INSTRUCTION SHEET 

G3 DUAL DEADMAN 14.5 PSI CUSHION CONTROLLER 

P/N: 22-887305G3 

 

FEATURES:

 

 

 
 
 
 

 

 

VENTED QUICK CONNECT OPEN COUPLING, 
INLET HOSE TO PRESSURE REGULATOR OR 
REGULATED AIR SOURCE 

QUICK CONNECT OPEN COUPLINGS 

 
IN-LINES TO HOSES & CUSHIONS 

HIGH VISABILITY GAUGES 

 
PROTECTED BY CONTROLLER 
BODY 

GAUGE LIGHT 

 
TO VIEW DURING LOW 
LIGHT SITUATIONS 

PROTECTED 14.5 PSI PRESSURE RELIEF 
VALVES 

– 40 MICRON POROUS FILTER 

 
TO PREVENT OVER PRESSURIZATION OF 
CUSHIONS 

INFLATE BUTTONS - GREEN 

DEFLATE BUTTONS - RED 

Содержание G3 DUAL DEADMAN

Страница 1: ... INSTRUCTION SHEET G3 DUAL DEADMAN 14 5 PSI CUSHION CONTROLLER P N 22 887305G3 FEATURES VENTED QUICK CONNECT OPEN COUPLING INLET HOSE TO PRESSURE REGULATOR OR REGULATED AIR SOURCE QUICK CONNECT OPEN COUPLINGS IN LINES TO HOSES CUSHIONS HIGH VISABILITY GAUGES PROTECTED BY CONTROLLER BODY GAUGE LIGHT TO VIEW DURING LOW LIGHT SITUATIONS PROTECTED 14 5 PSI PRESSURE RELIEF VALVES 40 MICRON POROUS FILTE...

Страница 2: ...21 Back mount 1 5 38 1 mm with 14 5 psi 1 0 bar green scale and 14 5 30 psi 1 0 2 07 bar red scale Used to monitor system pressure the gauge is installed inside the controller housing see maintenance section for installation procedure Gauge weight 20 lbs 09 kg 2 G3 Deadman Gauge Light PN 22 890862 Ultra bright white LED flashlight with black polyurethane housing and PARATECH logo IPX 7 rated with ...

Страница 3: ...ed coupling is required to be rotated to the full lock position or the system will leak 1 Attach the inlet quick connect vented coupling on the G3 Cushion Controller to a regulated air source 2 Attach a safety inline relief valve to the outlet delivery quick connect couplings being used on the G3 Cushion Controller Check that the safety inline relief valve shut off valves are closed full clockwise...

Страница 4: ...uge in place and separate the gauge from the controller 2 Place the flats of the gauge base into a vice and unscrew using a 9 16 14 mm open end wrench 3 Discard the damaged gauge and replace it with PARATECH PN 22 890621 4 Apply 2 wraps of Teflon tape on the new gauge threads NOTE to prevent system contamination keep tape off of the bottom 2 gauge threads 5 Screw gauge back into the base and retig...

Страница 5: ...1 Using a T20 Torx Driver remove the 2 screws to the upper left and right of the gauge light 2 Fold back the cover plate to expose the gauge light NOTE The cover plate has been designed with a living hinge so it will not be damaged by folding back on itself 3 Remove and discard the old gauge light and replace it with PARATECH PN 22 890862 4 Fold the cover plate down and reinstall the 2 T20 Torx sc...

Страница 6: ...ch of Paratech Inc P O Box 1000 Frankfort IL 60423 USA P O Box 174 5260 Odense S Denmark Customer Service 800 435 9358 www paratech com Email Paratech paratech dk Phone 815 469 3911 Fax 815 469 7748 www paratech com E mail paratech paratech us ...