background image

Manual

MWS 55 / MWS 88-2 / MWS 10

Microprocessor Weather Station

and 

Sensors 55

with data logger (SD-card)

REINHARDT

 System- und

Messelectronic GmbH

Bergstr. 33, D-86911 Dießen-Obermühlhausen

Tel. 0049 - (0) 8196/934100    Fax 0049 - (0)8196/7005 or 1414

E-Mail: 

[email protected]

http://www.reinhardt-wetterstationen.de

Summary of Contents for MWS 10

Page 1: ...tation and Sensors 55 with data logger SD card REINHARDT System und Messelectronic GmbH Bergstr 33 D 86911 Dießen Obermühlhausen Tel 0049 0 8196 934100 Fax 0049 0 8196 7005 or 1414 E Mail wetter reinhardt testsystem de http www reinhardt wetterstationen de ...

Page 2: ...04 12 2020 von DO Manual MWS 55 MWS 88 MWS 10 and Sensors 55 to table of contents Table of contents 1 Caution 9 1 1 Intended Use 9 1 1 1 Storage 9 1 2 Safety Regulations 9 1 3 Mounting 10 2 Setting Up the Weather Station 10 2 1 Installation of Hardware 10 2 1 1 Overvoltage protection 11 2 2 Software Installation 12 2 3 Starting the Software 13 Table of contents ...

Page 3: ...ssure Sensor 17 3 4 4 The Wind Speed Sensor 18 3 4 5 The Wind Direction Sensor 18 3 4 6 Rain Precipitation Sensor MWS 10 otherwise optionally 18 3 3 7 Global Solar Radiation Sensor MWS 10 otherwise optionally 18 3 4 8 Light Intensity Sensor Lux Sensor Option 18 3 4 9 Ultraviolet radiationsensor UV Sensor Option 19 3 4 10 Additional Sensor 19 3 4 11 Connecting an Additional Sensor 19 3 5 Sensor Acc...

Page 4: ... 4 2 2 1 Bottom side of RMS 55 TTL connectors 43 4 2 3 Bottom side of weather station MWS 10 connectors 45 4 3 USB Port 46 4 3 1 Installing the USB driver 46 4 3 2 Problems with the USB Port 47 4 3 2 1 USB Device was not recognized 47 4 3 2 2 Microsoft Ballpoint instead of MWS USB Virtual COM 48 4 3 3 Clean up used COM Port numbers 49 4 4 TCP IP Port with PoE 51 4 4 1 Reading the data logger over ...

Page 5: ...hooting 79 6 1 Transfer problems 79 6 1 1 Allowed cable lengths 79 6 2 No data wrong baud rate 79 6 2 1 Diagnostic connector for testing the data cable 80 6 3 RS422 RS485 interface 81 6 4 Protocol files weather32 software 83 6 4 1 Fault Log 83 6 4 2 Log file in case of error ErrLog txt 84 6 4 3 Logfile when starting up log dat 84 6 4 4 Show output internal 84 6 5 Problem with Mobotix Cameras 84 7 ...

Page 6: ...tings 98 8 2 1 6 Activate deactivate the internal Lithium cell 99 8 2 1 7 Setting the switching outputs 99 8 2 2 SECURE Mode 99 8 2 3 Requesting the microcontroller 100 8 2 4 Meaning of the listing with 0 105 8 2 5 Order of the MWS 55 Sensors 107 8 2 6 Listing of current sensors 111 8 2 7 Detailed information of each sensor 112 8 3 Ethernet Port 113 8 3 1 Administrator 113 8 3 2 Setting the Statio...

Page 7: ...selectronic GmbH Bergstr 33 86911 Diessen Obermühlhausen Postfach 12 41 D 86908 Diessen Tel 08196 934100 MWS_55_e indb Page 7 geändert am 04 12 2020 von DO Manual MWS 55 MWS 88 MWS 10 and Sensors 55 to table of contents MWS 10 ...

Page 8: ...nd Sensors 55 geändert am 04 12 2020 von DO REINHARDT System und Messelectronic GmbH Fax 08196 7005 and 1414 email wetter reinhardt testsystem de Web http www reinhardt wetterstationen de to table of contents MWS 55 WDS 55 MWS 88 2 RMS 55 DFT 55 GSS 55 ...

Page 9: ...sensirion com fileadmin user_upload customers sensirion Dokumente 2_Humidity_Sensors Application_Note Sensirion_Humidity_Sensors_Handling_Instructions pdf Please also note that the internal backup battery for the clock discharges when the unit is not used for a longer time See also here 1 2 Safety Regulations The instruments are manufactured according to modern technical standards and can be opera...

Page 10: ...ction Mount the weather station on a 1 pipe Orient the North marker to North and clamp MWS 55 in place with the two pre mounted high quality steel screws Take care that the pipe is mounted as perpendicularly as possible otherwise the windvane will not work properly and will preferably rotate in one direction N B The wind vanes of the MWS 55 weather station are very sensitive sensory equipment whic...

Page 11: ...n a short period of time Also don t forget to protect the plug of the cable from moisture by covering it when removing the weather station for calibration i e In this case also remove the wall adaptor of the power supply to ensure that no voltage is applied to the contacts of the weather station s plug when it is not used Otherwise the plug will start corroding due to moisture and the cable has to...

Page 12: ...TER EXE in the Weather USB Stick s root directory Now you follow the further instructions Note The weather 32 software creates the HKEY_CURRENT_USER Software ReinhardtGmbH Wet ter key in the registry which is only created when running and is not deleted when the software is uninstalled After the software has been installed you connect the 7 pole plug to the POWER connector of the MWS 55 To perform...

Page 13: ... on the hard disk This is important for reading out the datalogger later If there is no data file on the hard disk the datalogger cannot be read out as the software does not find a start date NOTE MWS 55 only starts recording data to its datalogger after the time has been set This guarantees that the datalogger holds only data with the correct time The clock of the weather station is preset to CET...

Page 14: ... power failure the clock of MWS 55 is kept running and doesn t need to be set when power is applied again Due to power failure there are data missing in the data files time gaps These gaps are filled with dummy values 99999 by the weather32 software when reading the logger So missing data are indicated by measure values of 99999 in the datafile The software then re cognizes in the values of 99999 ...

Page 15: ...he MWS 55V is used only sometimes and is not used at the weekends for example 3 3 Maintenance Because of its elaborated sensors MWS 55 needs no maintenance There are wear parts like the ball bearings and the fan which have to be replaced from time to time These parts have got a life time of app 5 6 years under normal environment conditions Extreme conditions operation directly at the sea high moun...

Page 16: ...system de Web http www reinhardt wetterstationen de to table of contents The rain sensor should be checked regularly for dirt and insect infestation on the seesaw to ensure that it is working properly at all times Depending on the surrounding vegetation and occurrence of spiders wasps etc this should be done weekly but at least monthly Below you can see 2 examples of dirty rain sensors ...

Page 17: ...or is also mount ed on the lower side of the weather station A Gore Tex cover protects it from pollution or destruction by dust or insects The humidity sensor can be used in a tem perature range be tween 40 C to 60 C It is linearized to an accuracy of 2 Range from 10 to 100 measuring accuracy 2 display also as dewpoint meas ure ment in C or F NOTE Thissensorisveryresponsivetostaticchargeandairpoll...

Page 18: ...nd direction Wind direction is given in with 90 being East 180 being South 270 being West and 0 being North Range in 360 measuring accuracy 5 starting speed 0 8 m s hysteresis 8 Output is performed as WR current winddirection and WV main wind direction within a storage interval The value of WV at wind speed WG 0 is 99997 This indicates that a calculation of main wind direction is not possible when...

Page 19: ...t is applied to pin6 and pin7 of the additional sensors socket The sensors output has the sensor identifier ZC in that case sensor ZB can t be used in paralled to the current measurment Additional sensors can be voltage supplied by the weather station as long as their current con sumption is below 100 mA NOTE If current consumption exceeds this value we cannot grant that MWS 55 weather station wor...

Page 20: ...from 950 hPa to 1050 hPa in 0 01 hPa resolution Absolute pressure from 300 hPa to 1100hPa in 0 01 hPa resolution Precipitation from 0 to 5000 mm with 0 1mm resolution Wind direction 0 to 360 resolution 0 025 Wind speed in km h from 0 to 200 km h with 0 01 km h resolution Global radiaion from 0 to 1300 W m Spectral range 0 3 2 8µm Light intensity from 0 to 220000 Lux Spectral range human eye respon...

Page 21: ...sor at a re spective analog value Example Expose a temperature sensor to 0 C aus wait until the sen sor has adapted to this temperature and then you see the respective raw value i e 12500 You proceed with e g 30 C etc Note these pairs of values and replace the resprective lines in the adjustment file It is most im portant that the first pair of values e g L5 1 F must contain the lowest voltage and...

Page 22: ...MWS 55 MWS 88 MWS 10 and Sensors 55 geändert am 04 12 2020 von DO REINHARDT System und Messelectronic GmbH Fax 08196 7005 and 1414 email wetter reinhardt testsystem de Web http www reinhardt wetterstationen de to table of contents ...

Page 23: ...age 23 geändert am 04 12 2020 von DO Manual MWS 55 MWS 88 MWS 10 and Sensors 55 to table of contents Chose the file for transfer to the wea ther station After chosing the file click into the window to start the transfer Sending the file to the weather station now is running When errors occur the error codes will be highlighted in red text color ...

Page 24: ...be in between the min and max values i e raw value 500mV and temperature 10 C L5 2 F8002 und L5 2 W10 Thecalibrationvaluepairsforthelastbasicvalueare rawvalue2400mVandtemperature 200 C L5 3 F38409 und L5 3 W200 Between these basic values the real measured values are calculated by simple cross multiplication I e if the raw value is 19500 you ll need the calibration value pairs 2 and 3 Calculation 3...

Page 25: ...h Defines the previously saved configuration needs to be recovered Thisisperformedwiththecommand ADMINLOADCONFIG Thistakesapp 20 minutes Now a Bootloader update must be performed MWS_BOOTV3_0230 hex At last send following commands to the station Appendix command XW0007c9e0 504b39bb06c1507e22aa37b60000000000 ER10 0 CLEAR These commands are contained in the file MWS_APPENDIXV3_0230 hex Openthisfilew...

Page 26: ...MWS 55 MWS 88 MWS 10 and Sensors 55 geändert am 04 12 2020 von DO REINHARDT System und Messelectronic GmbH Fax 08196 7005 and 1414 email wetter reinhardt testsystem de Web http www reinhardt wetterstationen de to table of contents ...

Page 27: ...Messelectronic GmbH Bergstr 33 86911 Diessen Obermühlhausen Postfach 12 41 D 86908 Diessen Tel 08196 934100 MWS_55_e indb Page 27 geändert am 04 12 2020 von DO Manual MWS 55 MWS 88 MWS 10 and Sensors 55 to table of contents ...

Page 28: ...MWS 55 MWS 88 MWS 10 and Sensors 55 geändert am 04 12 2020 von DO REINHARDT System und Messelectronic GmbH Fax 08196 7005 and 1414 email wetter reinhardt testsystem de Web http www reinhardt wetterstationen de to table of contents ...

Page 29: ...Messelectronic GmbH Bergstr 33 86911 Diessen Obermühlhausen Postfach 12 41 D 86908 Diessen Tel 08196 934100 MWS_55_e indb Page 29 geändert am 04 12 2020 von DO Manual MWS 55 MWS 88 MWS 10 and Sensors 55 to table of contents ...

Page 30: ...wer consumption 1 28W Current at 8VDC 145mA power consumption 1 16W Current at 10VDC 110mA power consumption 1 10W Current at 12VDC 100mA power consumption 1 20W Current at 15VDC 83mA power consumption 1 25W Current at 18VDC 70mA power consumption 1 26W Current at 24VDC 56mA power consumption 1 34W Typical power consumption of MWS 10 with fan but without additional sensors and with fully charged a...

Page 31: ...600BAUD 8bit no parity and one stop bit For eva luation with your own software you can set several output modi see appendix CAUTION When changing the order of sensors there may special sensor properties to be changed additionally If you don t perform in the right way this may result in wrong data output or wrong measurement The datastring ends with CR LF each datastring which is written in the int...

Page 32: ...indow with different commands To perform send the command shell in a terminal software like hyperterminal putty or any other terminal program The weather station then switches into the command window PLEASE NOTE THAT THE STATION DOES NOT STORE ANY DATA INTO THE LOGGER WHILE IT IS IN THE COMMAND WINDOW Paths must be separated with slash not with backslash To exit the shell type EXIT and then press ...

Page 33: ...HELP MD MKDIR MOUNT REN SHELL TYPE WRITE 3 10 1 2 Description of the commands ATTRIB R R A A H H S S name Changes the attributs of a file or directory The attributs must be typed in capital letters The order doesn t matter R Set to Read Only R Remove Read Only A Set to Archiv A Remove Archiv H Set to Hide H Remove Hide S Set to System S Remove System CD name Change path into directory CHDIR name C...

Page 34: ...and has always got the size 0 bytes EXIT Exits the Command Shell FORMAT logi drv part type bytes clust Formats the SD card and creates a new file system FAT CAUTION Formatting is performed without warning logi drv is the drive part type is the patitioning rule 0 FDISK 1 SFD bytes clust are the allocation units i e formatting a memory card FORMAT A 0 4096 FTIME HHMMSSDDMMYY name Changes the file or...

Page 35: ...t file _system save config sav If there already is a config sav file it will be saved under config bak in the same directory 3 10 1 4 Load settings from the SD card ADMIN LOAD CONFIG Loads the file _system save config sav and integrates the contained settings into the FLASH memory Thistakesabout20minutes Ifthecommandwassentviatheserialport aprogressbarisdisplayed LOAD CONFIG I Each stands for 1 ea...

Page 36: ...nterface connector computer Pin 1 GND Pin 5 GND Pin 2 GND used for MWS 10 Pin 3 RXD MWS Pin 3 TXD PC Pin 4 TXD MWS Pin 2 RXD PC Pin 5 VCC 18VDC Pin 6 R with RS422 485 Pin 7 T with RS422 485 Connect Pin 4 and 6 Connect Pin 7 and 8 The data cable can be lengthened to up to 150 m at 9600baud under optimum conditions and with suited cable not in industrial environment see also 6 1 1 Allowed cable leng...

Page 37: ...ing VCC PSU 18VDC Pin 4 free Pin 5 free 4 1 2 1 Connection Diagram Cable for heating device NOTE The cable for the heating is 10 m long and can neither be lengthened nor shortened A GPS receiver is connected to an MWS 5M with heating via the combined socket for GPS and heating with 2 separate cables and a special adaptor 4 1 3 Allocation of the Connection Cable for GPS Receiver Garmin GPS 18x LVC ...

Page 38: ...WS 55 Heating and GPS connection 1 x 5 pole connector 5 pole connector Pin 2 GND Heating GND PSU 18VDC Pin 3 VCC Heating VCC PSU 18VDC Pin 1 GND GPS Garmin GPS18x LVC GND Pin 4 Signal GPS Garmin GPS18x LVC Out Pin 5 VCC GPS 10 24VDC Garmin GPS18x LVC VCC 4 1 5 Allocation of the Connection Cable for Sensors with RS422 port 7 pole connector MWS 55 power supply and data connection Pin 1 GND PSU GND g...

Page 39: ...stfach 12 41 D 86908 Diessen Tel 08196 934100 MWS_55_e indb Page 39 geändert am 04 12 2020 von DO Manual MWS 55 MWS 88 MWS 10 and Sensors 55 to table of contents 4 1 6 Allocation of the 1 1 cable for sensors with RS232 port 4 1 6 Allocation of the 1 1 cable for Sensors with RS422 port ...

Page 40: ... geändert am 04 12 2020 von DO REINHARDT System und Messelectronic GmbH Fax 08196 7005 and 1414 email wetter reinhardt testsystem de Web http www reinhardt wetterstationen de to table of contents 4 2 Pin assignments 4 2 1 Allocation of the MWS 55 Connection Sockets ...

Page 41: ...33 86911 Diessen Obermühlhausen Postfach 12 41 D 86908 Diessen Tel 08196 934100 MWS_55_e indb Page 41 geändert am 04 12 2020 von DO Manual MWS 55 MWS 88 MWS 10 and Sensors 55 to table of contents 4 2 1 1 Allocation of the RMS 55 TTL Connection Sockets ...

Page 42: ...ttp www reinhardt wetterstationen de to table of contents 4 2 2 Bottom side of weather station MWS 55 MWS 88 2 connectors Caution Protect all unused sockets with the protective caps to avoid corrosion of the contacts When removing the weather station in case of recalibration or other cases it is essen tial to protect the cables from rain and unplug all power supplies to avoid corrosion of the cont...

Page 43: ...al MWS 55 MWS 88 MWS 10 and Sensors 55 to table of contents 4 2 2 1 Bottom side of RMS 55 TTL connectors Caution Protect all unused sockets with the protective caps to avoid corrosion of the contacts When removing the weather station in case of recalibration or other cases it is essen tial to protect the cables from rain and unplug all power supplies to avoid corrosion of the contacts ...

Page 44: ...d Sensors 55 geändert am 04 12 2020 von DO REINHARDT System und Messelectronic GmbH Fax 08196 7005 and 1414 email wetter reinhardt testsystem de Web http www reinhardt wetterstationen de to table of contents This page is left free for further expansions ...

Page 45: ...33 86911 Diessen Obermühlhausen Postfach 12 41 D 86908 Diessen Tel 08196 934100 MWS_55_e indb Page 45 geändert am 04 12 2020 von DO Manual MWS 55 MWS 88 MWS 10 and Sensors 55 to table of contents 4 2 3 Bottom side of weather station MWS 10 connectors ...

Page 46: ...can provide a higher current at it s output for sup plying the MWS 55 The MWS 55 needs at least 150mA at the USB port without fan If the fan is active the MWS 55 draws up to 400mA for a short time from the USB port Continuousoperationwithfandrawsapp 300mA from the USB port On that score the MWS 55 disables it s fan when running at the USB port and the serial port RS 232 is being disabled by defaul...

Page 47: ...e was not recognized As mentioned above there may occur problems recognizing and installing a MWS 55 connected to the USB port due to too high current consumption at the USB port The MWS 55 cannot be recognized and installed correctly IntheDeviceManager Windows Key BREAK there is no MWS USB Virtual COM Port installed but under USB Controller as Unknown device a new device has been created To remed...

Page 48: ...l This results in malfunction of the driver for the MWS 55 The problem may be solved by a change in the registry To perform you start the registry editor by pressing the WINDOWS KEY R and then type re gedit and press OK In the next window you choose YES In the Registry editor you navigate to the following key HKEY_LOCAL_MACHINE System CurrentControlSet Services Sermouse and right click on Start an...

Page 49: ...ved virtual COM ports listed in your system so there may be numbers of 20 30 or higher ThishappenswhenoftenconnectingdifferentUSBdevices to the computer installing drivers creating a virtual COM port On the right you see an example of a system with many reserved COM ports Youcancleanupthesereservedportnumberswithalittlechange in the registry To perform you start the registry editor by pressing the...

Page 50: ...8 MWS 10 and Sensors 55 to table of contents Under Value data a set bit makes a port number 1 Byte 01 COM1 FF COM1 COM8 2 Byte 01 COM9 FF COM9 COM16 and so on Select all values If you want to clear up all values insert a 0 for all values Close the Registry editor and then restart your computer All COM ports except the installed devices are free now You may reinstall the dirvers for your USB device...

Page 51: ...logger over PoE TCP IP In PoE mode TCP IP there is a limitation reading the data logger The transmission rate set for the serial port is also valid for the transmission over TCP IP If this speed is too high a buffer overflow may occur causing that not all data in the data logger can be transmitted over the TCP IP interface This leads to gaps in the data file Therefore the transmission rate should ...

Page 52: ... be stored Example of establishing a connection FTP Command overview FTP Server Weather station Client Administrator Cmd Description Ask for connection on FTP port 21 USER Transmit user Accept connection 220 MWS GRANTED ADMIN PASS Transmit password ACCT User identifier Send command USER ADMIN QUIT Close connection PWD Output current directory User OK 331 NEED PASSWD NOOP No operation PASV Request ...

Page 53: ... up downloads of data from a server and also from MWS 55 with PoE option You ll find FileZilla here https filezilla project org After you installed FileZilla create a new server under File Site Manager Select New Site and insert the MWS 55 IP address unser Host i e 192 168 240 95 you don t need to insert the port Under Logon type you choose if the password 7 char serial of MWS 55 i e 1033123 is ne...

Page 54: ...ic GmbH Fax 08196 7005 and 1414 email wetter reinhardt testsystem de Web http www reinhardt wetterstationen de to table of contents It is very important to set the transfer mode under Transfer Settings to PASSIVE See below Finally click to Rename to give a name to the new site Now you can access the MWS 55 by clicking on Connect ...

Page 55: ...Also the Ethernet port must be enabled F 24 or ADMIN SET PERMIT 15 ON or being configured This already is preconfigured when ordering a station with TCP IP PoE option It is important that at the access permissions with ADMIN SET INCLUDE the connection type HTTP or HTTP for privileged access is added Access from an IP MAC address not being enabled for this connection type will get no answer A HTTP ...

Page 56: ...Allgemeiner Style Sheet Ordner CSS Style Sheets JS Allgemeiner Java Script Ordner JS Java Scripts ADMIN Ordner in dem sich Dateien Ordner befinden die ausschließlich von der Administrator Adresse aufgerufen werden können INDEX HTM Optionale Landeseite für die Administrator Adresse HTM Weitere HTML Seiten und Text Dateien für die Administrator Adresse TXT RTF XML IMAGES Optionaler Bilder Ordner nur...

Page 57: ...T INCLUDE 192 168 100 x HTTP and two privileged users set by ADMIN SET INCLUDE 192 168 100 10 HTTP and ADMIN SET INCLUDE 192 168 100 11 HTTP If the computer with IP address 192 168 100 25 opens the browser and the station s IP address is entered there the browser initiates a HTTP GET request i e GET HTTP 1 1 The station recognizes as landing page index htm and the Administrator s IP address so at ...

Page 58: ...ather station then will compare this password with the stored passwords nimdA pvpass1 pvpass2 stdpass and grant access to the respective folder it the password matches with one of the stored passwords Typically this command is submitted as a request with the POST method i e form action login htm method post label for pass Please insert password label input id pass name MWS HTTP PASSWD maxlength 15...

Page 59: ...ead So after creating the local paths can bekept i e inthepictureontheright side in line 7 also may be written href meinstyle admin css orinline 9 the local Jave Script folder java heißen src java senscfg js Tips Already when creating files regard the length of the file names max 8 characters 3 characters suffix 8 3 Using many templates or pics increases the load time of HTML pages for the WEB ser...

Page 60: ...il wetter reinhardt testsystem de Web http www reinhardt wetterstationen de to table of contents 4 4 3 3 WEB Page current Data This page shows an overview with sensors set under index htm The appearance of the sensors is controlled with control commands for output storing 4 4 3 4 WEB Page current Data 2 This page shows an overview with sensors set under sens2 htm ...

Page 61: ...ssen Tel 08196 934100 MWS_55_e indb Page 61 geändert am 04 12 2020 von DO Manual MWS 55 MWS 88 MWS 10 and Sensors 55 to table of contents 4 4 3 5 WEB Page Min max Here the maximum and minimum values are listed 4 4 3 6 WEB Page Ethernet Here the Ethernet settings are listed Here you also can perform settings ...

Page 62: ...on DO REINHARDT System und Messelectronic GmbH Fax 08196 7005 and 1414 email wetter reinhardt testsystem de Web http www reinhardt wetterstationen de to table of contents 4 4 3 7 WEB Page Station Lists the station s settings 4 4 3 8 WEB Page Sensor configuration Lists the sensor s settings ...

Page 63: ...le of contents 4 4 3 9 WEB Page Terminal Allows controlling and reading the station via a terminal with a command line Caution The ADMIN commands which are look like ADMIN GET ETHER input via an external terminal software putty hypertrm must be typed without the leading in here The terminal window does not refresh automatically but needs to be refreshed by the Refresh or Send button or with the re...

Page 64: ...can not be formatted MWS GET ETHERNET GATEWAY Outputs the specified IP address of the gateway see ADMIN ETHERNET GATEWAY The output can not be formatted MWS GET ETHERNET NAME Returns the specified IP address of the name server see ADMIN ETHERNET NAME The output can not be formatted MWS GET ETHERNET CONNECTION x This command outputs one x 1 20 of the 20 possible connections The first 16 are TCP con...

Page 65: ...ization point of the current user with y and if it matches outputs the test enclosed in apostrophes following the Optionally an alternative text following a also enclosed in apostrohes can be output if no match is found Both texts must not exceed 50 characters and the complete command MWS must not exceed 120 characters MWS GET HTTP DATA x since V3 0242 Returns the value of the 8 bit global variabl...

Page 66: ...decimal number MWS GET d MWS GET STATION NAME Returns the station s name see ADMIN STATION NAME MWS GET STATION LOG UPDATE Returns the storage interval of the data logger in seconds usually as decimal number MWS GET STATION LOG CAPACITY Returns the size of the remaining free memory in kByte usually as decimal number MWS GET STATION LOG LIMIT Returns the total size of the memory in kByte usually as...

Page 67: ...sensors with time or date sensor number 64 66 or DATA 13 oder DATA 14 By default the time is formatted as 02d 02d 02d the date as 02d 02d 04d what is resulting in output hh mm ss or dd mm yyyy Formatting the output For most MWS GET commands that output numbers the format can be changed by inser ting apostrophes after GET It is crucial whether an integer value or a floating point number is to be ou...

Page 68: ...ontents Examples of formatting MWS HTTP TERM 0 Returns a link to REINAHRDT Web page a href https www reinhardt testsystem de REINHARDT System und Messelectronic GmbH a MWS HTTP TERM 1 Returns REINHARDT System und Messelectronic GmbH MWS HTTP TERM 2 Returns the device identifier as string see also DI i e MWS 10 MWS HTTP TERM 3 Returns the device version as string see also DV i e 1 20 MWS HTTP TERM ...

Page 69: ...r hh mm ss i e MIT 04 MAI 2011 14 00 00 MWS HTTP TERM 13 Returns the UTC time and date of the station ger in the format Day of week Day Name of month Year hh mm ss i e MIT 04 MAI 2011 13 00 00 GMT MWS HTTP TERM 14 Returns the local time of the station in the format hh mm ss i e 14 00 00 MWS HTTP TERM 15 Returns the local date of the station in the format dd mm yyyy i e 04 05 2011 MWS HTTP TERM 16 ...

Page 70: ...hours or until the station receives the command MWS HTTP LOG OFF MWS HTTP LOG OFF since V3 0242 MWS HTTP LOG OFF Deletes the access authorization to the contents of the HTPASS folder of the current MAC address from the 16 digit authorization memory so that the current user can only call files outside of this folder which ones depend on the respective authorization and access type eg administrator ...

Page 71: ...N ADDRESS 192 168 1 2 executes the command ADMIN SET ADDRESS 192 168 1 2 and thus sets the administrator IP address MWS ETHERNET MWS ETHERNET Access to all ADMIN ETHERNET commands i e MWS ETHER IP 192 168 1 9 or MWS ETHER IP 192 168 1 9 executes the command ADMIN ETHERNET IP 192 168 1 9 and thus sets the IP address of the station MWS STATION MWS STATION Access to all ADMIN STATION commands i e MWS...

Page 72: ... von DO REINHARDT System und Messelectronic GmbH Fax 08196 7005 and 1414 email wetter reinhardt testsystem de Web http www reinhardt wetterstationen de to table of contents 4 4 4 Pin assignments of the PoE connector The RJ45 connector of the networkcable is wired according to EIA TIA 568B ...

Page 73: ...oE When there are problems in data transmission with PoE or the connection frequently is interrup ted you may reduce the speed of data transmission To reduce the speed from 100M Full Duplex to 10M Full Duplex send the following command to the station via a terminal program XW0007c9ec 58f500 To switch back to automatic connection speed send the following command XW0007c9ec 5d0000 After these settin...

Page 74: ...a WEB Interface If you did not specify a IP address when ordering your weather station with internal WLAN op tion the IP address is set to 192 168 240 93 24 SSID is WETTER and security is none see XML file xPico_set_ 192_168_240_93 txt on stick This IP address takes you to the WEB interface of the WLAN module xPico Wi Fi where you can perform all necessary settings Further information can be found...

Page 75: ... standard cable into the configuration port for WLAN WLAN settings on the weather station Now press the x key in the terminal program within the next 3 seconds until you receive a message from the WLAN module in the terminal program up to 10 seconds Then immediately press the ENTER key Now you are in the serial interface of the WLAN module By entering a you receive a list of the possible commands ...

Page 76: ...ram TeraTerm https tera term en lo4d com windows recommended by Lantronix also included on the weather stick and activate the xPico WLAN module as described here You ll find a sample file in the TeraTerm folder in the weather stick s software directory which contains the basic settings for the xPico WLAN module xPico_set_ 192_168_240_93 txt You may adapt this file to your specifications and save i...

Page 77: ... operation parallel operation with the serial cable via the RS 232 interface is possible at any time However please note that command collisions can occur with controlling access via wireless LAN and the RS 232 interface e g when reading out the data logger Example If the command to read out data logger is sent via the RS 232 interface the station will start to output the data from the logger If a...

Page 78: ...tive measures will prove useless if radio medium frequency transmitters are around 2 2 2 Measuring field The measuring field ought to be 10 x 10m but at least 6 x 6m 3 Sensors 3 1Measuring air temperature 200cm By standard air temperatur is measured 2m above ground In order to keep radiation errors as low as possible air temperature ought to be measured in a weather hut 3 4Measuring relative air h...

Page 79: ... should use shielded cable or use RS422 Interface Further hints you ll find on the CD under FAQs 6 2 No data wrong baud rate If you accidentally set the baud rate to a wrong value or the weather station does not respond to any command you may try the follwing procedure to get access to the weather station again Start a terminal program with 9600baud 8bit no parity no protocol Then you send exclama...

Page 80: ...ther then the cable or the power supply unit can also have a defect For this purpose we can provide you with a diagnostic connector on request for checking the cable and the power supply To check the cable and the power supply unit plug the data cable into the diagnostic connector and plug the power supply unit into a socket If the LED on the diagnostic connector lights up the power supply unit an...

Page 81: ...utput is tri state Data only will be sent on request with the correct address Initalization and memory check with RS485 are performed as well but without sending any data for the output is disabled tri state While initializing after power up the weather station doesn t respond to any commands for app 10 seconds For controlling the weather station with RS485 the address of the weather station must ...

Page 82: ...nd Sensors 55 geändert am 04 12 2020 von DO REINHARDT System und Messelectronic GmbH Fax 08196 7005 and 1414 email wetter reinhardt testsystem de Web http www reinhardt wetterstationen de to table of contents This page is left free for further expanses ...

Page 83: ...g commands errors RoC reset after number of critical errors see also ER RoL reset after number of less critical errors see also ER Especially for resetting the MWS 55 after a certain number of errors the command ER roc rol clear has been created This command allows to write the number of errors into the NV RAM Default for roc 10 reset after 10 critical errors and rol 0 no reset after less critical...

Page 84: ...oblems Caution This log file is overwritten each time when the software is restarted To keep this file store it in another place or rename it 6 4 4 Show output internal In the software under VIEW and SHOW OUTPUT the software lists all communication with the weather station since the programm was started Also the commands sent within the terminal window of the weather32 software will be listed This...

Page 85: ...d an overview of the connectors of Sensors series 55 with switching outputs These sensors are based onto the WSA Warning signal alert Further details you ll find in the respective manual of WSA The cable option for connecting the switching outputs has the following connections GND Pin1 grey 5VDC switched Pin2 pink Switching contact 1 Pin3 green yellow Switching contact 2 Pin4 white brown The switc...

Page 86: ...Messelectronic GmbH Bergstr 33 86911 Diessen Obermühlhausen Postfach 12 41 D 86908 Diessen Tel 08196 934100 MWS_55_e indb Page 86 geändert am 04 12 2020 von DO Manual MWS 55 MWS 88 MWS 10 and Sensors 55 to table of contents ...

Page 87: ...n a table For indoor use only 7 3 GPS Receiver When performing mobile measurements at different locations the position data on which the measurements were carried out may be important For this case we offer a GPS receiver Garmin GPS18x LVC 5V for storing the position data altitude and accurate time The longitude has got the identifier GX the latitude the identifier GY A data set of stored data loo...

Page 88: ...ng an additional sensor PLEASE NOTE 13 stands for ASCII characater 13 Carriage Return The command can also be closed with 13 10 CARRIAGE RETURN LINE FEED i e CR LF Changing from Measured Value output and Adjustment Mode output of raw values W 13 Transmitting the linearisation data L SENSORNUMBER INDEX 1 8 F RAW VALUE 13 L SENSORNUMBER INDEX 1 8 W ANALOGVALUE 13 E g You measure 30540 V at 24 5 C fo...

Page 89: ... stopp bit B6 8 E 2 13 or 38400Baud 8bit odd parity 1 stopp bit B7 8 O 2 13 Avoiding automatic changing of BAUD rate BX AUTO OFF where X is the desired BAUD rate see above Continue reading the logger after an interruption C 13 Reset after errors setting the error memory ER roc rol CLEAR since V3 0230 Setting the number of critical erros roc or less critical errors rol after which the watchdog rese...

Page 90: ...g GT aresenttotheGPS orsecondarystation at the GPS input This command can simply be abbreviated to in GPS configuration mode GT e g setting the clock of secondary station U075500111214 Gx CLEAR 13 remove GPS RS232 sensor remove from processing since V3 0118 Gx GPGGA 9 13 configure GPS sensor GPGGA data set value after 9 delimiter Gx GPRMC 5 13 configure GPS sensor GPRMC data set value after 5 deli...

Page 91: ... is enabled Attenuation for sensors enable disable Kx MW1 13 Sensor with output number x is strongly averaged Kx M0 13 Average off for sensor x Attenuation for sensor output enable disable Kx A1 1 1 13 Sensor with output number x is not averaged Kx A1 2 1 13 Sensor with output number x is averaged Attenuation for sensor storage enable disable Kx A1 1 1 13 Sensor with output number x is not average...

Page 92: ...n integer value containing informations regarding group number of unit and internal unit storage position for the controller also stores these informations as integer value and reads these values from the unit ini at startup So it is important not to insert new units in the middle of the unit ini but only add new units at the end of the file Otherwise the allocation of the units will be mixed and ...

Page 93: ...imit value lower limit value lower limit Kx OZ1 13 Sensor position x 1 32 establish circular reference of limitation Falling limitated value value upper limit lower limit UG 1 UG OG OG 1 Rising limitated value value upper limit lower limit OG 1 OG UG UG 1 Caution Circularreferencehasgoteffectsontotheaveragecalculation see wind average Kx SMy y 13 Sensor position x 1 32 averaging coefficient for av...

Page 94: ...output runs normal otherwise the dependentsensorpostioniscalculatedwiththetermatfirstandiftruethe value is updated Optionally attenuated real value minimum maximum average and standard deviation can be switched to the real sensor s value i e K5 D A1 4 6 additionally swiches min and max 8 2 1 3 Linearisation calibration data Sending linearization data L SENSORNUMBER INDEX 1 8 F RAW VALUE 13 L SENSO...

Page 95: ...simple XOR or CRC 8 Bit21 1 1xxxxxxxb bit8 Flashwriteprotection Commandschangingthedataflashare rejected except update This mode only can be cancelled in SECURE Mode xxxxxxxx 1xxxxxxx xxxxxxxxb bit16 SuppressesresetoutputsontheGPS RS 232port whichare sent by default since V3 0222 xxxxxxx1 xxxxxxxx xxxxxxxxb bit17 Standard protocol Sets RS 485 full duplex to suppress the waitingtimein normal RS 485...

Page 96: ...om RS422 S1 to RS485 S2 first change into SECURE mode with the command The MWS 55 now will send permanently the following SECURE Then you send the command S2 The MWS 55 now is in RS485 mode and has got the preset address 10 by default To exit the SECURE mode insert the following command 10 Now you can retrieve the current data string with the command 10U To change back to RS422 first switch to SEC...

Page 97: ...gstr 33 86911 Diessen Obermühlhausen Postfach 12 41 D 86908 Diessen Tel 08196 934100 MWS_55_e indb Page 97 geändert am 04 12 2020 von DO Manual MWS 55 MWS 88 MWS 10 and Sensors 55 to table of contents This page is left free for further expansions ...

Page 98: ...XW0007c9ec 5f6200 10M Full Duplex XW0007c9ec 58f500 100M Full Duplex XW0007c9ec 5ba600 Auto standard XW0007c9ec 5d0000 Set storage interval for data logger Z INTERVAL in 10 Seconds steps 13 0 Logger off Valid values 1 8640 ZD INTERVAL in 2 Seconds steps 13 0 Logger off Valid values 1 43200 ZS INTERVAL in 1 Seconds steps 13 0 Logger off Valid values 1 86400 Examples Z1 13 stores a data set every 10...

Page 99: ...ts following commands with different parameters are available Vx TERM hour Term1 linking Term2 linking Term3 linking Term4 13 Sets the output term of virtual sensor x 9 16 hour either numbers 0 23 or 8 18 or 0 23 always separated by comma i e 11 12 13 20 or 6 19 Optional direcly subsequent Default Sets or deletes the output if the time is out of the set hours 1 or 0 inhibit Minimum on time in minu...

Page 100: ...e 33 x 20 DISK I O failure 13 42 30 12 10 285 20 DISK I O failure 13 43 24 12 10 285 18 I2C line state The value after ERROR is the complete number of entries in the list CO complete number of errors CC number of critical errors PIO failure SPI initialisation Memory errors and disk errors CL number of less critical errors initialisation errors transmission errors of RTC ADC UARTs USB I C and Ether...

Page 101: ...Internal 02 Sensor 58 Mode Timer Gain 1 0000 Transl 0 0000 e g I3 Rain counter Internal 03 Sensor 59 Mode Counter Reset none e g I4 Counter Timer Analogue Internal 04 Sensor 60 Mode Analog Read Linearisation table x 1 32 e g L1 Temperature Lx 13 Alias x Sensor position x 1 32 read values e g K2 Temperature Kx 13 02 TE Name Temperature Unit F 1 810000 32 000000 Value Real 26 5311 Smooth 26 5231 Raw...

Page 102: ...AS5048B 07 001 TSL4531 08 001 TCS3414CS 09 128 STS21 10 001 BMP280 11 001 BMP280 12 000 13 000 14 001 AS5601 15 001 AS5601 16 000 17 000 18 000 19 000 20 000 21 000 22 000 23 000 24 000 25 000 26 000 27 000 Read special sensor x Sx 1 27 Sx 13 Example S3 Pressure sensor BMP180 Temperature I2C 03 Source BMP180 Value Raw 30348 0000 The 3 digits numbers are the I C flags of each sensor 000 Sensor not ...

Page 103: ...t of settings of sensor 78 Digital output 7 Heating_device_2 This one is fed by 3 sensors 1 Sensor 00 TE 2 Sensor 00 TE 3 Sensor 58 WG and has got the value 1 or 0 depending on if term TE 10 OR TE 0 AND WG 10 is true or false within time from 0 00 to 23 59 Request virtual sensor x 17 32 Example V17 Virtual Tab 17 Sensor 80 Sources 01 02 03 04 Sensor 02 Sensor 01 Sensor 67 Sensor 03 Calc Opt 0 Calc...

Page 104: ...08196 7005 and 1414 email wetter reinhardt testsystem de Web http www reinhardt wetterstationen de to table of contents Read all configuration data 13 0 13 Output of main information 1 13 Output of information about the single sensors 2 13 Output of information about sensor 2 temperature 3 13 Output of information about sensor 3 humidity etc ...

Page 105: ...R_EXT_MEMORY Memory card detected but not responding Bit 6 Reserved Bit 5 Reserved Bit 4 Reserved Bit 3 ERR_GPS_TIME No GPS time set in current hour until now Bit 2 ERR_5V no 5V from USB Bit 1 ERR_VIN Input voltage too low leading UNDERVOLTAGE FL Flags Bit 6 8 Reserved Bit 5 GPS_ONLINE GPS or RS232 Sensors ready Data string received Bit 4 GPS_CFG_MODEGPS Configure mode active Data at GPS Input are...

Page 106: ...eleted after request Bit 6 SCI_PAR_ERR Parity Error is deleted after request Bit 5 Reserved Bit 4 Reserved Bit 3 SCI_TX_ENA Sender active Bit 2 SCI_RX_ENA Receiver active Bit 1 TERMINATION Instruction termination Carriage Return received TZ Time Zone UTCtoRTC 12 13 AUTO shows that automatic DST switching is active DST shows that daylight savings time is set AT Attenuation not used HZ Value for act...

Page 107: ...ional sensor 3 off mV 17 ZD Additional sensor 4 off mV 18 ZE Additional sensor 5 off mV 19 UB Supply voltage on V 20 UV UV Radiation off mW m 21 LX Light intensity off lux 22 DB Barometric pressure on hPa 23 TP Dewpoint on C 24 WC Windchill on C 25 not used off 26 not used off 27 FS Fan Status on 28 GH GPS Altitude off m 29 GX GPS Longitude off 30 GY GPS Latitude off 31 GV GPS Speed off 32 GS GPS ...

Page 108: ...midity SHT35 since V3 0244 FE L2 97 Dependency Tab D1 13 I C Winddirection AS5601 since V3 0244 0 Right spin CW 1 Left spin CCW WR WV 14 I C Magnitude AS5601 since V3 0244 1 AGC value 0 255 MG 15 I C 16 I C 17 I C 18 I C 19 I C 20 I C 21 I C 22 I C 23 I C 24 I C 25 I C 26 I C 27 Ext_AD K16 External AD Converter Channel 1 ZC pin7 L7 102 ZC Optional current input I Channel n c 28 Ext_AD K15 External...

Page 109: ...x 10 Counter Resetval Μicro Pin 13 i e Tacho signal fan 61 Internal Internal AD Converter Channel 2 AD0_1 62 Internal Internal AD Converter Channel 3 AD0_2 63 Internal Internal AD Converter Channel 5 VIN PL Sensoroptions 1 3 since V3 0209 Sensoroptions 4 7 since V3 023 0 AD CVT value 1 Error counter 2 last error code 3 no Batt Voltage 4 number of errors 5 critical errors 6 less critical error 7 an...

Page 110: ...3 S4 2 S1 S2 S3 S4 3 S1 S2 S3 S4 4 Arithmetic mean 85 Virtual 86 Virtual 87 Virtual 88 Virtual 89 Virtual 90 Virtual 91 Virtual 92 Virtual 93 Virtual 94 Virtual 95 Virtual V32 96 Linear K2 Linear Table 1 L1 For TE 97 Linear K3 Linear Table 2 L2 For FE 98 Linear K4 Linear Table 3 L3 For TD 99 Linear K5 Linear Table 4 L4 For DR 100 Linear K14 Linear Table 5 L5 For ZA 101 Linear K15 Linear Table 6 L6...

Page 111: ... 059 RD __ 13 10 13 106 SX __ 13 10 14 100 ZA __ 13 10 15 101 ZB M_ 13 10 16 102 ZC M_ 13 10 17 103 ZD M_ 13 10 18 104 ZE M_ 13 10 19 063 UB __ 13 10 20 014 MG __ 13 10 21 006 LX __ 13 10 22 080 DB M_ 13 10 23 081 TP __ 13 10 24 082 WC __ 13 10 25 041 XX __ 13 10 26 042 YY __ 13 10 27 079 FS __ 13 10 28 035 GH __ 13 10 29 036 GX _P 13 10 30 037 GY _P 13 10 31 063 AE __ 13 10 32 039 GS __ 13 10 13 ...

Page 112: ...tistic Real 13 10 Statistic Reset none 13 10 Calc Opt 0 13 10 Limit Normal 13 10 13 10 Min 200 0000 13 10 Max 1200 0000 13 10 Gain 1 0000 13 10 Translation 0 0000 13 10 Smooth Weight 01 0 100000 02 0 300000 03 0 600000 13 10 Statistic 13 10 Interval 300 300 13 10 Avg Weight 1 000000 13 10 13 10 Dependency 13 10 Alias none 13 10 TERM OFF 13 10 Affects none 13 10 13 10 Linear Tab 04 13 10 Sensor 10 ...

Page 113: ...ress too A MAC address is explicit assigned to a computer or network adaptor ADMIN SET ADDRESS 00 11 22 33 44 55 sets the MAC address and only from this network adaptor administrative commands will be accepted To increase safety both IP address and MAC address can be set simultanely i e ADMIN SET ADDRESS 00 11 22 33 44 55 192 168 100 25 sets the network adaptor with MAC address 00 11 22 33 44 55 a...

Page 114: ...ess getting full access to the weather station See also here The setting is similar to ADMIN SET INCLUDE this means you also can set ranges of addres ses what is not recommendable ADMIN SET PASSWD 123xyz sets the ADMIN password which is used for the ADMIN commands The password can contain up to 15 alpha numerical characters No blanks and must be contained in the password The first character must n...

Page 115: ... tunnel any more that means only via the RS 232 or USB port ADMIN commands can be executed 8 3 5 Closing connections ADMIN REMOVE ETHERNET CONNECTION x closes an Ethernet connection x is the number of the TCP connection to be closed 1 16 see ADMIN GET ETHERNET CONNECTIONS If an is inserted instead of a number all opened TCP and UDP connections will be closed ADMIN REMOVE ETHERNET TCP CONNECTION x ...

Page 116: ...han one address at the same time the first received or the lowest number will be processed and all other commands of other addresses are temporarly blocked except commands from the ADMIN address Commands from the ADMIN address interrupt discard commands from all INCLUDE addresses and will be executed with priority Write accesses should be given sparingly to avoid influences on other clients This p...

Page 117: ...ort To allow additional TCP transmission from port 20002 to this client a TCP has to be added i e ADMIN SET INCLUDE 192 168 3 4 TCP HTTP The following types of connection are allowed to be added and seperated by blank or comma after the TCP TCP connection RS232 tunnel on port 20002 UDP UDP connection RS232 tunnel on port 20002 HTTP HTTP connection on port 80 However no commands will be accepted fr...

Page 118: ... 08 09 10 11 12 13 14 15 ADMIN ETHERNET IP xxx xxx xxx xxx yy This sets the IP address and the net mask of the MWS 55 With IPV4 the 4 bytes must be sepe rated by a 192 168 10 25 The net mask is seperated with or from the IP address and contains the number of the set bits i e ADMIN ETHERNET IP 169 254 100 50 16 sets the IP address of the MWS 55 to 169 254 100 50 and the net mask to 255 255 0 0 ADMI...

Page 119: ...D Connection closed ESTABL Connection established WAITING Connection not longer active waiting for access or closing after 120 seconds STOPPED Connection interrupted ACTIVE Establishing or closing a connection If the connection is not closed the local port weather station the authorisation of the client for this port limited only reading privileged A ADMIN and the client s IP address is displayed ...

Page 120: ...hksum Errs 0 Proto Errs 0 ICMP Rec vd Pkts 0 Sent Pkts 0 Dropped Pkts 0 Type Errs 0 TCP Rec vd Pkts 308 Sent Pkts 307 Resent Pkts 0 Rec vd Rsts 1 Dropped Pkts 0 Chksum Errs 0 Ack Num Errs 0 Conns Ovrflw 0 Conns Bad Ports 0 UDP Rec vd Pkts 0 Sent Pkts 0 Dropped Pkts 0 Chksum Errs 0 8 3 7 Changing the port number With the following command you may change the standard port number to the same port num...

Page 121: ...ds A B D F G I K Only Administrator L O S PF PL V W Full access Full access to V3 0207 CRC P R U Z Administrator Super User Full access Full access later than V3 0207 Administrator Super User Commands Administrator Super User Full access Full access Commands ADMIN Administrator Full access possibly password Super User in configuration possibly password DATA to V3 0207 Only Administrator later than...

Page 122: ...paces or commas To operate the outputs manually this function must be enabled see ADMIN SET PERMIT Whether with or without output switch the DATA command always returns the current states of the outputs e g DATA O1 on O2 off o3 1 o4 0 leads to output DATA Reinhardt MWS OUTPUT 1 ON OUTPUT 2 OFF OUTPUT 3 ON OUTPUT 4 OFF OUTPUT 5 OFF Heating_1 OFF Heating_2 OFF Fan ON With defined or in sensor output...

Page 123: ...reviously set with ADMIN STATION STATION IDENT 255 BAUD 9600 NAME Reinhardt MWS ADMIN STATION SENSOR x NUMBER s ADMIN STATION SENSOR x NUMBER s Define sensor position x 1 32 with sensor s s Sensor see Sensors overview ADMIN STATION SENSOR x IDENT cccc ADMIN STATION SENSOR x IDENT cccc cccc Prefix maximum four characters from the following selection set in front of the measured value in the output ...

Page 124: ...ephone number sets the current telephone number from which the command was sent as Administrator number If the command is sent via the serial interface the telephone number must be attached in inter national format 49 The administrator number enables a mobile phone to pass all ADMIN commands without the IMEI number as a password However an administrator password set with ADMIN SET PASSWORD always ...

Page 125: ...ts with 192 168 10 24 bits for the compare mask The use of a single IP address is of course possible although not so save as well as the entry of address ranges ADMIN SET ADDRESS 192 168 10 25 for example only allows one IP address while ADMIN SET ADDRESS 192 168 x or ADMIN SET ADDRESS 192 168 0 0 16 allows all IP addresses as administrators starting with 192 168 The same can be done with the MAC ...

Page 126: ...tterymode powersup5minutesbeforethefull hour and turns off 10 minutes later Caution Data is not logged in the meantime A combined operation with value 10 is also possible In the diagram illustrated the storage interval is orange and the operating times of the station are shown in green 10 SHUTDOWN_LOGGING_ACCU Priority 2 Ifthestationisswitchedoffinstandardandinbatterymode itwillbootup30seconds bef...

Page 127: ...ithin a second again ADMINSETOUTPUTxTERM hour Term1 Link T 2 V T 3 V Term4 ADMIN SET OUTPUT x TERM hour Term1 Link T 2 V T 3 V Te rm4 The command ADMIN STATION OUTPUT x TERM is used to establish an automatic switching of the output x 1 8 depending on up to 4 sensors With hour you can select the period in which the automatic switching is active It can be se parated by a comma for several hours or t...

Page 128: ...10 C and the wind speed is higher than 10 km h Output 1 is switched off if in 3 successive data strings either temperature is no longer below 10 C or the wind speed drops below 10 km h This avoids that short peaks switch the output ADMIN SET OUTPUT 4 TERM 3 wg 10 wr 25 335 checks permanently and switches output 4 on if in 3 successive data strings the wind speed is higher than 10 km h an the wind ...

Page 129: ... the voltage is sufficient and if successful switched on again The station will be reactivated immediately if it is supplied either via the voltage connector serial interface via USB or via PoE If the voltage falls below level 2 it is assumed that battery operation is in progress and various energy saving measures selected with ADMIN SET POWER can be initiated An optional handset can be switched o...

Page 130: ...the following values may be inserted 17 19 Reserved 16 ETHERNET_ENABLE Enables the Ethernet port 15 USB_ENABLE Enables the USB port 14 ADMIN_ONLY Changing settings may ONLY be done from the administrator s address number even if e g in Ethernet the privileged authorization is set 12 13 Reserved 11 DIGDATA Allows manual modification of the digital outputs via DATA 1 10 Reserved ADMIN GET PERMIT ADM...

Page 131: ...irectory ADMIN LOAD CONFIG ADMIN LOAD CONFIG Loads the file _system save config sav and transferres the containing information into the flash memory This takes about 20 minutes If the command was sent via the serial interface a progress bar is transmitted LOAD CONFIG I Each minus sign corresponds to 1 each plus sign to 10 and the I to 50 ATTENTION If the flash memory is write protected ADMIN LOCK ...

Page 132: ...uest outputs LEVEL Request voltage limits PERMIT Request creation and message restrictions STATION Request station s parameters name baud rate SENSOR Request sensor s parameters identifier name unit ERR Request error list INCLUDE Request all access addresses EXCLUDE Ausgabe aller zehn Rufnummern die abgewiesen werden ETHERNET Request IP router name server adsresses CONNECTIONS Request all current ...

Page 133: ...nd Sensors 55 geändert am 04 12 2020 von DO REINHARDT System und Messelectronic GmbH Fax 08196 7005 and 1414 email wetter reinhardt testsystem de Web http www reinhardt wetterstationen de to table of contents This page is left free for further expansions ...

Page 134: ...ng MWS4 MWS 5M V MWS6 Sensors with logger Click on picture to enlarge Step 1 Check packing on damage Take out the complete inner package carefully Click on picture to enlarge Step 2 Take out the socket with the weather station from the package Click on picture to enlarge Step 3 Take out the weather station from the socket carefully Keep the packing Click on picture to enlarge Step 4 Mount the weat...

Page 135: ... enlarge Step 6 Take off the 3 lower elements of the protection against radiated heat Click on picture to enlarge Step 7 Lead the cable through the protection against radiated heat Click on picture to enlarge Step 8 Connect the cable to the POWER socket and fix it Click on picture to enlarge Step 9 Remount the protection against radiated heat The hardware now is installed Click on picture to enlar...

Page 136: ...when the cable is laid in the pipe Click on picture to enlarge Step 1 Check packing on damage Take out the complete inner package carefully Click on picture to enlarge Step 2 Take out the socket with the weather station from the package Click on picture to enlarge Step 3 Take out the weather station from the socket carefully Keep the packing Click on picture to enlarge Step 4 Draw the cable throug...

Page 137: ...cture to enlarge Step 6 Connect the cable to the POWER socket and fix it Lead the cable near the fan without jamming the fanwheel Mount the weather station onto a 1 pipe Click on the picture to enlarge Step 7 Move up the 3 lower elements of the protection against radiated heat Click on the picture to enlarge Step 8 Remount the 3 lower elements of the protection against radiated heat Click on the p...

Page 138: ... it and take out the top board and the cable Click on the picture to enlarge Step 2 Take out the MWS 9 5 carefully Particularly take care of the windsensors Click on the picture to enlarge Step 3 Mount a 1 pipe at the desired location of the MWS 9 5 The pipe is not in the scope of delivery Pay attention to proper mounting of the pipe Click on the picture to enlarge Step 4 Lay the cable to the loca...

Page 139: ...socket properly Click on the picture to enlarge Step 7 Connect the cable to the power port of the MWS 9 5 and tighten it The MWS 9 5 now is ready for operation CAUTION Only plug in the cable when the PSU is already connected to the mains Otherways the MWS 9 5 is running only with the internal batteries and discharges them within 1 hour Click on the picture to enlarge Step 8 Start the software to i...

Page 140: ...Packing MWS 55 properly In case you want to ship your MWS 55 you must use the original packing This packing was especially designed for MWS 55 It is the best protection against damage or de struction during transport In this packing it will not even be damaged if it falls from 1 m height onto a concrete floor Do not fill the packing with polystyrene flakes They could damage the wind vanes when the...

Page 141: ...ontents I OE Specifications subject to change without prior notice 12 20 11 Exchange Connectors In case you have to replace connectors please contact Fa Adam Tel 49 0 8131 2808 51 The connectors belong to Series 711 Below you will find the order numbers 5way connector heating GPS 99 0095 102 05 7way connector data and power supply 99 0475 102 07 8way connector additional sensors 99 0479 102 08 Of ...

Reviews: