background image

User and Installation
Manual for
Modular Flaked & Nugget Ice Machines

Models F0822, F1222, F1522,
N0622, N0922 and N1322

Remote Low Side

Summary of Contents for F0822

Page 1: ...User and Installation Manual for Modular Flaked Nugget Ice Machines Models F0822 F1222 F1522 N0622 N0922 and N1322 Remote Low Side ...

Page 2: ...ol and the ability to add options This user and installation manual is organized in three main sections installation operation and maintenance July 2009 Page 1 N0622L F0822L N0922L F1222L N1322L F1522L Remote Low Side User s Manual Table of Contents Installation Page 2 Location Page 3 Cabinet Layout Page 4 Unpacking Page 5 Water Page 6 Electrical Page 7 Refrigeration Page 8 Final Check List Page 9...

Page 3: ...lids Check with a water treatment service for a recommendation RO water This machine can be supplied with Reverse Osmosis water but the water conductivity must be no less than 10 microSiemens cm Potential for Airborne Contamination Installing an ice machine near a source of yeast or similar material can result in the need for more frequent sanitation cleanings due to the tendency of these material...

Page 4: ...its side by side BH1100 BH1300 and BH1600 upright bins include filler panels to accommodate a 22 inch wide ice machine No adapter is needed Dispenser compatibility Only nugget ice models may be used with ice dispensers Flaked ice is not dispensable ID150 use KBT42 and KDIL PN 150 includes KVS KNUGDIV and R629088514 ID200 use KBT43 and KNUGDIV and KVS ID250 use KBT43 and KNUGDIV and KVS See sales l...

Page 5: ...OPENING PLANVIEW ULTRASONIC BINLEVEL SENSOR OPTIONAL 24 00 61 LEFTSIDEVIEW 13 35 33 9 1 59 4 2 63 6 7 14 36 36 5 16 86 42 8 18 81 47 8 21 81 55 4 BACKVIEW 5 8 O D REMOTE SUCTION CONNECTION 3 8 O D REMOTE LIQUIDLINE CONNECTION 3 4 FPTDRAIN 3 8 FLARE MACHINE WATERINLET 120VOLTCORD 22 00 55 9 27 00 68 6 22 89 58 1 FRONTVIEW Note Bin Top Cut outs for drop zone should include ultrasonic sensor location...

Page 6: ...hanging the bezel in the front panel s trim strip A cover up bezel is included with the hardware bag Remove any packaging such as tape or foam blocks that may be near the gear reducer or ice chute Level the bin and ice machine front to back and left to right by using the bin leg levelers Panel Removal 1 Locate and loosen the two screws at the front edge of the top panel 2 Pull the front panel out ...

Page 7: ...ing at the back of the cabinet Tubing Connect the potable water supply to the potable water fitting 3 8 OD copper tubing or the equivalent is recommended Connect the drain tube to the condensate drain fitting Vent this drain tube Do not Tee ice machine drains into the drain tube from the ice storage bin or dispenser Back ups could contaminate and or melt the ice in the bin or dispenser Follow all ...

Page 8: ... a separate power supply Do not use an extension cord Follow all local and national codes July 2009 Page 7 N0622L F0822L N0922L F1222L N1322L F1522L Remote Low Side User s Manual Model Dimensions w x d x h Voltage Volts Hz Phase Min Circ Ampacity Max Fuse Size N0622L 1 22 x 24 x 27 115 60 1 5 8 15 N0922L 1 same 115 60 1 5 8 15 N1322L 1 same 115 60 1 5 8 15 F0822L 1 same 115 60 1 5 8 15 F1222L 1 sa...

Page 9: ... the roof of the building using the methods and practices of construction that conform to the local building codes including having a roofing contractor secure the condenser to the roof Refrigeration Installation Connections The liquid and suction fittings on the back of the cabinet are stubs The liquid line size is 3 8 OD The suction line size is 5 8 OD 1 Recover holding charge 2 Cut the stubs of...

Page 10: ...en properly connected to the condensing unit or rack Control Operation Use and Operation Once started the ice machine will automatically make ice until the bin or dispenser is full of ice When ice level drops the ice machine will resume making ice Caution Do not place anything on top of the ice machine including the ice scoop Debris and moisture from objects on top of the machine can work their wa...

Page 11: ...egularly All models need scale removed from the water system All models require regular sanitization All models require sensor cleaning All models require a top bearing check Maintenance Frequency Scale removal At least twice a year in some water conditions it might be every 3 months The yellow De Scale Sanitize light will switch on after a set period of time as a reminder The default time period ...

Page 12: ...orator by disconnecting the leg of the hose connected to the water sensor and draining it into the bin or a bucket Return the hose to its original position Discard or melt all ice made during the previous step 13 To sanitize the water system mix a locally approved sanitizing solution An example of a sanitizing solution is mixing one ounce of liquid household bleach and two gallons of 95 115 degree...

Page 13: ... grease is white over time some gray will appear over the rollers that is normal Add grease to replace gray grease or if gaps between rollers are visible If grease is watery all gray or rust is visible have the bearing replaced See the next page for more information Note When checking the top bearing always inspect the drip pan for water seal leaks If water is present in the drip pan service the w...

Page 14: ...needed If very gray rusty wet or has any embedded metal have the bearing replaced July 2009 Page 13 N0622L F0822L N0922L F1222L N1322L F1522L Remote Low Side User s Manual Needle pn 02 3559 01 Bearing Check Drip Pan For Water Drip Pan Change De Scale Notification Interval This feature is accessible only from standby Status Light Off 1 Press and hold Clean button for 3 seconds Starts the Time to Cl...

Page 15: ...he arrow on the label Dispenser applications Nugget ice only Set the adjustment knob to either the first or second position CW after the maximum fill position Smart Board Optional Advanced Feature Board KSBU When this option is present there is an additional display panel in the area below the main control board It is not visible when the front panel is on The Advanced Feature Board s features inc...

Page 16: ...eck auger motor for power if no power check controller component indicator light If there is power to the motor check motor windings Code 2 Auger motor draws too many amps controller shuts unit off Check that liquid line valve shuts off tightly Check for damage to gear reducer or auger bearings Bin Eyes Blocked light is On Ice is in the chute No ice in the chute Check position of sensors check sen...

Page 17: ...flow to it 2 Has power been shut off to the ice machine If yes the ice machine will automatically restart when power is restored 3 Has someone shut the power off to the remote condensing unit while the ice machine still had power If yes the ice machine may need to be manually reset To Manually Reset the machine Push and release the Off button Push and release the On button To Shut the Machine Off ...

Page 18: ...SCOTSMAN ICE SYSTEMS 775 Corporate Woods Parkway Vernon Hills IL 60061 800 533 6006 www scotsman ice com 17 3226 01 ...

Reviews: