background image

VEGA 390

THERMAL STORE

with stainless steel DHW coil

EN

v. 1.3

Installation and Operation Instructions

Summary of Contents for VEGA 390

Page 1: ...VEGA 390 THERMAL STORE with stainless steel DHW coil EN v 1 3 Installation and Operation Instructions...

Page 2: ...5 5 1 Mounting pump stations and accessories onto VEGA 390 6 5 2 Connecting heating circuits 17 5 3 Connecting a solar circuit 17 6 Installation and Commissioning 18 6 1 Connecting heat sources 18 6...

Page 3: ...tly on the tank the second main layer features thermal conductivity l 0 032 W m K the third layer is a hard glossy washable surface The total insulation thickness is 100 mm 1 4 Connection points 1 top...

Page 4: ...changer volume 23 l DHW heat exchanger surface area 6 sqm Max working temperature in tank 95 C Max working temperature in DHW heat exchanger 95 C Max working pressure in tank 4 bar Max working pressur...

Page 5: ...he tank The heat exchanger connects to a cold water inlet with a G1 nipple and to DHW with the other one As soon as hot water is drawn from an outlet cold water flows into the immersed heat ex changer...

Page 6: ...1 2 stainless steel 3 pcs 12714 Cover for 2 circuit pump station for 380l Thermal Store 1 pcs 12223 Front insulation for cover for 2 circuit pump station 1 pcs 12721 Top insulation for 2 circuit pump...

Page 7: ...ealant or with the gaskets included in separate kits 1 Remove the tank from its pallet and place it to its approximate position shift the bottom insulation under the tank 2 Slide the insulation insert...

Page 8: ...76 Remove the zone valve actuator from the assembly prior to mounting Port A of the zone valve shall be oriented upwards 6 Loosen the clamps fit the metal sheet against the four pins code 12710 from K...

Page 9: ...690 8 Fit the pump station with 4 way mixing valves code 12224 or 12225 Join it with the earlier fitted Angled Ball Valve Assy and tighten the clamps 9 Fit 1 Valve Assy out to h circuit code 13479 and...

Page 10: ...Assy out to h circuit code 13497 11 Fit the Safety Drain Valve Assy code 13529 into the sleeve 12 Fit the sheaths code 154 into the dedicated sleeves and plug 1 2 with gasket code 9097 Plug 1 2 code...

Page 11: ...11 13 Fit the Zone Valve Assy out to HP code 13477 Remove the zone valve actuator prior to fitting Port A of the zone valve shall be oriented upwards 14 Fit the 1 Elbow Assy out to HP code 13494...

Page 12: ...12 15 Fit the thermometer code 10474 from the Kit 13237 16 Fit the 1 Elbow Assy in from HP code 13478...

Page 13: ...sulation circa 550 mm long 1 tube 5 4 DN 25 125 mm long code 13484 insulation circa 200 mm long 18 Locate the Zone Valve Assy fitted as shown in point 13 and the Elbow Assy fitted as shown in point 14...

Page 14: ...fitted as shown in point 11 Connect these two using the dedicated 1 pipe 690 mm long code 13489 21 Locate the 1 hex nipple in the Zone Valve Assy fitted as shown in point 13 and the 1 Elbow Assy fitte...

Page 15: ...code 6971 all included in Kit 13237 23 Push the front insulation onto the pump station with 4 way valves 24 Connect the terminals of the pumps push the cables behind the insulation 25 Fit the plastic...

Page 16: ...16 Completely fitted tank Safety high limit thermostat for electric heating elements optional part...

Page 17: ...o connected to a solar thermal system An extra flange and a tube heat exchanger coil will be needed depending on the output of the solar thermal system All connecting pipes between the tank and solar...

Page 18: ...ating elements shall be installed together with a safety temperature limiter An el heating element shall be wired by qualified staff only 6 4 Connecting sanitary water piping DHW piping shall be done...

Page 19: ...Installation Manual was not respected the product was used for other purposes than intended Warranty does not cover usual wear and tear damage caused by fire water electricity or a natural disaster de...

Page 20: ...04 2016 REGULUS spol s r o Do Kout 1897 3 http www regulus eu 143 00 Praha 4 E mail sales regulus eu CZECH REPUBLIC...