background image

The Professionals Choice

RW800i WiFi Thermostat Instruction

EASY

INSTALL

UNDERFLOOR HEATING

OMA

Summary of Contents for RW800i

Page 1: ...The Professionals Choice RW800i WiFi Thermostat Instruction EASY INSTALL UNDERFLOOR HEATING OMA ...

Page 2: ...on 03 Technical specification 04 Display symbols 05 WiFi connection 06 Function User operation 07 Advanced settings 09 Dimension 10 Installation and wiring instructions 08 Troubleshooting 02 Main functions Guide 01 01 01 02 03 04 05 10 10 11 12 12 13 14 ...

Page 3: ...mp Limit Reached Symbol Advanced Setup Edit Hold Settings Down Up WiFi Key Lock Indicator Floor Temp Room Temp Set Temp Heating On Symbol Temperature Edit Automated Heating Cycle Edit Holiday Settings Edit Time Date Confirm Return Power TEMP HIGH SET ROOM TEMP FLOOR TEMP HOLD h HOLIDAY EDIT SAT FRI THU WED MON TUE SUN WAKE LEAVE RETURN SLEEP LEFT HOLIDAY HOLD SETUP DISPLAY SYMBOLS A smart thermosta...

Page 4: ...hrough the Warmme APP on therir phone by adding them in Device Sharing Only the primary user phone can add or remove other phones Note Only the primary user will have access to all the APP features Note Multiple thermostats can be linked to one phone and also multiple phones can be linked to one thermostat Step 3 Make sure the thermostat is on and your phone has the Warmme APP live on the front sc...

Page 5: ... and return to Home screen Note In holiday mode HOLIDAY LEFT and the days remaining will show on display Set the holiday days to 0 to cancel holiday mode The HOLD feature allows the user to set a specific temperature for a specific length of time Once the time ends the thermostat will automatically revert back into the automated program cycle When the thermostat is powered On Press and the clock sym...

Page 6: ...SLEEP for each day of the week using to select and move on to make changes and to go back if needed To set HOLD mode press and the clock will start flashing Press or to select HOLD Press and hold hours will start flashing Note In hold mode HOLD will show on display Set the hold time to 00 00 to cancel hold mode This thermostat can be programmed to automate your heating cycle The programming is based...

Page 7: ...nd the next period starts the thermostat will adjust the heating to try and reach the new set temperature for that period Note When programing the thermostat the time for each period should run sequentially Note Remember there is no On and Off settings only different temperature settings for each period If you want the heating to not turn on during a specific period set the temperature to 0 for that ...

Page 8: ... initialization 00 1 00 TROUBLESHOOTING DIMENSION MM 87 51 51 42 26 16 60 87 E1 Built in sensor short circuit or disconnected E2 Floor sensor short circuit or disconnected Note 1 x floor sensor is supplied with each thermostat and is located in the bottom of each box If this floor sensor is not connected the thermostat will not function The floor sensor must always be wired in and the probe on the en...

Page 9: ...ided Wire the back section in as shown in the wiring diagram on page 14 Loosen fixing screw on the base of the thermostat and separate front panel from back section 13 14 Caution Ensure power is disconnected when wiring Step 1 Step 2 Step 3 Step 4 Power Load Note This thermostat should be mounted in a standard deep fit 1 gang back box We recommend a 47mm deep back box Heating System ...