This instruction sheet provides you with the information required 

to safely own and operate your product. Retain these instructions 

for future reference.
The product you have purchased is of the highest quality  

workmanship and material, and has been engineered to give you 

long and reliable service. This product has been carefully tested, 

inspected, and packaged to ensure safe delivery and operation. 

Please examine your item(s) carefully to ensure that no damage 

occurred during shipment. If damage has occurred, please con-

tact the place of purchase. They will assist you in replacement or 

repair, if required.

READ THESE INSTRUCTIONS CAREFULLY BEFORE 

ATTEMPTING TO INSTALL, OPERATE, OR SERVICE 

YOUR PRODUCT. KNOW THE PRODUCT’S APPLICATION, 

LIMITATIONS, AND POTENTIAL HAZARDS. PROTECT 

YOURSELF AND OTHERS BY OBSERVING ALL SAFETY 

INFORMATION. FAILURE TO COMPLY WITH THESE 

INSTRUCTIONS COULD RESULT IN PERSONAL INJURY 

AND/OR PROPERTY DAMAGE!

DESCRIPTION

This unit is designed to pump wastewater from laundry trays, 

washing machines, sinks, or dehumidifiers. It is not designed to 

pump raw sewage, fluids other than water, or fluids with solids. 

Inlet screen will remove many solids over 1/8” diameter, but large 

amounts of solids can clog screen and result in pump failure. 

Maximum fluid temperature is 125°F. Unit is designed to fit under 

most sinks, so in many cases it is not necessary to recess the 

unit into the floor.

ITEMS TO PURCHASE

NOTE:

 Some state or local codes require all electrical and/or 

plumbing connections to be made by a licensed contractor. It is 

the customer’s responsibility to determine codes involved and 

to comply with these codes. If user can install unit, items to 

purchase are:

  1.  Inlet piping, trap and union. (Basin cover has 1-1/2” FNPT fitting.)
  2.  Discharge piping with union. (Basin cover has 1-1/2” FNPT fitting.)
  3.  Vent piping with union. (Basin cover has 1-1/2” FNPT fitting.)

SAFETY GUIDELINES

 1. 

CAUTION:

 To reduce the risk of electric shock, pull plug 

before servicing this pump.

  2. Read all instructions and safety guidelines thoroughly. Failure 

to follow the guidelines and the instructions could result in 

serious bodily injury and/or property damage.

  3. Check local electrical and building codes before installation. 

The installation must be in accordance with these regulations.

  4. During normal operation the pump is immersed in water. Use 

caution to prevent bodily injury when working near the pump:

  a. Remove plug from the receptacle prior to touching, servic-

ing, or repairing the pump.

  b. To minimize possible fatal electrical shock hazard, use 

extreme care when changing fuses. Do not stand in water 

while changing fuses or insert your finger into fuse socket.

ELECTRICAL CONNECTIONS

All wiring must meet local codes, and a licensed electrical 

contractor is recommended. The pump is supplied with a 3-prong 

vented plug. Plugs must be plugged into a grounded receptacle 

and vent tube must remain unobstructed for proper pump 

operation. Pump should be on a separate circuit with fuse or 

circuit breaker and ground fault circuit interrupter (GFCI). Be sure 

electrical supply matches pump nameplate data. Do not use 

extension cord. If installed in basement, plug connection should 

be 4’ or more above floor, especially if basement floods. Be sure 

electrical connections cannot be reached by rising water. Under 

no circumstances should outlet box or receptacle be located 

where it may become flooded or submerged by water.

INSTALLATION

All plumbing must meet local codes. A licensed plumbing  

contractor is recommended. All fixtures connected to the SPXS33 

Basin Kit must be vented according to state and local codes.
  1. Assemble basin/pump.

 2. 

Determine proper location for unit.

 Locate unit so that inlet 

is gravity-fed. Unit will not draw water up from a lower level. 

Position and level basin. Keep basin away from any item 

that could puncture basin. Position selected should be conve-

nient to inlet, discharge, and vent piping, and electrical supply.

 3. 

Plumb inlet.

 Using 1-1/2” threaded pipe, plumb inlet to basin 

cover fitting. Use a P-trap and a union next to the basin. Use 

PTFE tape and hand tighten only on plastic fittings. Do not 

reduce below 1-1/2” piping.

 4. 

Plumb discharge.

 Using 1-1/2” threaded pipe, plumb  

discharge to basin cover fitting. Use a swing check valve  

no more than 3” from top of basin cover and a union. 

    Be sure discharge piping is sealed with PTFE tape and that 

lift height of pump is not exceeded. 

 5. 

Plumb vent.

 Plumb vent using 2” threaded pipe to fitting in 

basin cover. Use pipe joint compound on threads and hand 

tighten only on plastic fittings. The basin must be vented in 

accordance with state and local codes. The vent is essential for 

proper switch operation and must not be omitted or restricted. 

 6. 

Test unit.

 Connect power cord to electrical supply as stated 

in ELECTRICAL CONNECTIONS section. Secure power cord 

to piping with ties or tape. Fill unit with water through inlet. 

Pump should turn on with 7”–10” of water in tank, and turn off 

when 1”–3” of water is left in tank.

MAINTENANCE

WARNING: 

Before performing any maintenance, shut off water 

inlet and disconnect power cord from supply outlet. Pump may 

become hot during operation. Allow pump to cool before servicing.

Basin Screen:

 Remove 4 1/4-20 screen cover plate screws, plastic 

cover plate, seal ring, and screen. Clean inlet screen using a mild 

detergent and water. Examine O-ring and if deformed, replace 

with new O-ring. See replacement parts table.

Basin:

 Sediment may build up in basin causing pump to operate 

improperly. Remove 10 1/4-20 screws from cover. Remove cord 

grommet and loosen cords to allow slack and then remove cover.
Remove pump and clean basin using a mild detergent and water. 

Reassemble in reverse order. Torque screws 18–20 in.-lbs.
If pump alignment plate is removed, it must be reinstalled per 

pump alignment diagram.

Pump:

 Sediment or lint can clog pump and cause improper 

operation. If necessary, remove pump and clean inlet screen, 

using a mild detergent and water and reinstall. Plastic pump base 

may also be removed to clean around impeller and inside base. 

Remove the six base screws and clean base using a mild deter-

gent and water. Do not remove impeller. When reinstalling base, 

be sure seal ring is seated properly in groove and torque screws 

to 10–15 in.-lbs. See pump manual for other information. For any 

other pump repair, return the pump to a Little Giant authorized 

service center.

1

RL-SPS33

Wastewater

Removal System  

with RL-SP33V Pump

P. O. Box 12010

Oklahoma City, OK 73157-2010

888.956.0000 • Fax: 405.228.1561

www.RedLionProducts.com

Summary of Contents for RL-SPS33

Page 1: ...sement plug connection should be 4 or more above floor especially if basement floods Be sure electrical connections cannot be reached by rising water Under no circumstances should outlet box or receptacle be located where it may become flooded or submerged by water INSTALLATION All plumbing must meet local codes A licensed plumbing contractor is recommended All fixtures connected to the SPXS33 Bas...

Page 2: ...e seal 2 Install check valve and discharge pipe into pump Use Teflon tape on the pipe threads Place pump in the basin and pull power cord through the power cord hole in the cover Allow approximately 12 of cord between pump and Power cord seal Slip power cord seal 1 866 1 866 2 906 2 906 1 1 2 FNPT THREADED SMOOTH NO THREADS POWER CORD HOLE EITHER HOLE CAN BE USED AS VENT OR DISCHARGE COVER TOP VIE...

Page 3: ...d maximums as set forth in the instructions Warranty will be VOID if any of the following conditions are found 1 Product is used for purposes other than those for which it was designed and manufactured 2 Product not installed in accordance with applicable codes ordinances and good trade practices 3 Product connected to voltage other than indicated on nameplate 4 Pump used to circulate anything oth...

Page 4: ...rts or repair please contact 1 888 956 0000 Pour l aide technique des parties ou la réparation entrez s il vous plaît en contact 1 888 956 0000 Para la ayuda técnica partes o la reparación por favor póngase en contacto 1 888 956 0000 www RedLionProducts com ...

Reviews: