5 and the yellow status LED for Y5 goes OFF Simultaneously the device automatically sends a confirmation SMS message on performing the operation The passw...

Page 2: ...mmands LED COLOR Meaning Off On Blink 1 per 3s 1 1 PWR green device is off powered from 230 V AC powered from backup battery ERR red no error error GSM blue No GSM signal registered Searching GSM net...

Page 3: ...lation of OUTPUT Y6 will be set to 5 C Using multiple commands in one SMS message can look like this 1234 Y5 OFF Y6 REG 25 switch off output Y5 and sets temperature regulation on output Y6 to 25 C acc...

Page 4: ...d by the best software engineers in SEA and was carefully tested both in SEA and also by SEA customers using GSM applications products made in SEA In spite of making all possible to get error free sof...

Page 5: ...4 Y5 ON heat up to 22 C a 1234 Y5 OFF turn off heater If temperature drops below 5 C Output Y5 will be switched on and regulates to nonfreezing temperature If you have enabled heating to freezing temp...

Page 6: ...n to 25 C 1234 Y6 OFF Y5 TEPL 25 thermoregulator is disabled Regulation to 22 C 1234 Y6 ON Y5 OFF thermoregulator is set to 22 C Regulation to 7 C 1234 TEPL 7 thermoregulator is disabled 10 3 Digital...

Page 7: ...ile operator for help if necessary Check credit on a pre paid SIM card Ask your mobile operator for help if necessary Test the SIM card in your mobile phone The mobile phone should show the signal lev...