background image

  

 

Static Eliminators

 

Instruction Manual 

Bench Top Ionizing air nozzle 
Model IN5110 

Summary of Contents for IN5110

Page 1: ...Static Eliminators Instruction Manual Bench Top Ionizing air nozzle Model IN5110 ...

Page 2: ...on and Use Environmental Conditions 2 Set up and Placement 3 Power Connection 3 3 Maintenance Periodic Maintenance 4 Cleaning Exterior 4 Cleaning Emitter Points 4 Emitter Point Replacement 5 Bracket Removal 6 Service 6 Troubleshooting 6 4 Specifications 7 5 Service and Warranty 8 6 IN5110 Line Drawing 9 ...

Page 3: ...d piezoelectric high voltage transformer makes Ptec ionizers among the most reliable ionizers manufactured Small lightweight and stable Ptec prod ucts are designed to remain in balance and to alarm when the HV output affects performance The model IN5110 benchtop static eliminator produces a 68KHz AC output of approximately 2200V and a continuous stream of bal anced air ions Ionizers that use Ptec ...

Page 4: ...front grill Adjustable air volume Power Requirements The Model IN5110 High frequency AC benchtop air ionizer is powered by an external DC switching power sup ply that operates from 100 240 VAC 50 60 Hz The output of the supply is 24 VDC 500 mA The IN5110 blower operates on an input of 24 VDC 7W Operation and Use Environmental Conditions The IN5110 can be operated in areas where humidity is 20 70 R...

Page 5: ...ertain the unit is grounded Turn the unit on to start the corona process The ion izer creates a continuous stream of positive and negative air ions The ionized airflow is directed through the front grill Charged objects in the ioniza tion area are rapidly neutralized The ion airflow is adjustable using the fan speed con trol knob The red alarm indicator light illuminates in the event of a problem ...

Page 6: ...50 de ionized water As semble it when it is dry Use the same method to clean the exterior of the unit including the inlet grill Cleaning the emitter points Contaminants will gradually accumulate on the tip of the emitter points with continuous use Periodic clean ing of the emitter points is necessary to maintain the per formance of the ionizer If the emitter points are dirty clean them with a poly...

Page 7: ...r in formation about ordering replacement emitters The part number for emitters is listed below Replacement part Part Number Tungsten replacement emitters 22 6423 Replacement Filter 22 6450 Because the IN5110 high voltage output is AC emitter erosion from the ionization process on the electrodes is minimal Unless physically broken or stressed the IN5110 emitters should last the life of the ionizer...

Page 8: ...properly turn off the unit and disconnect the power cord Contact Transforming Technologies Technical Support for repair assistance Troubleshooting The information below provides a reference for prob lems that may arise with your IN5110 benchtop blower If you have other problems not covered below please con tact Transforming Technologies Technical Support for repair assistance Problem Causes Balanc...

Page 9: ...ow 115 CFM typical high speed Noise level 60dB A Distance 1 meter Indicators Power green LED Alarm red LED Controls On Off rocker switch fan speed control Emitter points 036 dia Tungsten alloy etched Filter Replaceable Ozone 0 007 PPM Mounting Gimbaled bracket stand Dimensions 7 5 H x 7 1 W x 2 7 D 19 0 x 18 0 x 7 6 cm Weight 2 8lbs 1 27kg including stand AC DC adapter Input 100 240 VAC 50 60 Hz 0...

Page 10: ...ion or acci dent In no event shall Transforming Technologies be liable for collateral or consequential damages To receive service under warranty please con tact Transforming Technologies Technical Support About Transforming Technologies Since 1998 Transforming Technologies has helped electronic manufacturing facilities to protect their products and processes from the many serious problems associat...

Page 11: ...IN5110 Line Drawing 9 ...

Page 12: ...3719 King Rd Toledo OH 43617 P 419 841 9552 F 419 841 3241 info transforming technologies com ...

Reviews: