background image

ISSUED: 02-05-09   SHEET #: 202-9331-1

Installation and Assembly:

Smartmount

®

 Universal Flat Wall Mount for 37" - 60" 

(94 - 152 cm) Flat Panel Screens

Features:

 

•  Screen held only 1.75" (44 mm) from wall for a discreet application

  Open wall plate design allows for additional wall access, increasing 

electrical access and cable management options

•  Universal screen mounting brackets hook onto the wall plate for quick, 

easy, and safe installation

•  Includes Sorted-For-You™ fastener pack for installation to wood studs, 

concrete and cinder block

•  Optional horizontal adjustment of up to 8" (203 mm) (depending on 

screen model) for perfect screen placement

•  Available in black and silver

Models:

 D-FPF-320, D-FPF-320S, SF660, SF660-S, SF660P, SF660P-S, RTFPF-320, 

RTFPF-320I, RTFPF-320S, RTFPF-320SI, SWS410/BK, SWS410/SI

Max Load Capacity:  200 lb (91kg)

©

UL

US

C

ID

: 0

0000187

62

Summary of Contents for Smartmount

Page 1: ...ent options Universal screen mounting brackets hook onto the wall plate for quick easy and safe installation Includes Sorted For You fastener pack for installation to wood studs concrete and cinder block Optional horizontal adjustment of up to 8 203 mm depending on screen model for perfect screen placement Available in black and silver Models D FPF 320 D FPF 320S SF660 SF660 S SF660P SF660P S RTFP...

Page 2: ...attached hardware and components Never exceed the Maximum Load Capacity See page one If mounting to wood wall studs make sure that mounting screws are anchored into the center of the studs Use of an edge to edge stud finder is highly recommended Always use an assistant or mechanical lifting equipment to safely lift and position equipment Tighten screws firmly but do not overtighten Overtightening ca...

Page 3: ...RTFPF 320I RTFPF 320 D FPF 320 RTFPF 320SI RTFPF 320S D FPF 320S Description Qty SF660 Part Number SF660 S Part Number SF660P Part Number SF660P S Part Number AA wall plate 1 201 1503 201 4503 201 1503 201 4503 BB deep adapter bracket 2 201 1510 201 4510 201 1513 201 4513 CC shallow adapter bracket 2 201 1511 201 4511 201 1514 201 4514 DD 14 x 63 5 mm wood screw 4 5S1 015 C03 5S1 015 C03 5S1 015 C...

Page 4: ...ll plate may be mounted up to 6 5 165 mm off center as shown in figure 1 1 Skip to step 2 Installation to Double Wood Stud Wall 1 Installer must verify that the supporting surface will safely support the combined load of the equipment and all attached hardware and components Tighten wood screws so that wall plate is firmly attached but do not overtighten Overtightening can damage the screws greatly ...

Page 5: ...ering a void or cavity Concrete must be 2000 psi density minimum Lighter density concrete may not hold concrete anchor Make sure that the wall will safely support four times the combined load of the equipment and all attached hardware and components WARNING Tighten screws so that wall plate is firmly attached but do not overtighten Overtightening can damage screws greatly reducing their holding pow...

Page 6: ...ts are firmly attached Do not tighten with excessive force Overtightening can cause stress damage to screws greatly reducing their holding power and possibly causing screw heads to become detached Tighten to 40 in lb 4 5 N M maximum torque If screws don t get three complete turns in the screen inserts or if screws bottom out and bracket is still not tightly secured damage may occur to screen or pro...

Page 7: ...y Chart to determine the proper fastener to use Visit www peerlessmounts com 6 for a full screen compatibility chart for this mount Begin with longer length screw hand thread through multi washer adapter bracket BB or CC and spacer in that order into screen as shown below Screw must make at least three full turns into the mounting hole and fit snug into place Do not over tighten If screw cannot mak...

Page 8: ...s section To remove screen from mount loosen safety security screws swing screen away from mount and lift screen off of mount 3 Always use an assistant or mechanical lifting equipment to safely lift and position the flat panel screen WARNING Do not tighten screws with excessive force Overtightening can cause damage to mount Tighten screws to 40 in lb 4 5 N M maximum torque CAUTION fig 3 2 2009 Peerl...

Page 9: ...ngsoptionen Schnelle einfache und sichere Anbringung durch Einhaken der Universal Bildschirmmontagehalterungen an der Wandplatte Einschließlich Sorted For You Befestigungsteilesortiment zur Anbringung an Holzständern Beton und Porenbetonstein Optionale horizontale Verstellung bis zu 203 mm 8 Zoll abhängig vom Bildschirmmodell ermöglicht optimale Platzierung des Bildschirms In Schwarz oder Silber v...

Page 10: ... sich ein Balkenfinder mit genauer Kantenanzeige Ziehen Sie immer eine zusätzliche Person heran oder verwenden Sie mechanische Hebegeräte um Geräte sicher zu heben und zu positionieren Ziehen Sie die Schrauben fest an ohne sie zu überdrehen Durch Überdrehen können die Teile beschädigt werden wodurch ihr Haltevermögen stark reduziert wird Dieses Produkt ist nur für den Gebrauch innerhalb von Gebäude...

Page 11: ...5 C03 5S1 015 C03 5S1 015 C03 5S1 015 C03 EE butondübel 4 590 0320 590 0320 590 0320 590 0320 FF 4 mm Inbusschlüssel 1 560 1146 560 1146 560 1146 560 1146 Teileliste Vergewissern Sie sich vor Beginn der Arbeiten dass alle dargestellten Teile mit Ihrem Produkt mitgeliefert wurden Die Teile können etwas anders als in der Abbildung aussehen Kipphalterungen Befestigungsteilesortiments M4 x 12 mm 4 504...

Page 12: ...3 5 mm Holzschrauben DD HINWEIS Die Wandplatte kann wie in Abbildung 1 1 dargestellt bis zu 165 mm 6 5 Zoll außermittig angebracht werden FAHREN SIE MIT SCHRITT 2 FORT 1 6 5 165 mm AA DD AA CS 4 08 157 5 mm 6 5 165 mm Anbringung an Wand mit zwei Holzständerreihen Bei der Anbringung muss darauf geachtet werden dass die Wand die kombinierte Last von Bildschirm und allen Befestigungsteilen und kompon...

Page 13: ...M Norm C 90 entsprechen Wir empfehlen zum Bohren des Lochs anstelle eines Schlagbohrers einen standardmäßigen Elektrobohrer bei niedriger Einstellung zu verwenden um zu verhindern dass die Bohrungsrückseite beim Eintritt in einen Leer oder Hohlraum ausbricht Die Betondruckfestigkeit muss mindestens 2000 psi betragen In Beton mit geringerer Druckfestigkeit kann der Betondübel u U nicht halten Verge...

Page 14: ... sicher befestigt sind Ziehen Sie die Schrauben nicht zu fest an Durch die beim Überdrehen entstehende Spannung können die Schrauben beschädigt werden was ihr Haltevermögen stark reduziert und möglicherweise dazu führen kann dass die Schraubenköpfe sich lösen Das maximale Drehmoment zum Festziehen der Schrauben darf 40 in lb 4 5 Nm nicht überschreiten Sind die Schrauben nicht um drei volle Umdrehu...

Page 15: ...BE SCHRAUBE Bildschirme mit Wölbung oder Vertiefung an der Rückseite Wenden Sie sich mit Fragen an den Peerless Kundendienst unter der Telefonnummer 1 800 865 2112 innerhalb der USA oder besuchen Sie unsere Website www peerlessmounts com 6 Beginnen Sie mit der längeren Schraube und schrauben Sie diese in der unten abgebildeten Reihenfolge von Hand durch die Mehrlochscheibe die Adapterhalterung und...

Page 16: ...nittbild dargestellt Zum Entfernen des Bildschirms vom Halter lösen Sie die Sicherheitsschrauben schwenken den Bildschirm vom Halter weg und heben ihn vom Halter ab 3 BB oder CC BB oder CC AA 2009 Peerless Industries Inc Alle Rechte vorbehalten Alle anderen Marken und Produktnamen sind eingetragene Marken der jeweiligen Eigentümer Peerless Industries Inc 3215 W North Ave Melrose Park IL 60160 www ...

Reviews: