INSTRUCTION MANUAL

Static Remover  Fan-type Ionizer

ER-F12 / ER-F12S

Thank you very much for using Panasonic products. Please read this Instruction 

Manual carefully and thoroughly for the correct and optimum use of this product. 

Kindly keep this manual in a convenient place for quick reference.

 WARNING

Never use this product with a device for personnel protection.

 

In case of using devices for personnel protection, use products which meet laws 

or standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable 

in each region or country.

Do not use this product in places where there may be a danger of ��ammable or 

 

combustible items being present.

Clean the discharge needle regularly (about once every two weeks), otherwise 

 

optimum charge removal performance may not be obtained and ��re or operating 

problems  may occur.

If this product is used in an airtight room, ozone emitted from this product may be 

 

detrimental. Therefore, in order for this product to be used in an airtight room, be 

sure to keep the room ventilated.

Do not direct ionized air toward the face. Ozone may cause irritation to places 

 

such as the nose and throat. 

Since the tip of the discharge needle is sharp, take ���� cient care in handling the 

 

discharge needle, or injuries may result.

Be sure to ground the frame ground (F.G.) terminal, otherwise electric charge 

 

removal may not be reliable.

1

OUTLINE

This product is a fan-type charge removal device which uses ion generation from 

 

corona discharges. 

The device is suitable for a variety of charge removal applications. It is equipped 

 

with a straight louver which is ideal for long-distance charge removal, and an angle 

louver which is ideal for wide-range charge removal.

The fan speed can be adjusted to one of four settings.

 

2

PART DESCRIPTION

Caution label (Note 2)

Power switch

Power connector

LEDs

Bracket

Fan speed 

select switch 

(Note 1)

M5 screw

M5 screw

Louver

Filter cover

Description of each LED

 

POWER ...........Lights up when the power is turned on. 

(Power indicator)

DSC .................Lights up when discharge is occurring normally. 

(Discharge indicator)

DSC ERROR ...Lights up when an abnormal discharge is detected. 

(Discharge error indicator)

FAN ERROR ....Lights up when a problem with fan operation is detected. 

(Fan error indicator)

Notes: 1)  Fan speed select switch

 At the time of shipment from the factory, the device is set to fan speed 4 (MAX). Use a 

��at-tipped screwdriver to adjust the fan speed.

Notes:       

2)  Caution label

 Attach whichever accessory caution label is written in the appropriate language for the 

region of use.

3

I/O CIRCUIT DIAGRAM

4

MOUNTING

Be sure to turn off the power before carrying out angle adjustment for this product, 

 

otherwise accidents or problems with operation may occur.

Remove the bracket from the main unit, and then secure it to the installation 

 

location.

Use the holes in the base of the bracket to secure it with screws.

 

The vertical angle of the product can be freely changed by loosening the two M5 

 

screws. After adjusting the angle, retighten the screws to secure the device so 

that the angle will not change. The tightening torque for the M5 screws at this time 

��������������������������

Attach the accessory rubber cushion to bracket as shown in the below diagram to 

 

suit the usage.

5

OPERATION MATRIX

Indicators (

: Lights up, 

: Off)

Error output 

(normal 

close)

Discharge 

operation

Fan 

operation

POWER

DSC

DSC 

ERROR

FAN 

ERROR

Green

Green

Red

Red

Normal

ON

ON

ON

Discharge error

OFF

OFF

OFF

Fan error

OFF

OFF

OFF

Discharge halt input

ON

OFF

ON

*  Once an error is detected, the error status will be maintained until the power is turned off and back 

on again.

Remove the cause of the error and then turn the power back on.

If the cause of the error is not removed, the error status will continue.

* Discharge halt input is disabled when an error status is active.

6

LOUVER SELECTION

Straight louver (blue)

200mm

600mm

700mm

1500mm

Angle louver (white) (Note 1)

200mm

[Diagram with louver attached]

[Diagram of charge removal area]

This product includes two types of louver as accessories. Select the type of louver to 

use based on the charge removal area.

Straight louver

This louver provides excellent direction stability for the air. It is ideal for cases where 

rapid charge removal for objects is required, or when the object is some distance away.

Angle louver

This louver is excellent at dispersing the air. It is ideal for charge removal over a wide 

area.

Notes: 1)  The discharge needle unit is loaded on the straight louver before shipment. To replace it 

with the angle louver, refer to the discharge needle unit installation procedure in "

7

 CARE 

AND MAINTENANCE

" in this manual. 

Notes: 

2)  If no louver is attached, the device will not turn on even when the power is supplied.

7

CARE AND MAINTENANCE

Be sure to turn off the power before carrying out cleaning and maintenance.

 

The discharge needle has a sharp point, so be very careful when cleaning the needle.

 

If the device is used for a long period, dust and other foreign particles may 

 

accumulate on the discharge needles or on the fan ��lter, and so the needles and 

��lter should be cleaned before use.

If the device is not cleaned regularly, the charge removal performance will drop and 

 

operating problems or accidents may occur. Clean the device regularly, using the 

following as a guide.

Discharge needle unit: Every 2 weeks

Fan intake ��lter: Every 2 weeks

The discharge needle is a consumable part. If the discharging performance is not 

 

restored after the discharge needles have been cleaned, it is recommended that 

you replace the discharge needle unit. It is recommended that you replace the 

discharge needle unit after about 10,000 hours of operation.

Cleaning the discharge needle unit

  Check that the power is turned off and that the fan has completely stopped.

  Following the removal procedure of the louver, remove the louver from the main 

unit. 

  Clean with the discharge needle loaded. Use a cotton swab or similar tools 

moistened with alcohol to clean the discharge needles and the areas around them.

 If the needles are particularly dirty, use a brush (such as a toothbrush) moistened 

with alcohol to rub them clean, and then use a cotton swab to wipe them. 

<When using a commercially-available ultrasonic cleaner for cleaning>

Following  the  removal  procedure  of  the  discharge  needle  unit,  remove  the 

discharge needle unit from the louver, and immerse the discharge needle unit 

into the cleaning tank to clean them. After that, dry the discharge needle unit well. 

Following the installation procedure, install the discharge needle unit to the louver. 

  Following the installation procedure, install the louver to the main unit. 

[Louver removal/installation procedure]

Louver removal procedure

Louver installation procedure

When installing the louver to the main unit, align and insert the tongue of the

louver into the groove of the main unit. After inserting the tongue into the groove, 

turn the louver clockwise to install. 

* Do not touch inside the device when removing and installing the louver, otherwise accidents 

or problems with operation may occur.

[Discharge needle unit removal/installation procedure]

When using a ultrasonic cleaner for cleaning, 

remove the discharge needle unit. 

Discharge needle unit removal procedure

Discharge needle unit installation procedure

As shown in the �gure above, install the louver and the discharge needle unit so that

the claw of the louver is inserted into the hole of the discharge needle unit. (Note: 3)

Turn the discharge needle unit clockwise until it stops to install. 

Notes: 1) If replacing the louver, install the discharge needle unit to the replacement louver.

Notes: 

2)  When turning the discharge needle unit, do not apply any more force than is necessary, 

otherwise the louver or the discharge needle unit may become damaged.

Notes: 

3)  ����rm the side of the discharge needle unit to install. If installed on the wrong side, the 

discharge needle unit or the louver may become damaged. 

Option (sold separately)

ER-F12ANT

 : Discharge needle unit x 1

Cleaning and replacement procedure for fan �lter

Install a ��lter in accordance with the operating environment.

Remove the ��lter cover. Disengage the clasps in the places indicated by  in the illustration 

below, and then pull the ��lter cover in the direction of the arrow to remove it. (Refer to the 

illustration below.)

Clean away any dust and dirt adhering to the ��lter. If the ��lter is particularly dirty, 

wash it in water. If washing the ��lter in water, let it dry thoroughly before reusing it.

Install the ��lter. Install the ��lter cover.

* If the device is used while the ��lter is still wet, accidents or problems with operation may occur.

* If the ��lter will not come clean, it should be replaced.

* Be careful not to let anything get inside the device while the ��lter is removed.

Option (sold separately)

ER-F12FX5

 : Replacement ��lter x 5

Filter cover

Filter cover

Filter

Main unit

Main unit

8

TROUBLESHOOTING

Be sure to turn off the power before checking the discharge unit or the fan unit.

Problem

Main cause

Remedy

Discharge error 

indicator (DSC 

ERROR) 

lights up.

Condensation

Foreign objects

F.G. not connected

�� An abnormal discharge is probably occurring.

Turn off the power and check that the tip of the 

discharge needle is intact and free from foreign objects, 

and also check that the discharge needle unit is 

correctly installed to the louver.

�� If the error indicator remains lit even after the discharge 

needle has been cleaned, check if the area around the 

needle is dirty.

������������������.G. terminal is securely grounded.

Fan error indicator 

(FAN ERROR) 

lights up.

Fan is covered

Fan is blocked

Foreign objects

�� Turn off the power and check that the �lter is not dirty or 

blocked.

�� Check that there are no foreign objects inside the 

product.

9

SPECIFICATIONS

Type

Standard 

fan type

Low-volume fan type

Item

Model No.

ER-F12

ER-F12S

Charge removal time

1 sec. approx. (Note 1)

1.5 sec. approx. (Note 1)

Ion balance

±10 V or less (Note 2)

±10 V or less (Note 2)

Power supply voltage

24 V DC ±10%

24 V DC ±10%

Power consumption

700 mA or less

400 mA or less

Discharge method

High-frequency AC method

High-frequency AC method

Discharge output voltage

±2 kV approx.

±2 kV approx.

Max. fan speed

5.3 m/s (Note 2)

4.0 m/s (Note 2)

Max. fan volume

3.68 m

3

/min 

2.50 m

3

/min 

Error output

NPN transistor/open collector

��������������������������

��Applied voltage: 30 V DC or less (between output terminal and 0 V)

�����������������������������������������������������������

Output operation

OFF when discharge error or fan error detected

Normally ON

Short-circuit protection

Incorporated

Discharge halt output

Discharge halt: Short-circuited to 0 V

Discharge (operation start): Open

Indicators

POWER

Green LED (Lights up when power on)

DSC

Green LED (Lights up during normal discharge)

DSC ERROR

Red LED (Lights up when discharge error detected)

FAN ERROR

Red LED (Lights up when fan error detected)

Ozone generation amount

0.04 ppm or less (Note 1)

Ambient temperature

0 to + 50°C (No dew condensation) / Storage : -10 to + 65°C

Ambient humidity

35 to 65% RH (No dew condensation) / Storage : 35 to 65% RH

Vibration resistance

10 to 55 Hz frequency, 0.75 mm amplitude in X, Y and Z directions for two hours each

Material

Enclosure: ABS  Louver: ABS   Discharge needle: Tungsten

Discharge needle unit: PBT   Bracket: SPHC

Grounding method

C (capacitor) grounding

Weight

790g approx. (main unit only)

Accessories

Louvers 

            ●

Caution label: 1 set

Straight louver: 1 (Note 3 )

    ●

Rubber cushion: 1

Angle louver: 1 

Notes: 1) Typical value at 200 mm from directly in front of discharge outlet, fan speed MAX, straight 

louver, with no ��lter installed.

Notes: 

2) Typical value at 300 mm from directly in front of discharge outlet, fan speed MAX, straight 

louver, with no ��lter installed.

Notes: 

3) The discharge needle unit is loaded on the straight louver before shipment.

10

CAUTIONS

This product has been developed / produced for industrial use only.

Do not use this product for any purpose other than charge removal and dust removal.

Do not use this product in enviroments which are outside the ������cation range, 

otherwise operating problems or damage may occur. In addition, the operating life 

��������������������������������cantly reduced.

