background image

 

 

 
 

Uninterruptible Power Supply 

E11A

(TYPE C)

 Series 

A11F102/152 Series

 

Contact Signal Interface Card 

Terminal type

 

User Manual 

 

 
 

 

Table of Contents

 

 

Introduction 
Safety Precautions 

1. Confirming Package Contents --------------------  1 
2. Contact Signal Interface Card Part Names  ----   1 
3. Contact Signal Interface Card Installation  ------   2 
4. UPS Settings ------------------------------------------  5 
5. External Signals (“CONTACTS SIGNAL”)  --------8 
6. Special Functions ---------------------------------------9 

 

 

 
 
 
 

SANYO DENKI CO., LTD.

 

 

DWG.No. M0009173C

Summary of Contents for A11F102 Series

Page 1: ...al type User Manual Table of Contents Introduction Safety Precautions 1 Confirming Package Contents 1 2 Contact Signal Interface Card Part Names 1 3 Contact Signal Interface Card Installation 2 4 UPS Settings 5 5 External Signals CONTACTS SIGNAL 8 6 Special Functions 9 SANYO DENKI CO LTD DWG No M0009173C ...

Page 2: ...d Storage Precautions Never operate or store the equipment in the following environmental conditions as doing so may cause malfunction damage or deterioration which could result in fire and or injury z In ambient environmental conditions other than those specified temperatures outside the range of 0 to 40 C 32 to 104 F and relative humidity outside of the range of 30 to 90 z Where the device is ex...

Page 3: ...2 1 Contact Signal Interface Card Exterior Front View Fig 2 2 Contact Signal Interface Card Exterior Bottom View Table 2 1 Parts Description Name Description AUX IN D SUB 9 pin female Connector for communication with the UPS When receiving the status signal from the UPS power will also be supplied to the contact signal interface card CONTACTS SIGNAL TERMINAL BLOCKS External status signal connector...

Page 4: ...n the UPS Instruction Manual and shut down the UPS completely CAUTION Before installing the Contact Signal Interface Card the UPS must be completely shut down Inserting the card when the UPS is not shut down completely may result in electric shock 2 Remove the protective cover Remove the cover from the rear panel of the UPS Remove the screws from both locations and then the cover from the UPS Note...

Page 5: ...ting the Contact Signal Interface Card UPS rear panel 4 Secure the Contact Signal Interface Card Secure the Contact Signal Interface Card to the UPS using one of the screws removed in step 2 Insert the remaining screw into the cover securing position to prevent losing it Contact Signal Interface Card Cover securing position Contact Signal Interface Card securing position ...

Page 6: ...AL TERMINAL BLOCKS of the Contact Signal Interface Card to the computer Contact Signal Interface Card AUX IN UPS CARD I F Computer Load devices Connect with the signal cable Communication cable Accessory When the UPS is E11A series Installation of the Contact Signal Interface Card and the UPS setting procedures are now complete Start the UPS according to the procedures in the UPS Instruction Manua...

Page 7: ...the UPS mode settings Note that if the card was factory preinstalled this step is unnecessary Caution If the UPS is set to W S mode the Interface Card cannot be used Also this card cannot be used with power control software SANUPS SOFTWARE that requires a PC I F connector for serial connection If PC shutdown capability is required while using this Card the communication settings in the power contr...

Page 8: ...y the operating mode and modify settings following the procedures described in the UPS Instruction Manual 3 Disable the Automatic startup Verify and change settings following the procedures described in the UPS Instruction Manual For more information about the ring signal startup refer to 6 Special Functions of this manual Fig 4 1 LED display when standalone mode is selected Caution When the UPS s...

Page 9: ...of the Contact Signal Interface Card and the UPS setting procedures are now complete Start the UPS according to the instructions in the UPS Instruction Manual Caution If any load devices were disconnected reconnect them at this time If any settings were modified stop the UPS completely Otherwise any changes in the settings are not validated and will not take effect ...

Page 10: ...ke contact Note 3 Signal output UPS Fault This signal is output when a fault occurs in the UPS Make contact or Break contact Default Make contact Note 3 Note 1 These signal outputs are non voltage contacts with a contact capacity of AC 110V DC 24V 0 2A Note 2 In the case of A11F when using OUTPUT1 2 and supplying the output this Card output a signal Note 3 Low Battery voltage Bypass Output and UPS...

Page 11: ...UTPUT 1 or 2 AC output signal 4 pin com Enabled Factory setting UPS output OUTPUT 1 or 2 AC output signal 4 pin com What is a ring signal A ring signal is a false modem signal sent to the computer s serial port When the computer receives this signal it automatically boots up The serial port and the motherboard of the computer must support the ring signal feature in order to use this function After...

Reviews: