background image

 
 

 

 
 
 
 
 
 
 
 
 
 
 

 

  

 
 
 
 
 
 
 

User’s Manual 

Prudent Way 400 Watt DC-AC 
Power Inverter  
PWI-IV400 

Summary of Contents for PWI-IV400

Page 1: ...User s Manual Prudent Way 400 Watt DC AC Power Inverter PWI IV400 ...

Page 2: ...ing 2 2 Contents 3 3 Connecting the Power Inverter for loads under 150 watts 3 4 Connecting the Power Inverter for loads over 150 watts and less than 400 5 5 Special Recommendations 6 6 Measuring the AC voltage 6 7 Common Problems and Simple Troubleshooting 6 8 Specifications 7 9 1 Year Limited Warranty 8 ...

Page 3: ...urface o DO keep all body parts and or materials at least 1 5 inch away from the Power Inverter while in operation The Power Inverter may become uncomfortably hot during operating If the Power Inverter overheats it will automatically shutdown o DO make sure the ventilation openings on the Power Inverter are not obstructed Ensure the Power Inverter is never covered and always allow for proper venti...

Page 4: ...y o Wrongfully plugging the AC power outlet LINE NEUTRAL will void the warranty o Use common sense to store this Power Inverter Do not place this Inverter near any batteries gasoline explosive vapors or other flammable and dangerous materials o Please disconnect all power sources should there be anything wrong with the Power Inverter operation 2 Contents PWI IV400 DC AC Power Inverter 400 watt Cab...

Page 5: ...p This signifies the Power Inverter is operating properly and ready for use 6 Plug the AC device s into the two three prong receptacles and turn it on If you plug two devices at the same time make sure they consume 150 watts or less AC power together Picture 5 7 Turn off the Power Inverter prior to disconnect the power source Picture 1 Picture 2 Picture 3 Picture 4 Picture 5 ...

Page 6: ...ke sure to connect to the right terminals with red to red and black to black Tighten the screws on the DC input terminals Picture 3 above 4 Fasten the red positive clip to the positive battery post and then fasten the black negative clip to the negative battery post Please wear protective eyewear and clothing when you use the Power Inverter or work with the batteries Do not contact the battery ter...

Page 7: ... Be sure to disconnect the Power Inverter prior to use a battery charger to charge your battery Failure to disconnect the Power Inverter first will lead to an input surge which will damage the Power Inverter 3 Use only the cable included to connect the Power Inverter and the battery Any source of extension such as adding extension cord will result in a reduction of efficiency and output and may hu...

Page 8: ...eriod of time Simply reduce your load and allow the Power Inverter to cool down 7 Alarm is beeping Ö Alarm will be on when battery is low or the Power Inverter is over heat over temperature Please recharge battery or turn off the Power Inverter to cool down Always keep the Power Inverter away from heated sources and keep the ventilation openings in good condition 8 Red light is on Ö Red light indi...

Page 9: ...ciency or suitability of any technical or other information provided in the user manual or other documentation provided with the product Prudent Way assumes no responsibility or liability for losses damages costs or expenses whether special direct indirect consequential or incidental which might arise out of or related to the use of such information The use of any such information will be entirely...

Page 10: ...Prudent Way 400 Watt DC AC Power Inverter User s Manual Model PWI IV400 9 For support or general inquiry please contact Prudent Way Inc Toll Free 866 384 3873 Email Support prudentway com ...