Maximum runtime has been 

reached

          ,       will also be displayed.

Press for 2 seconds to unlock (       )

Vibration Detection Mode

 

(Refer to the Installation Guideline Step 7)

Hold the Power button and then 

press the Mode button

Wiring :

 Ensure the wire to be keep away from vibration detector.  

Regular Inspection : 

Keep the position of the vibration detector vertical. When performing periodic 

maintenance checks, re-run Vibration Detection Mode to ensure vibration is correctly being detected. 
Adjust position of sensor box and sensitivity as needed. 

Replacement Service Pack after the Recommended Use Time : 

If                      appears on the 

LCD after 2 years (250ml : 1 year and 6 months) from the installation date, replace the service pack 
immediately even if the grease remains in the pouch. (Dispensing failures may occur after long periods of 
time due to grease hardening and/or drops in battery voltage.) 

  Mounting Methods

  Precautions

The World Leader of Automatic Lubrication

Rev.00

  Button Operation

MODE

LOCK

Press To Select Grease Capacity  
(60/125/250ml)

 

 

TEST Mode

ON : 

Press for 2 seconds

OFF : 

Short press of button

(Will stop after completion of ongoing cycle)

Power ON/OFF

 

Hold to power unit on or off 

POWER

Reset to default setting when the 

unit malfunctions and/or after 

changing the Service Pack 

RESET

Press To Set Dispensing Period

 

1,2,3...12 month (12 Modes)

Single Point Installation

Direct Mount or Remote Installation using Extension Tubing

 

Multi-Point Installation

Multi-Point Remote Installation using Progressive Divider Block

Direct mount is always preferable. For applications not allowing 

any direct mounts, remotely mount the unit using appropriate 

accessories and keep the distance from the lube point as short as 

possible. 

For remote installation using a tube, use a 6mm O.D. (1/4") tubing 

pre-filled with the same or compatible grease as the grease 

contained in the unit.

Ensure the break-off pressure is below the average operating 

pressure of 30kgf/

cm

2

 (425psi).

  LCD Display

Dispensing period setting

Automatic Lock Out mode

Excessive backpressure / 
Operation on hold

Grease pouch capacity

Empty grease level

60/125/250

MONTH

Number of days remaining 

until dispensing period ends

Low battery power

Test Mode (PURGE Mode)

Signal lamp blinks periodically 

when battery power is low, 

excessive backpressure exists, or 

if grease level is empty

/

▶ 

Do not block any ports on divider block and use a divider    

     block corresponding to the number of ports required for multi-   

     point installation.  

     

(Ex. HU-3RS for 3 lube points, HU-5RS for 5 lube points)

▶ 

For more information, please refer to the Multi-Point Remote  

     Installation user.  

     

(Reference: Website > Service Menu > Technical Information) 

         

Warning

(60ml&125ml& 250ml)

Series

User Manual

Mi

Red

LED

Pulsarlube USA, Inc.

TEL:1-847-593-5300  FAX:1-847-593-5303  www.pulsarlube.com / [email protected]

1480 Howard Street, Elk Grove Village, IL 60007, USA

Shelf life and Warranty Product  

Warranty is limited to original defects in material and 

workmanship and will not cover any collateral damage due to mishandling, abuse and /or any 

other inappropriate use of this product. Warranty period is 1 year from the date of purchase.

 

+

TEST

Number of days passed since the 

end of dispensing period

          ,       will also be displayed.

Number of days operation has 

been on hold 

      will also be displayed.