Should the installer or owner be unfamiliar

with  the  correct  installation  or  operation  of
this  type  of  equipment  you  should  contact

the  distributor/manufacturer  for  the

correct  advice  before  proceeding  with  the

installation or operation of the product.

An earth leakage or residual

current  protection  device  must  be  fitted  to

all installations.

O

W

N

E

R

’S 

M

A

N

U

A

L

Pool Products

MAX-E-PRO

TM

POOL PUMP

MaxEPro_OwnersManual_2012

Monday, 17 December 2012 10:03:44 AM

Summary of Contents for MAX-E-PRO

Page 1: ...ntact the distributor manufacturer for the correct advice before proceeding with the installation or operation of the product An earth leakage or residual current protection device must be fitted to all installations OWNER S MANUAL Pool Products MAX E PROTM POOL PUMP MaxEPro_OwnersManual_2012 Monday 17 December 2012 10 03 44 AM ...

Page 2: ... with Health Authority Regulations Max Ambient Temperature 500 C IP Rating IP25 Electrical Rating 240 Volt single phase are supplied as standard with built in thermal overload protection and are designed to plug directly into a 10 amp 15 Amp for MP2201100 domestic power supply to local electrical authority specifications 415 Volt 3 phase motors should be protected with the recommended contactor an...

Page 3: ...g safety checks Check all clamps bolts lids and system accessories prior to testing Release all air in system before testing Tighten trap lid to 4 1 kg m torque for testing Water pressure for test must be less than 172kPa 25 PSI Water temperature for test must be less than 35 C Limit test to 24 hours After test visually check system to be sure it is ready for operation Remove trap lid and retighte...

Page 4: ...below the motor s rated ambient temperature whenever the pump is running Be solid Level Rigid Vibration free To reduce vibration and pipe stress bolt pump to mount Allow pump suction inlet height to be as close to water level as possible Allow use of short direct suction pipe to reduce friction losses Allow for shut off valves in suction and discharge piping Have adequate floor drainage to prevent...

Page 5: ... airlocking slope suction pipe slightly upward toward the pump NOTICE To prevent flooding when removing pump for service all flooded suction systems must have shut off valves in suction and discharge pipes Fittings Fittings restrict flow for best efficiency use fewest possible fittings Avoid fittings which could cause an air trap Pool outlets Use only non entrapping suction fitting or double sucti...

Page 6: ...ntrapment entanglement Suction Outlet Covers All suction outlet covers must be maintained They must be replaced if cracked broken or missing See below for outlet cover certification requirements All suction outlets must have correctly installed screw fastened covers in place Testing and Certification Suction outlet covers must have been tested by a nationally recognised testing laboratory and foun...

Page 7: ... system Exactly match supply voltage to motor nameplate voltage Incorrect voltage can cause fire or seriously damage motor and voids warranty If in doubt consult a licensed electrician The pump is to be supplied by an isolating transformer or supplied through a residual current device RCD having a rated residual operating current not exceeding 30 mA If the supply cord is damaged it must be replace...

Page 8: ...tended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure they do not play with the appliance Fire and burn hazard Modern motors run at high temperatures To...

Page 9: ...ll on trap Replace trap cover and handle ring on trap turn handle ring clockwise to tighten cover NOTICE Tighten trap cover handle ring by hand only no wrenches Pump should prime now Priming time will depend on vertical height of suction lift and horizontal length of suction piping The self priming time range is 1 to 5 minutes for a height difference of 2 to 3 metres under normal installation cond...

Page 10: ... O ring groove on trap body and replace cover and handle ring To help keep cover from sticking tighten hand tight only 6 Prime pump refer priming instructions Pump Service Pump should only be serviced by qualified personnel For best results use only genuine Pentair factory parts Be sure to prime pump before starting Before removing clamp or trap cover 1 SWITCH OFF POWER to pump before proceeding 2...

Page 11: ... five screws and washers holding diffuser to seal plate Remove the diffuser 5 Remove motor cowl and motor fan 6 Hold shaft with an open end wrench or vice grips on motor shaft flats 7 Unscrew impeller from shaft turn counterclockwise when facing it NOTICE On models with impeller screw Remove impeller screw left hand thread turn clockwise and gasket before removing impeller Inspect gasket for damag...

Page 12: ...over impeller sleeve until rubber drive ring hits shoulder NOTICE Be sure not to nick or scratch polished seal face seal will leak if face is damaged 7 Screw impeller onto shaft clockwise this will automatically locate seal in seal plate NOTICE On models with impeller screw Install impeller gasket and lock screw left hand thread turn counterclockwise to tighten Torque lock screw to 57 6 63 kg cm 8...

Page 13: ... Make sure that the impeller is not clogged This should be checked by qualified personnel only Impeller and diffuser may be worn If so check with your local Pentair dealer or suitably qualified personnel Clogged pipe strainer impeller worn impeller Pump may be trying to push too high a column of water If so a higher head pump is required No power at outlet Use another electrical appliance that is ...

Page 14: ...owly Pump may be too hot Check line voltage if less than 90 or more than 110 of rated voltage consult a licensed electrician Increase ventilation Reduce ambient temperature Tighten any loose connections Pump leaking from between the casing and motor Casing bolts are not tightened sufficiently Casing O ring is worn Mechanical seal requires replacing Casing clamp is loose Switch off the power to the...

Page 15: ...15 MaxEPro_OwnersManual_2012 Monday 17 December 2012 10 03 46 AM ...

Page 16: ... 1 1 1 801275 801275 801275 801275 801275 801275 801275 801275 1 C8 58P C8 58P C8 58P C8 58P C8 58P C8 58P C8 58P C8 58P 2 800405 800405 800405 800405 800405 800405 800405 800405 2 SRU30 918SS SRU30 918SS SRU30 918SS SRU30 918SS SRU30 918SS SRU30 918SS SRU30 918SS SRU30 918SS 1 801276 801276 801276 801276 801276 801276 801276 801276 2 2 2 2 801245 801245 801245 801245 801245 801245 801245 801245 1...

Page 17: ...NOTES MaxEPro_OwnersManual_2012 Monday 17 December 2012 10 03 46 AM ...

Page 18: ...NOTES MaxEPro_OwnersManual_2012 Monday 17 December 2012 10 03 46 AM ...

Page 19: ...NOTES MaxEPro_OwnersManual_2012 Monday 17 December 2012 10 03 46 AM ...

Page 20: ...o publish the correct details in this data sheet No responsibility will be taken for errors omissions or changes in product specifications Pentair Water reserves the right to change specifications Head Office Pentair AU NZ 1 21 Monash Drive Dandenong South Vic 3175 Australia National Customer Service Phone 1300 137 344 Fax 1800 006 688 National Dealer Locator Phone 1800 664 266 Email au sales pent...

Reviews: