Page 1: ...www schweigen com au RANGEHOOD INSTALLATION GUIDE CL8815S Revision V1 12 03 20...

Page 2: ...5 Cleaning Maintenance 9 Surfaces 9 Filters 9 Cleaning the Interior 10 Cleaning the Exterior 10 Replacing the Light Bulb 11 6 Installation 12 Rangehood Size vs Cooktop Size 12 BBQ Installation 12 Moun...

Page 3: ...website www schweigen com au This appliance and its packaging are produced by processes that minimise waste and respect the environment Please help us to continue this effort to protect the environmen...

Page 4: ...no flames emerge from the sides of pans 8 Do not leave packaging materials bags corner brackets etc within reach of children 9 This appliance is not intended for use by person s including children wi...

Page 5: ...pply with a ground connection 10 Check that the installation and electrical connections are made by a qualified technician and that the indicated instructions and local regulations in force are met us...

Page 6: ...ons After use always ensure that all controls are in the OFF position When frying with a gas flame take particular care not to allow the oil or grease in the pan to catch fire Flamb Electrical Cord En...

Page 7: ...n Rangehood 1 Mounting Bracket 2 Upper Flue 3 Lower Flue 4 Power Cord 5 2x 200mm outlets 6 Rangehood Body 7 Lights 8 Baffles 9 Remote Control NOTE Filter and light quantity may vary from model to mode...

Page 8: ...mum speed 4 Turns the lights on or off 5 10 minute timer NOTE If there is no change in operation to the unit in 4 hours it will shut down all functions including lights and extraction fans available o...

Page 9: ...y important for the liquid soap to not contain granules that could scratch the surface First apply the solution to a soft cloth and then rub the cloth over the rangehood It is important to follow the...

Page 10: ...days depending on use The bafles can be washed by hand or in the dishwasher Washing by hand Immerse the filter in hot water and a suitable detergent and when clean rinse with plenty of hot water Dishw...

Page 11: ...for a short period of time after being switched off Replacing the Light Bulb Step 2 Gently turn light bulb clockwise pull the light bulb down and remove it from the light holder Step 3 Insert a new l...

Page 12: ...ame size as cooking zone OPTIMAL Rangehood larger than cooking zone BBQ Installation When installing the rangehood over a BBQ please be aware that the lid will obstruct the rangehoods effectiveness to...

Page 13: ...rements are from the top of the trivets to the lowest part of the rangehood including the button controls IMPORTANT If the user decides to install the rangehood at a distance of less than minimum heig...

Page 14: ...re to do so may damage the clips Wall Mount Installation There are two primary mounting points and several secondary mounting points to firmly fix the rangehood in place Suitable fixing screws must be...

Page 15: ...removed and put in a safe place while installing rangehood to prevent damage Step 1 Secure rangehood to the wall using only primary mounting points 1 Check the level of the rangehood and adjust accord...

Page 16: ...gth required Be careful not to scratch the top of the rangehood PLEASE NOTE Only a standard length of stainless steel flue is provided Any additional length will need to be sourced and manufactured by...

Page 17: ...s The supplied ducting has been manufactured with an allowance for the back draft fins to operate without hindrance It is the smooth extended end of the ducting When installing Back Draft Fins please...

Page 18: ...Page 18 6 Installation Isodrive Motor Setup Note Please refer to the Isodrive motor installation guide for more details on flexi ducting and Isodrive motor installation...

Page 19: ...200 x 200mm 8 Mains power 9 Flexi Ducting must be pulled taut DO NOT crush or kink the ducting 10 Connect flexi ducting to the outlet on rangehood using ring clamp Please DO NOT rip the ducting 1 2 3...

Page 20: ...led taut DO NOT crush or kink the ducting 9 Connect flexi ducting to the outlet on rangehood using ring clamp Please DO NOT rip the ducting 1 2 3 4 5 6 7 8 9 DANGER All electrical wiring from the moto...

Page 21: ...ruction of a bulkhead is also recommended The position of the motor can be to an external wall as shown above or to the same external wall as the rangehood is mounted as shown below For all wall insta...

Page 22: ...should be firmly in position Check light bulbs Make sure they are not broken or faulty Please make sure there is no obstruction in ducting or with the back draft fins Check the outlet make sure it is...

Page 23: ...e appliance at their expense Service Lodging an Online Service Request In the event that the failure is not due to the faults mentioned in the Troubleshooting section you can lodge an online Service R...

Page 24: ...Page 24 8 Specifications Technical Specifications Model CL8815S Feeding Voltage 220 240V 50Hz Lamp Power LED W 3 x 3 5W Dimensions 435 335 338 4 0 0 320 750 1500 100 1 2 2 0 4 0 0 438...

Page 25: ...with the Isodrive Motor or online at schweigen com au Schweigen Home Appliances has presented this information in good faith to all their retailers and distributors to convey before any all purchase s...

Page 26: ...Page 26 Notes...

Page 27: ...Page 27 Notes...

Page 28: ...Court Mulgrave 3170 Victoria Phone 1300 881 693 Email sales schweigen com au Web www schweigen com au New Zealand 5 Tolich Place Henderson Auckland 0610 Phone 0800 200 510 Email info parex emerson co...