Never disassemble, repair or modify this product, otherwise operating problems or 

accidents may occur.

Do not dispose of this product by burning it, otherwise it may explode or toxic

fumes may be generated.

This product generates ozone, so be sure to provide adequate ventilation if using it 

���������ned space.

Do not run the wires together with high-voltage lines or power lines or put them in 

the same raceway. This can cause malfunction due to induction.

Be sure to turn off the air and the power supply before carrying out any cable

connection or inspection work. If this is not done, operating problems, damage or 

electric shocks may occur.

After connecting the cables, check that the connections are correct before turning on the 

power. If the cables are connected incorrectly, operating problems or accidents may occur.

Verify that the supply voltage variation is within the rating.

It takes approximately 5 seconds after the power is turned on before the fan

operation stabilizes. To ensure proper charge removal performance, do not use the 

������������������cient time has elapsed.

Do not turn the power back on immediately after it has been turned off, otherwise 

operating problems or accidents may occur. In addition, the operating life of the 

product may become ������cantly reduced. Wait at least 2 seconds before turning 

the power back on again.

Do not use any cables which have any damage (such as splitting or cracking),

otherwise operating problems or accidents may occur.

Avoid using the product in places where there are high levels of steam or dust in 

the air or where it might be directly exposed to water, oil or welding spatter.

Do not touch the discharge needle with hard objects such as tools. If the discharge 

needle becomes broken, it will not provide ����cient charge removal performance, 

and moreover operating problems or accidents may occur.

Do not use this product while the ��lter is blocked, otherwise accidents or problems 

with operation may occur.

Clean or replace the ��lter at regular intervals.

Be sure to turn off the power before replacing the ��lter.

Install the product so that it is at least 100 mm away from the objects being charged.

When installing this product, be sure to securely install the main unit and the

bracket. If they are not securely installed or if constant vibration or shocks are

applied, accidents or problems with operation may occur.

Do not place any objects which may obstruct air ��ow within 20 mm the front of the 

fan air intake, otherwise accidents or problems with operation may occur.

Use cables that are 0.15 mm

2

or more and 30 m or less in length for wiring.

Also, keep the wiring as short as possible in order to prevent naise.

If this product ceases functioning or is no longer required, dispose of it according to

appropriate local waste disposal regulations.

D

: Power supply reverse connection protection diode

D

: Output protection diode

D

: Input protection diode

Z

: Surge voltage absorption Zener diode

T

: NPN output transistor

Internal circuit

Users’ circuit

*1

Non-voltage contact or 

NPN transistor/open collector

or

Low (0V) 

: Discharge halt

High (Open) : Discharge (operation start)

Main circuit

24V DC

±10%

30V

DC max

50mA max

Error output

Discharge halt input

Load

l

Pin layout
Terminal no. Terminal name

(From cable insertion side)

F.G.

+V
0V

Error output

Discharge halt input

Recommended wire : AWG 25~12

Option (sold separately)

ER-FAPS-J

AC adapter 

About wiring cable <Recommendation>

Compatible electric wire: 

AWG25#25 - 12

(Nominal cross-sectional area: 0.16 - 3.3 m

2

)

Work dimension of electric wire: 7 mm 

(figure below)

 

*  Do not solder-plate the end of the electric wire 

to be wired to the connector. The tightened 
screw may become loose and the wiring may be 
disconnected. 

Open

Turn the louver in the direction 

of the arrow.

Remove the louver from the main unit. 

Groove of the 

main unit

Tongue of the 

louver

Hold the louver and turn the discharge needle 

unit counterclockwise. (Note: 2)

Remove the discharge needle unit from the 

louver to the direction shown in the figure.

Discharge 

needle unit 

Louver (Note: 1)

Hole of the discharge 

needle unit 

Details of the 

central part 

Claw of the louver 

MJE-ERF12F12S No.0031-23V

http://panasonic.net/id/pidsx/global

PRINTED IN CHINA