GENERAL

The full-body tanner Sunstudio Combi HB 578/A is
equipped with a 30 minute timer.
After the pre-set tanning time, the appliance
automatically switches off.
The facial tanner (3 x PL 36W) can be switched on/off
by means of switch SK 1.
It has seven fans - two in the canopy and three in the 
couch - for adequate cooling of the equipment during
operation and 2 fans for body cooling.
The voltage supply will only be switched on via the
relay (Re) after the timer has been set.
The starting current is limited by NTC resistors (NTC 1-9)
and phase-correction takes place by means of the
capacitors (C 1-9).

When choosing a place for the appliance, make sure
there is enough free space around the appliance to
guarantee proper cooling.

TECHNICAL DATA

Operating voltage

:

230V, 50Hz

Power consumption

:

approx. 3050W

Ballast canopy

:

12 x 100W

:

3 x 40W

Ballast couch

:

12 x 100W

Starter type canopy

:

12 x S12

:

3 x S10

Starter type couch

:

12 x S12

Lamp type canopy

12 x Cleo Performance 100W

:

3 x PL 36W

Lamp type couch

:

12 x Cleo Performance 100W

Timer

:

30 min.

Safety class

:

double insulation

Test mark

:

CE

Length of mains cord

:

approx. 3m

Irradiation field

:

approx. 200 x 85 cm

Dimesions

:

approx. 208 x 101 x 91 cm
             ( L   x   W   x  H )

Published by Philips Domestic Appliances and Personal Care     Printed in The Netherlands      Copyright reserved     Subject to modification

©

00/05

4322 277 00342

SAP coding HB 578

!

Service

Information

!

Service

Information

Summary of Contents for SUNStudio Combi HB 578/A

Page 1: ... takes place by means of the capacitors C 1 9 When choosing a place for the appliance make sure there is enough free space around the appliance to guarantee proper cooling TECHNICAL DATA Operating voltage 230V 50Hz Power consumption approx 3050W Ballast canopy 12 x 100W 3 x 40W Ballast couch 12 x 100W Starter type canopy 12 x S12 3 x S10 Starter type couch 12 x S12 Lamp type canopy 12 x Cleo Perfo...

Page 2: ...re disassembly to make sure that they can be assembled in exactly the same position when reassembling the lamp housing which is necessary to ensure that the rivets of the cover of the lamp housing 28 can be reinserted without a problem To disassemble switches SK 1 3 52 54 the housing part 43 must be pushed inwards and downwards and kept apart with a suitable object The housing part 43 is highly fl...

Page 3: ...sassembled ASSEMBLY Canopy When assembling the acrylic sheet 45 make sure the ornamental retaining strips 3 have been snapped in properly Always use a new spring retainer 51 when reassembling the gas pressure springs 50 When assembling the housing part 43 make sure the housing part has been properly snapped in behind the metal strip Couch When assembling the acrylic sheet 9 make sure the ornamenta...

Page 4: ...ched by means of a paper clip When the couch cannot be switched on the relay on the PCB may be defective Other possible causes are a defective inlet or a defective connecting cable Always use protecting goggles when looking in the direction of burning lamps The acrylic sheets can be cleaned with a moist cloth and some washing up liquid Avoid the use of alcohol alcohol based cleaners petrol acetone...

Page 5: ... minutes in the centre of the irradiation field and at the distance indicated The following aspects must be checked or the following preliminary measurements must be taken Mains voltage 230V Room temperature approx 22 28 C Check the fans for failure free operation as optimal irradiation is only guaranteed at the correct operating temperatures Clean the reflectors the lamps and the acrylic sheets W...

Page 6: ...ble 30 4222 062 94290 remote controle with cable 31 4822 116 30297 NTC resistor 32 4822 265 30284 connecting block for NTC 33 9965 000 03044 screw plug 34 9965 000 02739 set of 5 caps and rings 35 9965 000 01954 end cover canopy L 36 4822 502 14539 s t screw 4 8x19 37 4822 532 12791 push rivet 6x7 5 38 9965 000 03628 cover canopy 39 9965 000 01942 side cover front couch canopy 40 9965 000 01953 en...

Page 7: ...40 Watt 100 Watt HB 578 A NTC 1 2 3 4 5 8 9 10 11 12 13 14 15 16 17 6 7 69 16 29 30 18 33 19 20 21 22 23 24 25 26 27 28 31 32 ...

Page 8: ...34 35 37 38 40 42 43 44 45 46 47 50 51 52 54 48 49 53 55 39 36 60 61 62 63 Reflector diagram couch canopy 67 66 68 AIR 67 65 66 64 ...

Page 9: ...24 Fan Fan Fan M6 M7 M8 Power board Remote Control S14 L14 La14 S15 L15 La15 S16 L16 La16 S17 L17 La17 S18 L18 La18 S19 L19 La19 S20 L20 La20 S21 L21 La21 S22 L22 La22 S23 L23 La23 Lowerpart Couch M M M t 28µF C1 9 NTC1 9 9x ...

Page 10: ...y cooler S2 L2 La2 S3 L3 La3 S4 L4 La4 S5 L5 La5 S6 L6 La6 S7 L7 La7 S8 L8 La8 S9 L9 La9 S10 L10 La10 S11 L11 La11 Fan Fan M M SK4 SK1 SK3 Upper part Canopy M2 M3 DAP1034 S25 L25 La25 S26 L26 La26 S27 L27 La27 Fan M4 Fan M5 M M ...

Page 11: ...6 5 4 3 2 1 100 W L6 100 W L5 1 100 W L9 100 W L10 1 M4 S25 S26 S27 La25 L25 L26 L27 La26 La27 La1 La3 La2 La4 La5 La6 La7 La8 La9 La10 La11 La12 SK1 PL on off SK3 Fan on off SK4 Fan H L supply of Couch 40 W 40 W 40 W ...

Page 12: ... 100 W L5 100 W L4 100 W L3 100 W L2 100 W L1 100 W L10 100 W L11 100 W L12 100 W L7 100 W L8 M4 M5 M2 M3 HB 578 Canopy S1 La1 S3 La3 S2 La2 S4 La4 S5 La5 S6 La6 S7 La7 S8 La8 S9 La9 S10 La10 S11 La11 S12 La12 ...

Page 13: ...4 L13 100 W L16 100 W L19 100 W L14 100 W L17 100 W L20 100 W L15 100 W L18 C1 C2 C3 C4 C5 C6 C7 7 6 5 4 3 2 1 NTC 100 W L21 S15 La15 S16 La16 M6 M7 M8 S17 La17 S18 La18 S19 La19 S20 La20 S21 La21 S22 La22 S23 La23 S24 La24 ...

Page 14: ... to Canopy Mains connection 12 11 10 9 8 7 6 5 4 3 2 1 DAP1032 100 W L22 100 W L19 100 W L23 100 W L20 C6 C7 7 8 9 6 C8 C9 100 W L24 100 W L21 La13 La14 La15 La16 La17 La18 La19 La20 La21 La22 La23 La24 HB 578 Couch HB 579 Couch ...

Reviews: