For correct operation & installation it is essential to observe these instructions.

JAN2019

AS/NZS 3497

Certificate No. WM 74617 

Australian Certification Services

FP10M-2 Filter Housing

User Guide

Filtration & Ultraviolet All-in-One Undersink Unit

Hybrid-M1

Summary of Contents for Hybrid-M1

Page 1: ...tallation it is essential to observe these instructions JAN2019 AS NZS 3497 Certificate No WM 74617 Australian Certification Services FP10M 2 Filter Housing User Guide Filtration Ultraviolet All in One Undersink Unit Hybrid M1 ...

Page 2: ...urities if maintained and installed properly refer installation requirements pg 5 What s Inside Product Information Distributor Installer Phone Date Installed What s Inside Puretec Customer Service 2 Introduction 3 Positioning Your System 3 Preparing Your System 4 Installation Requirements 5 Initial Installation Procedure 6 Operation 7 Replacement Parts Guide 7 UV Lamp Installation Replacement 8 C...

Page 3: ...at 1300 140 140 Australia or 0800 130 140 New Zealand The Puretec Hybrid M1 system cartridges and lamp need replacing regularly to maintain optimum performance This is a simple procedure when following instructions For replacements contact your nearest Puretec stockist Positioning Your System Select suitable location that is close to the point of filtered water delivery e g sink Remember to allow ...

Page 4: ...tem 2 UV Lamp in cardboard tube 3 Bag containing Spanner Braided Hoses Power Cord and User Guide BRAIDED HOSES POWER CORD Preparing Your System Puretec systems are designed to run economically for many years dependent on the initial installation and periodical maintenance Please read all instructions carefully as failures caused by incorrect installation or operation are not covered by warranty On...

Page 5: ... the Hybrid system is sufficient allowing for other appliances that may be connected to the circuit and ensuring it is surge protected If in doubt please consult a qualified electrician Where the water being treated contains unusually high levels of dissolved solids particularly hard water iron manganese or biological organisms a deposit build up on the quartz sleeve may occur over time Maximum re...

Page 6: ...8 Unclip and remove the lamp from the bracket 9 Slowly insert UV lamp into chamber through the hole of the aluminium nut end Connect the lamp connector to the pins on the lamp Do not let go of the lamp until the lamp is connected to the socket Never touch the quartz glass and lamp surface as marks or fingerprints may interfere with UV transmission If lamp is soiled please clean lamp with an alcoho...

Page 7: ...o the water tank or if necessary added as a shock dose into the bowl of the filter housing of the Hybrid M1 and slowly flushed through the piping If added as a shock dose the system and pipework should be rinsed thoroughly by opening a downstream tap Replacement Parts Guide To maintain high quality purified water the cartridges will need changing periodically dependent on water quality and usage Y...

Page 8: ...d grade silicone lubricant or similar Replace O Ring if kinked or damaged UV Lamp Installation Replacement Prior to performing any work on the UV steriliser system always disconnect the power supply and allow unit to cool Warning Do not look directly into ultraviolet rays emitted from the UV lamp as they will cause serious burns to unprotected eyes The treated water will seem warm for a short peri...

Page 9: ...ubstances gathered Clean with alcohol based cleaner if necessary Quartz Sleeve Maintenance Procedure 1 Unplug the power supply Remove UV lamp before taking out the quartz sleeve and pour out water Turn counterclockwise the aluminium nut both sides of the chamber and extremely gently to remove the quartz sleeve 2 Soak a piece of cloth in vinegar or citric acid to clean the quartz sleeve 3 Put the q...

Page 10: ...imed False and incorrect claims will be pursued at Puretec s discretion including chargeable inspection and labour costs incurred Warranty Australia This warranty is given by Puretec Pty Ltd ABN 44 164 806 688 37 43 Brodie Road Lonsdale SA 5160 telephone no 1300 140 140 and email at sales puretec com au This warranty is provided in addition to other rights and remedies you have under law Our goods...

Page 11: ...11 HYBRID M1 Filtration Ultraviolet All in One Undersink Unit This page was intentionally left blank ...