RSA 32.25 - RAD - ING - MAN.UT - 1412.1 - DIGITECH TR - MIAH6 - E04

    

Technical specification 

RADIANT BRUCIATORI S.p.A.  

Montelabbate (PU) ITALY 

ENGLISH

 

User Manual  

for model 

RSA 32 /25 

 

Wall mounted storage combi boiler  

premix condensing boiler

 

 

 

 
 
 

 

 
 
 
 

Summary of Contents for RSA 32/25

Page 1: ...5 RAD ING MAN UT 1412 1 DIGITECH TR MIAH6 E04 Technical specification RADIANT BRUCIATORI S p A Montelabbate PU ITALY ENGLISH User Manual for model RSA 32 25 Wall mounted storage combi boiler premix co...

Page 2: ...arting up the boiler pagina 3 4 INFO Menu pagina 3 5 Boiler functioning modes pagina 4 6 Filling the system pagina 5 7 Diagnostics Error codes pagina 5 8 Switching OFF the boiler pagina 6 9 Frost Prot...

Page 3: ...not attempt to start it All maintenance and gas conversion operations MUST BE CARRIED OUT BY PROFESSIONALLY QUALIFIED PERSONNEL Should any part of the boiler freeze up do not attempt to light it unde...

Page 4: ...ERRORS 3 MODE SELECTION BUTTON SUMMER ONLY WINTER ONLY SUMMER WINTER OFF 4 RESET BUTTON ERROR RESET FLUE TEST FUNCTION ACTIVATION CHIMNEY SWEEPER KEEP IT PRESSED FOR 7 SECONDS 5 DOMESTIC HOT WATER TE...

Page 5: ...nce pressed the parameter number will appear on the left side of the display and the associated parameter value will appear on the centre of the display Use and buttons of Heating Temperature setting...

Page 6: ...ion to SUMMER WINTER mode press the MODE SELECTION button 3 fig 1 The boiler will work for both central heating D H W systems The SUMMER WINTER mode setting of the boiler is signalled by symbols lit c...

Page 7: ...he display disappears the boiler will restart automatically If the problem persists Call the Service Centre Code E02 Safety Thermostat tripped Press Reset button on the control panel to reset the erro...

Page 8: ...0 Electric power supply out of the operation range Call the Service Centre Code F08 Frost protection function central heating circuit ON Wait for the completion of the operation Code F09 Frost Protect...

Page 9: ...d immediately call the Service Centre 10 Maintenance In order to ensure that the boiler operates efficiently and safely it is recommended that the appliance is inspected by a suitably competent techni...

Page 10: ...THE COMPANY RESERVES THE RIGHT TO APPLY VARIATIONS WITHOUT PRIOR NOTIFICATION NEITHER WILL THE COMPANY BE HELD RESPONSIBLE FOR ANY INACCURACIES IN THIS HANDBOOK DERIVING FROM PRINTING OR TRANSLATION E...