WE Series
Industrial/Harsh Environment Emergency Lighting
Page 1 of 2
Job Information
Type:
Job Name:
Cat. No.:
Notes:
Features
Illumination:
Illumination
is accomplished with lamp
heads externally or internally
mounted. The standard unit
with external heads includes
Lightolier’s “IT” series 6 or
12 V lamp head in a variety of
wattages. Units with internal
heads may use the 5.4 W, 7 W,
or 9 W, 6 V lamp heads.
Optional lamp heads may be
selected for external mounting
only.
Housing:
Constructed of
impact-resistant, fiberglass-
reinforced polyester. Housing
color is gray. Includes
two black, rectangular
thermoplastic 9 W lamp heads
externally mounted. Internally
mounted white or black lamp
heads available with “IH”
option (up to 25 W units only.)
One-piece, molded gasket and
unexposed metallic hardware
prolong product life in highly
corrosive areas.
Operating Temperature
Range:
Standard Location
65°F (19°C) to 85°F (30°C)
Damp/Wet Location
50°F (10°C) to 104°F (40°C)
Electronics:
120/277 VAC
dual voltage input with surge-
protected, solid-state circuitry
provides for a reliable charging
system. Charging system is
complete with low voltage
disconnect, AC lockout,
brownout protection, AC
indicator lamp and test switch.
Electrical Specifications:
0.15 A, 18 W (120 VAC)
0.07 A, 18 W (277 VAC)
Code Compliance
UL 924 and optional UL wet
and damp location listed. NFPA
101, NEC, BOCA, OSHA and
IBC illumination standards.
NSF standard 2 “Splash Zone”.
Warranty
Three year full electronics
warranty. One year full plus
four year prorated lead calcium
battery warranty. Five year full
plus five year prorated nickel
cadmium battery warranty.
WE118L2IT8
12.0"
(30.5 cm)
12.1"
(30.7 cm)
6.5"
(16.5 cm)
With internal lamp heads (IH) option.
6.5"
(16.5 cm)
12.0"
(30.5 cm)
7.1"
(18.0 cm)