background image

Summary of Contents for Touchless ADO

Page 1: ......

Page 2: ...o is not certified as an AAADM inspector Following the installation or service of any S G automated pedestrian door product if it is deemed unsafe or is operating in an unsatisfactory manner according...

Page 3: ...oduct Description Specifications 5 14 STEP 1 Housing Backplate Installation 15 16 STEP 2 Re mounting Operator Motor Drive Assembly 17 25 STEP 3 Install The Arm Assembly Standard Applications 26 27 STE...

Page 4: ...t Driven Encoder Header Dimensions 4 1 2 x 4 7 8 l x w x d length 39 45 51 for 36 42 48 opening respectively Fused Protection 3 5A Fuse F1 located on I O Board Motor Assembly Weight 22 lbs Per Operato...

Page 5: ...by removing the 4 hex screws on the top bottom of the operator The motor assembly should be removed before installing the housing back plate NOTE When you order a PULL or PUSH operator the motor asse...

Page 6: ...nfiguration The keyhole allows for easy removal of the drive plate without the need to loosen the 5th bolt Removing the four 4 bolts allows the drive plate operator to be removed from the header and i...

Page 7: ...n Required One Security Dr Nicholasville Kentucky 40356 S G TOUCHLESS ADO docx REV 08 2021 7 Remove the drive plate by shifting the drive plate to the left and lifting the drive plate away from the ba...

Page 8: ...h side mounting Pre drilled back plate is flush with bottom of door frame Standard Pull side mounting Pre drilled back plate is mounted 1 5 up from bottom door frame For non standard mounting longer s...

Page 9: ...TANDGREENLEAF COM t 800 826 7652 859 885 9411 E mail Information Required One Security Dr Nicholasville Kentucky 40356 S G TOUCHLESS ADO docx REV 08 2021 9 1 Backplate should overlap hinge side jamb t...

Page 10: ...26 7652 859 885 9411 E mail Information Required One Security Dr Nicholasville Kentucky 40356 S G TOUCHLESS ADO docx REV 08 2021 10 DOOR PREP DRAWINGS PUSH SIDE INSTALLATION SINGLE DOOR Opening Width...

Page 11: ...tucky 40356 S G TOUCHLESS ADO docx REV 08 2021 11 PUSH SIDE INSTALLATION PAIR OF DOORS NOTES Hollow metal frame with 5 8 stop height shown A dimension is only located on the 72 96 operator C dimension...

Page 12: ...M t 800 826 7652 859 885 9411 E mail Information Required One Security Dr Nicholasville Kentucky 40356 S G TOUCHLESS ADO docx REV 08 2021 12 PULL SIDE INSTALLATION SINGLE DOOR Opening Width Housing Wi...

Page 13: ...2 859 885 9411 E mail Information Required One Security Dr Nicholasville Kentucky 40356 S G TOUCHLESS ADO docx REV 08 2021 13 PULL SIDE INSTALLATION PAIR OF DOORS Opening Width Housing Width A Dim C D...

Page 14: ...One Security Dr Nicholasville Kentucky 40356 S G TOUCHLESS ADO docx REV 08 2021 14 DOUBLE EGRESS INSTALLATION PAIR OF DOORS Shown with Double Egress Arm on the right Push Arm with 80mm spindle on the...

Page 15: ...LESS ADO docx REV 08 2021 15 Auto Operator Auto Operator LHR RHR D o o r D o o r Hinge PUSH APPLICATION I O board towards the hinge Auto Operator Auto Operator Hinge LH RH D o o r D o o r PULL APPLICA...

Page 16: ...embly left or right to line up the 5th hex bolt nut with the mounting hole from the bolt removed on page 5 near the transformer Reinsert the hex bolt and washers removed on page 5 Temporarily remove o...

Page 17: ...STEP 3 INSTALL THE ARM ASSEMBLY STANDARD APPLICATION NOTE All operator arms include a standard spindle as shown below Arm assembly options are detailed on the next three pages Proceed to Page xx for a...

Page 18: ...N A SPACER PROVIDED BY INSTALLER MAY BE INSTALLED BEHIND THE SLIDE TRACK TO ACHIEVE A 0 REVEAL FOR A PULL APPLICATION WITH A REVEAL GREATER THAN USE A DOUBLE EGRESS ARM WITH A 20mm SPINDLE P N SP80 so...

Page 19: ...00 826 7652 859 885 9411 E mail Information Required One Security Dr Nicholasville Kentucky 40356 S G TOUCHLESS ADO docx REV 08 2021 19 80mm P N SP80 sold separately included with pull arm 50mm P N SP...

Page 20: ...S PAIR OF DOORS OR FOR A PULL APPLICATION WITH A REVEALGREATER THAN ZERO INCHES NOTE AN 80mm SPINDLE IS INCLUDED WITH THE DOUBLE EGRESS ARM THE 80mm SPINDLE SHOULD BE USED FOR DOUBLE EGRESS PAIR OF DO...

Page 21: ...13 X 16 X Pivot HINGE HUNG CENTER PIVOTED Follow the instructions listed below for a standard arm application using a push or a pull application PUSH ARM INSTALLATION Ensure the main power supply is...

Page 22: ...n If the reveal falls between two of the values on the chart use Reveal 13 for hinge hung doors or Reveal 16 for Center Pivot doors o Tighten the screws on the short arm that is connected to the door...

Page 23: ...erator DOOR 13 X 16 X Pivot HINGE HUNG CENTER PIVOTED PUSH ARM Install the door shoe per the door hinge pivot configuration o o o Hinge Hung Doors Centerline of door shoe at 13 5 in from inside of hin...

Page 24: ...e adaptor onto the primary arm until the two mounting holes of spindle line up with the corresponding holes on the primary arm The spindle is intended to fit tightly Secure the spindle using the two s...

Page 25: ...at approximately 90 degrees to the face of the door as shown it is not imperative that the arm be at this exact position Upon final installation of door arm assembly press SW1 to launch a new setup t...

Page 26: ...spindle using the two small hex bolts BUT DO NOT OVERTIGHTEN To install the pull arm the operator must be powered to the full open position as it is not possible to install the arm in the closed posit...

Page 27: ...THE STOPS IMPORTANT Step 4 may be optional depending on your application See note on the following page The mechanical stops are located on the top or bottom of the operator depending on the handing o...

Page 28: ...means of a temporary stop method such has holding your foot at the desired location during programming To use the Soft Stop method perform the following during the setup on Page 31 o During the first...

Page 29: ...supply 120 VAC 15A Single Phase 60 Hz circuit o Attach the incoming 120 volt AC line wires to the wiring provided in the header as shown below NOTE IF THE UNIT HAS TWO WHITE WIRES BOTH WILL CONNECT T...

Page 30: ...Switch is in the middle 0 position Apply power and observe the LED s on both boards o On the I O board LED s for inputs 12 13 14 must be ON upon power up o For the Adjustment board LED s see Page 26...

Page 31: ...accessories power LD2 Active internal opening command Internal opening command inactive Indicates status of input 10 LD3 Active external opening command External opening command inactive Indicates sta...

Page 32: ...o If the door does not open and the red LED LD2 is flashing slowly check to make sure the motor is plugged in properly at the control board Correct as necessary o Once the setup process is complete t...

Page 33: ...he dip switches according to the application The default settings are usually sufficient for most applications Dip switches are used to apply specific functions to the control There are 2 sets of dip...

Page 34: ...2021 34 STEP 7 Cont SET THE DIP SWITCHES ON THE ADJUSTMENT BOARD Set the dip switches according to the application See the table on the next page ON is with the switch towards the number Initial setup...

Page 35: ...liance if using on low energy application Cannot exceed 30 lbf to get door moving from jamb Disabled Default 2 Push Pull Arm Use for Slide Arm Applications Operator stroke at 90 degrees or less Visibl...

Page 36: ...lications Required when using Stall Safety input 14 7 Inhibit at 30 Degrees Before Door Fully Open Only used if Input 14 is used Input 14 is disabled at 30 degrees prior to full open door position Sta...

Page 37: ...at lockout relay when power is looped through thus switching power on when door is open TERMINAL STRIP J4 7 GND Common GND 8 GND Common GND 9 24 VDC 1A Max Current 10 Internal Activation Requires N O...

Page 38: ...4 Closing speed adjustment when power is OFF TR4 will only be enabled when jumper J6 is moved to the correct pins It is enabled by default J2 USB port J4 Ribbon cable connector between boards J5 Motor...

Page 39: ...osition Check the mechanical stops on the operator for proper adjustment see page 16 Slow flashing red LED LD2 at the Adjustment Control Board Indicates a possible fault in the control o Check LED sta...

Page 40: ...r may not open to its full open position it may stop short and then close as it thinks there was an obstruction Operator may make a loud clicking noise this is created by the chain jumping on the spro...

Page 41: ...ucky 40356 S G TOUCHLESS ADO docx REV 08 2021 41 Shown w door fully closed APPENDIX WIRING DIAGRAMS DOOR STATUS SWITCH OUTPUT Terminal 4 Door Closed status switch Contact closes upon full door closed...

Page 42: ...ally closed circuit Remove factory jumper on terminal 13 Door mounted sensor will cause re activation when in detection during the closing cycle Secondary activation input is disabled at the full clos...

Page 43: ...asville Kentucky 40356 S G TOUCHLESS ADO docx REV 08 2021 43 LOW ENERGY APPLICATION 2 WIRELESS PUSH PLATE WITH 24VDC ELECTRIC STRIKE OR MAGLOCK SDC Wireless Receiver Mounted in housing N O COM EMLock...

Page 44: ...INTERFACE IS USED VOLTAGE SELECTION SWITCHES SET FOR 24VDC TO 120VAC PRIMARY VOLTAGE CONNECTION Battery Input Terminals DC Voltage Output Terminals 24 12 C LR100 Series Latch Retraction Kit Red Blk 60...

Page 45: ...WW SARGENTANDGREENLEAF COM t 800 826 7652 859 885 9411 E mail Information Required One Security Dr Nicholasville Kentucky 40356 S G TOUCHLESS ADO docx REV 08 2021 45 LOW ENERGY APPLICATION 4 SIMULTANE...

Page 46: ...rs of controls N C inputs 12 13 and 14 may be sync d to each other OR each control may have its own jumpers installed If any of these inputs are required for the application the jumper will be removed...

Page 47: ...ding to the instructions outlined in this manual Additionally ensure the following conditions have been met o When attaching the door arm to the door use steel binding posts Sex Bolts to attach Do NOT...

Page 48: ...Always check to ensure compliance to local building codes o Upon job completion always perform a functional test to ensure that the door s close and latch following a power loss Other hardware may be...

Reviews: