manualshive.com logo in svg
background image

q

 SEL

ECT

 Power Supply With I/O (Slot A)

w

 SEL

ECT

 Processor and Communications Card (Slot B)

e

 SEL

ECT

 I/O Expansion Card (Slot C: see table)

r

 SEL

ECT

 I/O Expansion Card (Slot D: see table)

t

 SEL

ECT

 I/O Expansion Card (Slot E: see table).

y

 SEL

ECT

  4 ACI/3 AVI  or  4 ACI Card  (Slot Z)

u

 Device Case

i

 Rear-Panel Mounting Screws 

o

 Rear Panel

Refer to the Model Option Table on the SEL website for ordering details

Rear-Panel Slot

Card Type 

A

B

C

D

E

Z

SEL

ECT

 PSIO/2 DI/3 DO

a

a

Refer to the SEL-751 two-line and touchscreen display Model Option Tables (MOT) for power supply and CPU board variants.

 n/a

n/a

n/a

n/a

n/a

SEL

ECT

 CPU/COM

a

n/a

 

n/a

n/a

n/a

n/a

SEL

ECT

 EIA-232/EIA-485

n/a

n/a

 n/a

n/a

n/a

SEL

ECT

 DeviceNet

n/a

n/a

 

n/a

n/a

n/a

SEL

ECT

 3 DI/4 DO/1 AO (one card per relay)

n/a

n/a

 

 

 n/a

SEL

ECT

 4 DI/4 DO

n/a

n/a

 

 

 

n/a

SEL

ECT

 4 DI/3 DO (1 Form B, 2 Form C)

n/a

n/a

 

 

 n/a

SEL

ECT

 8 DI

n/a

n/a

 

 

 

n/a

SEL

ECT

 14 DI

n/a

n/a

 

 

 n/a

SEL

ECT

 8 DO

n/a

n/a

 

 

 

n/a

SEL

ECT

 8 AI

n/a

n/a

● ● ●

 n/a

SEL

ECT

 4 AI/4 AO (one card per relay)

n/a

n/a

● 

● 

 

n/a

SEL

ECT

 10 RTD

n/a

n/a

n/a

● 

n/a

n/a

SEL

ECT

 2 AVI/4 AFDI (MOT…x70x…)

n/a

n/a

n/a

n/a

 

n/a

SEL

ECT

 2 AVI/4 AFDI (MOT…xL0x…)

n/a

n/a

n/a

n/a

 n/a

SEL

ECT

 8 AFDI (MOT…x77x…)

n/a

n/a

n/a

n/a

n/a 

SEL

ECT

 4 ACI/3 AVI (MOT…x81/82/83/85/86/87x…)

n/a

n/a

n/a

n/a

n/a

 

SEL

ECT

 4 ACI/3 AVI (MOT…xL1/L2/L3/L5/L6/L7x…)

n/a

n/a

n/a

n/a

n/a

 

SEL

ECT

 4 ACI (MOT…xA1/A2/A3/A5/A6/A7x…)

n/a

n/a

n/a

n/a

n/a

 

6

7

8

9

1

2

3

4

5

SEL-751 Card Options

Содержание SEL-751

Страница 1: ... n a SELECT CPU COMa n a n a n a n a n a SELECT EIA 232 EIA 485 n a n a n a n a n a SELECT DeviceNet n a n a n a n a n a SELECT 3 DI 4 DO 1 AO one card per relay n a n a n a SELECT 4 DI 4 DO n a n a n a SELECT 4 DI 3 DO 1 Form B 2 Form C n a n a n a SELECT 8 DI n a n a n a SELECT 14 DI n a n a n a SELECT 8 DO n a n a n a SELECT 8 AI n a n a n a SELECT 4 AI 4 AO one card per relay n a n a n a SELEC...

Страница 2: ...interference protection make sure the contact fingers on the printed circuit board are bent at approximately a 130 angle relative to the board 7 Before reattaching the rear cover check for and remove any foreign material that may remain inside the SEL 751 case 8 Carefully reattach the rear cover 9 Reinstall the eight 8 screws that secure the rear cover to the case i 10 Apply power supply voltage q...

Страница 3: ... remain unchanged i e these digits retain the same character as before the reconfiguration A communications card DeviceNet or EIA 232 EIA 485 installed in Slot C will be reflected as an empty slot in the part number A regular 4 DI 4 DO card and a hybrid 4 DI 4 DO card have the same device ID When interchanging these two cards the part number for the respective slots should be updated manually Use ...

Страница 4: ...the instruction manual Perform the following steps to replace the existing CPU board with a new board 1 Turn off the power to the relay 2 Use a ground strap between yourself and relay 3 Disconnect the terminal blocks and CT PT wires 4 Remove the rear panel 5 Remove the main board from its slot and insert the new board 6 Install the new rear panel and reconnect the terminal blocks and CT PT wires 7...

Отзывы: