REGENCY FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

919-470e

06.13.17

Panorama

®

 P36E  Zero  Clearance

Direct  Vent  Gas  Fireplace

Owners & Installation Manua

l

Tested by:

Installer

: Please complete the details on the back cover 

and leave this manual with the homeowner.

Homeowner:

 Please keep these instructions for future reference.

MODELS:    P36E-NG10 Natural Gas     P36E-LP10  Propane

 

-  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance. 

- WHAT TO DO IF YOU SMELL GAS

 • 

Do not try to light any appliance.

 

•  Do not touch any electrical switch: do not use any phone in your building.

 

  Leave the building immediately.

 

•  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's 

 

instructions.

 

• If you cannot reach you gas supplier, call the fire department.

 

 

 

- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

     WARNING

FIRE OR EXPLOSION HAZARD

F

ailure to follow safety warnings exactly could result in serious

injury, death, or property damage.

 

Summary of Contents for P36E-LP10

Page 1: ...r flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach you gas supplier call the fire depart...

Page 2: ...d to provide you with all the warmth and charm of a wood fireplace at the flick of a switch The model P36E has been approved by Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Reg...

Page 3: ...ons and local codes if any In the absence of local codes follow the current National Fuel Gas Code ANSI Z223 1 and the current National Electrical Code ANSI NFPA 70 in the U S A and the current CAN CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22 1 in Canada This Regency Mobile Manufactured Home Listed appliance comes factory equipped with a means to secure the unit ...

Page 4: ...ct Vent System Flex Installation Procedures 32 Vertical Termination 4 x6 5 8 Venting 33 Flex vent components 34 Gas Line Installation 35 Pilot Adjustment 36 885 S I T Valve Description 36 Gas Pipe Pressure Testing 36 High Elevation 36 Conversion from NG to LP 37 Optional Brick Panels 38 Log Set Installation 39 Standard Flush Door 42 Vignette faceplate and safety screen installation 43 Vignette fin...

Page 5: ... Part 919 469a Colour Everything black on grey except what is highlighted is printed red Material 2 ml silver matt polyester DPM SMS Size 100 Oct 23 2014 Created decal Apr 27 15 Rev A Added screen part Printer Continue number sequence from 918 853 do not restart at 0 This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 or Natu...

Page 6: ...tly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspecti...

Page 7: ...NIT DIMENSIONS WITH VIGNETTE AND VIGNETTE FINISHING TRIM 37 1 2 32 5 8 31 3 8 12 3 4 14 3 4 2 953mm 324mm 375mm 829mm 797mm 1 1 4 26mm Optional 3 sided finishing trim not shown 38 W x 33 3 4 H ALL PICTURES DIAGRAMS SHOWN THROUGHOUT THIS MANUAL ARE FOR ILLUSTRATION PURPOSES ONLY ACTUAL PRODUCT MAY VARY DUE TO PRODUCT ENHANCEMENTS ...

Page 8: ...and any repairs to this appliance should be done by a qualified service person A professional service person should be called to inspect this appliance annually Make it a practice to have all of your gas appliances checked annually 13 Do not slam shut or strike the glass door 14 Under no circumstances should any solid fuels wood paper cardboard coal etc be used in this appliance 15 The appliance a...

Page 9: ... Ensure that structural members are not cut or weakened during installation 2 Ensure proper grounding using the 8 ground lugprovided Seethe AlternateWiringDiagram for Wall Switch section 5 ThisapplianceisListedforbedroom installations when used with a Listed Millivolt Thermostat Some areas may have further requirements check local codes before installation 6 The P36E Direct Vent Gas Fireplace is a...

Page 10: ...st be maintained from the top surface of the carpeting tile etc Minimum Clearance from Top of Unit to Ceiling from top of unit 32 1016mm Side Wall Clearances 6 152mm Measured from edge of unit See the Regency Clearances for dimensions section Horizontal Vent Clearances Top 2 51mm Side 1 1 2 38mm Bottom 1 1 2 38mm Vertical Vent Clearances 1 1 4 32mm Alcove Clearances Max Depth 36 914mm Min Width 48...

Page 11: ...Fireplace 11 11 installation Min 6 152mm 30 1 2 775mm Top of Unit Min 32 1016mm to Ceiling CLEARANCES MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram Maximum 1 1 2 projection at 2 minimum clearance Unit width 36 1 6 E ...

Page 12: ...ishing below the mantel and the width of the Vignette finishing trim 37 1 2 must be non combustible if a lower mantel is desired Note Ensure the paint that is used on the mantel and the facing is heat resistant or the paint may discolour MANTEL CLEARANCES WITH VIGNETTE VIGNETTE FINISHING TRIM STEPPED FINISH MANTEL CLEARANCES WITH VIGNETTE VIGNETTE FINISHING TRIM FLUSH FINISH MANTEL CLEARANCES WITH...

Page 13: ...ee as the rest of the house apply vapour barrier and drywall as per local instal lation codes Do not insulate the fireplace itself 4 The top of the unit must not be closer than 32 813mm to the ceiling 3 8 1 3 82 mm 2 37 7 16 951mm Non combustible Material supplied Steel stud on edge 2nd Steel stud on edge install after unit in place 12 305mm Wood stud Wood stud Drywall Diagram 4 Diagram 5 Vignette...

Page 14: ...ghttocombustiblematerials includingtheMinimum2 51mm Topclearance to the Horizontal Vent Diagram 1 Diagram 3 Diagram 5 Diagram 6 Diagram 2 Diagram 4 B Steel stud on edge A C D Minimum Height to Combustible Material B Steel stud on edge A C D Minimum Height to Combustible Material Frame in the enclosure for the unit with framing material The framed opening is 36 1 4 high x 36 1 4 wide x 12 3 4 deep ...

Page 15: ...nette faceplate if not using the optional finishing trim To maintain a clean finished edge it is recommended to install the combustible facing material with the finished edge against the fireplace nailing strips Alternatively you can use J Style Trim or Metal Corner Bead to cover cut edges of the non combustible facing material 38 33 3 4 Diagram 1 Note 40 1 2 1029mm is the minimum height for both ...

Page 16: ... junction box to the framing at desired location within 10 ft from fireplace 2 Feed the 12 pin connector through the opening at back of junction box 3 Connect the 12 pin connector to the back of the receiver 4 Install the Receiver in the Low Voltage Junction box 5 Insert the 4 AA type batteries in the battery compartment with the correct polarity 6 Place the slider into the cover plate 7 Put the R...

Page 17: ...The gas appliance and vent system must be vented directly to the outside of the building and never be attached to a chimney serving a separate solid fuel or gas burning appliance Eachdirectventgasappliancemustuseit sown separate vent system Common vent systems are prohibited NAILING STRIPS Determine the total thickness of facing material e g noncombustibleplusceramictiles toallow the finished surf...

Page 18: ...e extended above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on p...

Page 19: ... run of 4 feet 1 6 7 8 dia flexible liner 4 ft length 2 4 dia flexible liner 4 ft length 3 spring spacers 4 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 screws 8 x 1 1 2 Drill Point Stainless Steel 4 1 6 7 8 dia flexible liner 10 ft length 2 4 dia flexible liner 10 ft length 3 spring spacers 7 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7 t...

Page 20: ...able Length 7 Galvanized N A N A 4D7A N A N A N A N A Adjustable Length 7 Black N A N A 4D7AB N A N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI N A Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 TC 4dLSIB N A Extension Pipe 16 Galva...

Page 21: ... A N A N A N A TM 4ST14 N A Snorkel Termination 36 N A N A N A N A N A TM 4ST36 N A Basic Horizontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK TM4 HTK VDV KW04 Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK TM4 HTK VDV K04 Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHTK SV FK N A N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Sid...

Page 22: ...es Vent Length Required inches 3 1 4 6 3 4 11 14 5 8 Adj Pipe 7 3 4 16 1 4 17 24 Adj Pipe 7 1 4 8 3 4 6 12 9 9 4 1 4 5 3 4 6 9 Rigid Pipe Adaptor Pipe Length Vertical Termination Cap Storm Collar Flashing Ceiling Firestop 24 Pipe Length Adj Pipe Length 11 14 5 8 90 Elbow o Horizontal Termination Cap Wall Thimble Vinyl Siding Standoff Optional Alternate Horizontal Ter mination Caps Must be used wit...

Page 23: ...ipe adaptor Part 510 994 when using Rigid Pipe venting systems All Rigid Pipe Systems 4 inner diameter 6 5 8 outer diameter Regency Flex Vent 4 inner diameter 6 7 8 inner diameter Maintain clearances to combustibles Horizontal vent must be supported every 3 feet Firestops are required at each floor level and whenever passing through a wall A vent guard should be used whenever the termination is lo...

Page 24: ...0o elbows is required A 0 Min 2 Max B 1 Min 3 Max C 2 Min 4 Max D 3 Min 5 Max E 4 Min 6 Max F 5 Min 7 Max G 6 Min 8 Max Lengths do not include elbow indicated Option V H V V1 H H1 With these options max total pipe lengthis30feetwith min of 12 feet total vertical and max 9 feet total horizontal Please note min 1 foot between 90o elbows is required A 0 Min 1 Max 1 Min 2 Max B 1 Min 2 Max 3 Min 3 Max...

Page 25: ... Min 2 Max 1 Min B 1 Min 4 Max 2 Min C 2 Min 5 Max 3 Min D 3 Min 6 Max 4 Min E 4 Min 7 Max 5 Min F 5 Min 8 Max 6 Min Lengths do not include elbow indicated For additional vertical venting with 2 x 90o elbows refer to next page Option V H H1 V V1 With these options max totalpipelength is 30 feet with min of 10 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o el...

Page 26: ...clearances to combustibles Note Must use optional rigid pipe adaptor when using rigid vent systems Part 510 994 RIGID PIPE VENTING ARRANGEMENTS VERTICAL TERMINATIONS Propane Natural Gas The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations using two 90o elbow with Rigid Pipe vent systems for Propane and Natural Gas ...

Page 27: ...Gas as per the diagram 1 The shaded area in the diagram 1 shows all allowable combinations of straight vertical and offset to vertical terminations with rigid pipe vent systems for Propane and Natural Gas Maximum two 45o elbows allowed Vent must be supported at offsets Firestops are required at each floor level and whenever passing through a wall Maintain clearances to combustibles ...

Page 28: ...g Arrangements section for minimum and maximum heights Masonry chimneys may take various contours which the flexible liner will accommodate However keep the flexible liner as straight as possible avoid unnecessary bending The Air Intake pipe must be attached to the inlet air collar of the termination cap Required Parts Part Description 946 529 Co linear DV Vertical Termination Cap 948 305 3 Flex 3...

Page 29: ...haded area in the diagrams show the allowable vertical terminations 8 Min 40 1 2 30 Max 30 Horizontal Distance Feet Vertical Height feet 2 max VENTING ARRANGEMENTS VERTICAL TERMINATION with Co linear Flex System for both Residential Manufactured Homes into Masonry Fireplaces ...

Page 30: ...our indenta tions located on the female ends of pipes and fittings are designed to slide straight onto the male ends of adjacent pipes and fittings by orienting the four pipe indentations so they match and slideintothefourentryslotsonthemale ends Diagram1 Pushthepipesections completely together then twist lock one section clockwise approximately one quarter turn until the two sections arefullylock...

Page 31: ...sembly It is important that the vent pipe extends into the vent cap sufficient distance so as to result in a minimum pipe overlap of 1 1 4 inches Secure the connection between the vent pipe and the vent cap by attaching the two sheet metal strips extending from the vent cap assembly into the outer wall of the vent pipe Use the two sheet metal screws provided to connect the strips to the pipe secti...

Page 32: ...pf eps french Offset Chart DIRECT VENT SYSTEM FLEX INSTALLATIONPROCEDURES 1 Locate the unit in the framing rough in the gas preferably on the right side of the unit and the electrical Junction block is on the left side on the left Locate the centerline of the termination and mark wall accordingly Cut a 10 254mm hole in the wall inside dimension Note A2 clearance at the top and 1 1 2 clear ancearou...

Page 33: ...8 VENTING VERTICAL FLEX VENT KIT 946 755 11 Secure inner flex pipe to pipe adaptor by using Mill Pac over the adaptor Slide the inner pipe over adaptor and secure with 3 screws 12 Repeat Step 11 to secure outer flex Diagram 4 14 Put a bead of caulking on the exterior between the outer pipe and flashing to prevent water from penetrating the chimney system 15 Slide storm collar over pipe length unti...

Page 34: ... pipe 20ft 10 spring spacers 1 919 698 919 698 08 10 16 08 10 16 60 1 4 Ceiling firestop 60 1 4 Ceiling firestop Diagram 1 Diagram 1 Diagram 1a Diagram 1a Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Firestop spacer to prevent debris from falling into the c...

Page 35: ...or servicing Flare nuts for copper lines and flex connectors are usually considered to meet this requirement Important Always check for gas leaks with a soap and water solution or gas leak detector Do not use open flame for leak testing P36E NG10 System Data For 0 to 4500 feet altitude Burner Inlet Orifice Sizes 37 Max Input Rating 29 500 Btu h M i n Input Rating 19 500 Btu h Supply Pressure min 5...

Page 36: ... pressure check should be carried out with theunitburningandthesettingshouldbewithin the limits specified on the safety label 6 When finished reading manometer turn off the gas valve disconnect the hose and tighten the screw clockwise with a 1 8 flat screwdriver Note Screwshouldbesnug butdonotover tighten HIGH ELEVATION This unit is approved in Canada for altitude to 4500ft CAN CGA 2 17 M91 ForNat...

Page 37: ...with the allen key then replace with the LP pilot orifice and the pilot cap provided in the kit 7 Remove burner orifice with a 1 2 wrench Use another wrench to hold on to the elbow behind the orifice Discard orifice Burner Orifice Remove the 2 screws push Burner Assembly to the left and lift out 3 Remove the 2 screws holding the Burner Assembly to the firebox base Push the Burner Assembly to the l...

Page 38: ...logs must not be in the unit 3 Insert the back brick panel first by carefully slipping it between the back wall of the firebox and the rear log bracket 4 Put the side panels in next Slide them in from the front and push them flat up against the wall Be very careful not to scratch them on the firebox hardware 5 Install the 2 brick retaining clips one on each side OPTIONAL BRICK PANELS ...

Page 39: ...og h 902 156 Embers i 902 179 21 Vermiculite j 946 669 Platinum Embers supplied w packaged manual 4 Place Log 02 51 on the front right side of the burner Push the back of the log against the 2 brackets with the notch on the bottom right side of the log fitting into the right side of the grate Notch Bracket Bracket 3 Place Log 02 49 on the rear log support pins with the flat side to the back 02 49 ...

Page 40: ... of the log against the 2 front brackets with the notch on the bottom of the log fitting into the first grate tab Notch 02 55 02 50 02 54 5 Position Log 02 53 across the cutouts in Logs 02 49 and 02 51 with the notch on the left side of the log fitting into the 2nd grate tab Cutouts 2nd Grate Tab 02 53 02 49 02 51 02 49 02 51 02 53 02 49 02 51 02 53 02 55 02 53 02 50 02 55 02 53 02 50 02 55 02 53 ...

Page 41: ...tween Logs 02 51 and 02 49 and on the indentation on Log 02 54 The bottom right end sits behind the rear grate tab 10 Place the embers on the front of the burner tray in the places shown on the photo Separateplatinumembersandplaceonthefrontburneron and around the embers Avoid stacking platinum embers Platinum embers may be placed over burner ports 11 Test fire to ensure proper light off make sure ...

Page 42: ...o the installation of the Vignette faceplate The standard flush door comes with a black frame To install the frame simply hook the top door flange onto the top of the unit and swing the door towards the unit see Diagram 1 Be careful that the glass gasket does not roll up there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit see Diagram 2 Diagram ...

Page 43: ...he P36 P36E units and the outer slots for the P36D P36D P36 P36E Tab Slot 2 Slot the tabs on the inner Vignette frame with safety screen into the corresponding slots in the outer Vignette frame as shown below Adjustable Mounting Brackets are in increments of 1 8th P36 ONLY 3 Check to ensure that the vignette frame and screen are evenly spaced at top and bottom looking from side If it is not evenly...

Page 44: ...side 2 Secure with 2 screws each side 3 Loosen the 3 screws in the top inside edge of the firebox 4 Slide the Finishing Trim Top over the Side Trim pieces and fit the bottom bracket slots over the screws Tighten the 3 screws to secure 5 Hook Vignette Faceplate brackets into place 7 Hook Vignette Faceplate brackets into place see specific instruc tions in unit manual 6 Install the lower finishing t...

Page 45: ...3 Position the Inlay so it is exactly centered from side to side and top to bottom within the Inner Vignette Frame 4 With the top of the Inlay in correct position push the studs at the bottom of the Inlay through the actual screen NOTE Ensure Inlay is in correct position before pushing studs through the safety screen 5 Secure the Inlay in position with supplied brackets washers and nuts as shown B...

Page 46: ...de trim with the holes in the firebox side 2 Secure with one screw per side on top the bottom screw is installed after the Vignette faceplate bracket is in place P33 P33E only 3 Loosen the 3 screws in the top inside edge of the firebox 4 Slide the Finishing Trim Top over the Side Trim pieces and fit the bottom bracket slots over the screws Tighten the 3 screws to secure 5 Hook Vignette Faceplate b...

Page 47: ...558a 919 558a 07 21 15 07 21 15 SAFETY SCREEN INSTALLATION MUST BE USED WITH OPTIONAL LOUVERS 1 Hook the safety screen frame over the glass door frame 2 Gently lower screen on to glass door frame two 2 magnets located on inside lower part of the screen frame will secure the screen to the glass door frame 3 To remove reverse steps Magnet locations SAFETY SCREEN INSTALLATION MUST BE USED WITH OPTION...

Page 48: ...mend removing the 4 AA batteries in the SureFire receiver This will avoid battery leakage and power drainage 4 AA Battery pack may be re installed into receiver during power outages 919 063 10 09 14 1 Plug AC adaptor into a 120V wall outlet or into the 120V receptacle if installed inside the gas fireplace 2 Tuck any loose wires neatly underneath the firebox inside the fireplace Note Ensure that wi...

Page 49: ... not require a 120V A C supply for operation but it is highly recommended to install the supplied AC adaptor to eliminate the need for batteries In case of a power failure the burner switch and the optional remote control will continue to operate if batteries are installed in the receiver However a 120V A C power supply is needed for the fan blower operation Do not cut the ground terminal off unde...

Page 50: ...lation WIRING DIAGRAM WITH OPTIONAL FAN SureFire Switch CAUTION Labelallwirespriortodisconnection whenservicingcontrols Wiringerrorscancause improper and dangerous operation Caution Ensure that the wires do not touch any hot surfaces and are away from sharp edges ...

Page 51: ...to wiring diagram 5 Slide the thermodisc cover assembly on to the bracket clip on the underside of the firebox Thermodisc Clip 6 Install the Fan Control Module FCM on the base of the unit to the left of the gas valve Plug the FCM into the outlet 7 Plug in the fan power cord to the Fan Control Module into the outlet marked Fan Plug the FCM COM wire from the remote control wiring harness into the lo...

Page 52: ...ed TH at the white connector shown below The noted wires will be located near the gas valve Disconnect greenTH wire Green Wires White Connector 3 Connect one thermostat lead to female connector using male spade connector see picture below CAUTION Do not wire Thermostat wires to 120V wire 4 Connect the other thermostat lead to male connector disconnected from Step1using a female spade connector see...

Page 53: ...vent possible shock 3 Check to ensure there are no gas leaks 4 Make sure the glass in the door frame is properly positioned Never operate the appliance with the glass removed 5 Verify that the venting and cap are unobstructed 6 Ensure that the brick panels are installed 7 Verify log placement If the pilot cannot be seen when lighting the unit the logs have been incorrectly positioned 8 The unit sh...

Page 54: ...60 seconds If there is no flame ignition rectification the board will stop sparking for approximately 35 seconds After wait time the board will start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will need to be reset as follows a Turn the system off using ON OFF switch or press ON OFF button if us...

Page 55: ...taller service agency or gas supplier AVERTISSEMENT Quiconque ne respecte pas à la lettre les instructions dans la présente notice risquede déclencher un incendie ou une explosion entraînant des dommages des blessures ou la mort Une installation d ajustement de modification de service ou d entretien peut provoquer des blessures ou des dommages matériels Reportez vous au manuel du propriétaire de l...

Page 56: ...dencesofexcessivecondensation such as water droplets forming in the inner liner and subsequently dripping out the joints Continuous condensation can cause corrosion of caps pipe and fittings It may be caused by having excessive lateral runs too many elbows and exterior portions of the system being exposed to cold weather LOG REPLACEMENT The unit should never be used with broken logs Turn off the g...

Page 57: ... instructions in manual 3 Remove the logs 4 Remove the burner grate assembly by removing the two screws and then lift the burner assembly out Diagram 1 Remove the left and right screws and then lift out the burner grate assembly 9 Remove the rear log stand by removing the 2 screws 10 Remove the 10 screws securing the valve tray assembly in place Diagram 2 and then lift the entire assembly out Diag...

Page 58: ...Brick Panel Set Standard Red 513 903 Brick Panel Set Herringbone Brown 33 Brick Panel Back 34 Brick Panel Left 35 Brick Panel Right 511 031 Brick Clips each Part Description Burner 438 917 Fan Assembly 120V 42 910 331 P Fan Motor 120 V 50 510 994 Rigid Pipe Adaptor 946 556 Heat Wave Duct Kit Optional 89 946 004 Junction Box 90 946 000 Round Duct Adaptor 91 946 002 Round to Oval Adaptor 92 946 001 ...

Page 59: ...P36E 10 Zero Clearance Direct Vent Gas Fireplace 59 59 parts list ...

Page 60: ...04 390 Orifice 52 Propane 936 170 Orifice Gasket 910 100 Pilot Orifice NG 910 101 Pilot Orifice LP 79 514 535 Burner Assy 82 511 030 Burner Grate Assy 83 430 101 Rear Log Support Bracket 84 Deflector 85 512 930 Log Set 911 037 Flame sense 911 038 Flame electrode 910 432 Pilot tube 910 096 Two Way Pilot Hood 911 137 Pilot Hood Clip 911 012 Ignition Board DFC 911 013 Valve Wiring Harness 911 032 Rem...

Page 61: ...n 1 515 922 Vignette Platinum 515 923 Vignette Black Chrome 515 924 Vignette Black 515 926 Vignette Tuscan Sunset 2 515 918 Vignette Door Inlay Black Chrome 515 919 Vignette Door Inlay Metallic Black 515 920 Vignette Door Inlay Tuscan Sunset 515 922 Vignette Front Platinum 515 928 Vignette Finishing Trim w NCB Not Shown ...

Page 62: ...10 Zero Clearance Direct Vent Gas Fireplace 62 parts list Part Description 3 515 986 3 Sided Finishing Trim 510 922 Flush louvers black 515 929 Safety Screen 948 223 Regency Logo Plate SAFETY SCREEN AND LOUVERS ...

Page 63: ...P36E 10 Zero Clearance Direct Vent Gas Fireplace 63 63 notes ...

Page 64: ...dule Battery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwis...

Page 65: ...ages downdrafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction...

Page 66: ...nal legal codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief description of the problem and your address email ...

Page 67: ... below in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purch...

Page 68: ......

Page 69: ...P36E 10 Zero Clearance Direct Vent Gas Fireplace 69 69 notes ...

Page 70: ...70 P36E 10 Zero Clearance Direct Vent Gas Fireplace 70 notes ...

Page 71: ......

Page 72: ...nformation Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No __________________________________...