background image

D55/77

OPERATION / MAINTENANCE M

ANUA

L                                                                       I

NDUSTRIAL DRYERS

DATE: 1

0

/0

2

70283601

Summary of Contents for D55

Page 1: ...D55 77 OPERATION MAINTENANCE MANUAL INDUSTRIAL DRYERS DATE 10 02 70283601 ...

Page 2: ......

Page 3: ...ccupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier W052 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other ap...

Page 4: ...2 70283601 Notes ...

Page 5: ... Model Identification 5 Wiring Diagram 5 Serial Plate Location 6 Safety Information 7 Important Safety Instructions 8 Operation 11 Emergency Stop Button On European Models 11 Operating Instructions 11 Step 1 Clean Lint Screen Compartment 11 Step 2 Load Laundry 11 Step 3 Determine Required Temperature 11 Step 4 Determine Control Type 11 Manual Timer 12 Electronic OPL Control 13 Reversing Operation ...

Page 6: ...4 70283601 Published by permission of the copyright owner DO NOT COPY or TRANSMIT Notes ...

Page 7: ...ual is applicable to these models Includes models with control suffixes Wiring Diagram The wiring diagram is located in the junction or contactor box Gas Steam 120 Pound PA120L PT120N PT120S PA120N PU120L PU120S PT120L PU120N 170 Pound PA170L PT170N PT170S PA170N PU170L PU170S PT170L PU170N RM reversing OPL Micro RT reversing manual timer ...

Page 8: ...6 Serial Plate Location When calling or writing for information about your product be sure to mention model and serial numbers Model and serial numbers are found on serial plate on rear of machine Refer to Figure 1 Figure 1 TMB1298N 1 Serial Plate TMB1298N 170 POUND TUMBLER 120 POUND TUMBLER 1 1 ...

Page 9: ...utory regulations Because of varied requirements applicable local codes should be thoroughly understood and all pre installation work arranged for accordingly NOTE The WARNING and IMPORTANT instructions appearing in this manual are not meant to cover all possible conditions and situations that may occur It must be understood that common sense caution and carefulness are factors which CANNOT be bui...

Page 10: ...l 15 If not installed operated and maintained in accordance with the manufacturer s instructions or if there is damage to or mishandling of this product s components use of this product could expose you to substances in the fuel or from fuel combustion which can cause death or serious illness and which are known to the State of California to cause cancer birth defects or other reproductive harm 16...

Page 11: ...ss 26 Always follow the fabric care instructions supplied by the garment manufacturer 27 Never operate the tumbler with any guards and or panels removed 28 DO NOT operate the tumbler with missing or broken parts 29 DO NOT bypass any safety devices 30 Solvent vapors from dry cleaning machines create acids when drawn through the heater of the drying unit These acids are corrosive to the tumbler as w...

Page 12: ...70283601 10 Published by permission of the copyright owner DO NOT COPY or TRANSMIT Notes ...

Page 13: ...y if applicable Step 2 Load Laundry Open loading door and load cylinder with laundry DO NOT OVERLOAD NOTE Overloading causes slow drying and wrinkling Close loading door Tumbler will not operate with the door open Step 3 Determine Required Temperature The type of fabric being dried will determine the setting Consult the fabric care label or fabric manufacturer to determine proper temperature setti...

Page 14: ...RE selector at HIGH MEDIUM LOW or anywhere between these settings 4 Press the PUSH TO START button in and hold it in for approximately three seconds This starts the tumbler cycle IMPORTANT If the loading door or lint panel door is opened during the cycle the heating system will shut off and the motor will stop To restart the cycle door must be closed and the PUSH TO START button must be pressed in...

Page 15: ...t damaging control or tumbler To stop the tumbler at any time open the door or press STOP RESET The window display will flash Press STOP RESET twice within 3 seconds to end the cycle and reset the control to idle status To restart the tumbler CLOSE door and press START pad IMPORTANT If the loading door or lint panel door is opened during the cycle the heating system will shut off and the motor wil...

Page 16: ...control panel area so the operator can select the reversing or nonreversing operation In nonreversing mode the cylinder will always turn clockwise as viewed from the front of the tumbler If the cylinder is turning counterclockwise when switched to nonreversing it will continue for a few seconds and then start up in the proper direction IMPORTANT After any electrical maintenance is done make sure t...

Page 17: ... allow lint to pass into the ductwork system 5 Carefully wipe any accumulated lint off of the cabinet high limit thermostat and thermistor Failure to do so will allow a buildup of lint in this area to act as an insulator causing the tumbler to overheat Refer to Figure 6 6 Replace the lint compartment panel on the tumbler ensuring a tight fit and lock if applicable Figure 6 To reduce the risk of el...

Page 18: ...p of lint which could obstruct the airflow 4 Inspect the area to make sure nothing is obstructing the flow of combustion and ventilation air 5 Remove front panel and clean any lint buildup Belt Tension Check belt tension and adjust if needed Every Six Months Overall Check Check the tumbler over thoroughly for loose nuts bolts and screws and for loose gas electrical and or steam connections GAS CON...

Page 19: ...m valve to steam tumbler before servicing Never start the tumbler with any guards panels removed Whenever ground wires are removed during servicing these ground wires must be reconnected to ensure that the tumbler is properly grounded W002 WARNING Clean air vents on drive motor Check and clean steam coils Clean exhaust ducts Check flow of combustion air Check flow of ventilation air Check belt ten...

Page 20: ...70283601 18 Published by permission of the copyright owner DO NOT COPY or TRANSMIT Notes ...

Page 21: ...Close lint panel tightly Press the PUSH TO START button Be sure power cord is plugged all the way into the electrical outlet Drying timer is in OFF position Check the main fuse and circuit breaker Check fuses located in the machine Insufficient airflow Gas shut off valve in OFF position Are controls properly set Broken drive belt Call the service person Tumbler is in Cool Down Mode Lint screen clo...

Page 22: ......

Page 23: ......

Reviews: