background image

P R E - I N S T A L L A T I O N

O A S   W A L L - I N T E G R A T E D   R 3

5-06-0009

Publication date 2020-02-27

Summary of Contents for Oas

Page 1: ...PRE I NSTALLATION O A S W A L L I N T E G R A T E D R 3 5 06 0009 Publication date 2020 02 27 ...

Page 2: ...cument may be reproduced or copied in any form or by any means without written permission from Orbital Systems The English language version of this document contains the original in structions All other language versions are translations of the original instructions ...

Page 3: ... Installation 6 Shower Installation Overview 7 Recycling Optimisation Site Suggestion 8 Pre Installation 9 Component Overview 9 Kit Measurements 10 Crucial Kit Measurements 11 Prepare Shower Area 12 Install Drain 14 Install Diverter Wall Bracket 16 Prepare OS Head Shower 16 Prepare 3rd Party Head Shower 17 Prepare for Tiling 17 Tiling 20 Pipes Connections 22 Final Preparations 24 Pre installation ...

Page 4: ...This page is intentionally left blank ...

Page 5: ...328 v2 1 1 EN 301 489 1 v2 1 1 EN 301 489 17 v3 1 1 EN 300 330 v2 1 1 EN 62311 2008 EN 60335 2 105 2005 A1 A11 Additional standard that has been applied to the product UL 1951 IGC 330 18 FCC Part 15 B EN 1717 BBR NSF55 EN 13076 The product has undergone mandatory or voluntary certification procedures in order to receive the following certifications KIWA TG 1503 KIWA K100686 01 IAPMO E10059 IAPMO C...

Page 6: ...the shower to clean extreme soil ing or pour corrosive chemicals or cleaners down the shower drain Any other use of the system could seriously deteriorate the quality of the filtration system or damage the show er system Do not drink the shower water Quality of the water is not guaranteed to meet drinking wa ter quality These instructions are provided to advise the best practice for the installati...

Page 7: ...d under strict standards Orbital Systems warranty covers defects which appear within a period of two years from delivery of the product Orbital Systems warranty does not cover Defects arising out of materials or a design specified by the Customer or by any alter ations carried out without our consent Defects that appear under conditions of operation not provided for and under im proper use of the ...

Page 8: ...ould you require product advice experience any problems need to purchase spare parts or to set up a service visit Repairs should always be carried out only by Orbital Systems Contact us support orbital systems com www orbital systems com Europe CET 46 0 40 619 55 50 Pre installation 4 ...

Page 9: ... mm 812 mm 440 mm Ø 75 mm 600 mm 0 mm OS Head Hand Shower 1000 mm INFORMATION VALID FOR ALL SHOWER VARIANTS Picture displaying OS Head Hand Shower variant 2190 mm 575 mm 150 mm 1266 mm 2190 mm 150 mm 1266 mm 184 mm 122 mm 145 mm 3rd Party Shower Ø 50 mm 1540 mm Pre installation 5 ...

Page 10: ... 4 GHz required Circuit breaker One per shower required Plumbing Water Hot and Cold Water Inlet Separate hot cold inlet required 1 2 BSPP G pipe connection needed Temperature of inlet water Cold 4 C to 30 C Hot 55 C to 70 C Water inlet flow Min 9 litres minute hot and cold Water pressure Min 3 bar 43 5 psi 0 3 MPa measured at the highest point of installation Max pressure 10 bar 145 psi 1 MPa Hard...

Page 11: ...re Wall Enclosure HxWxD 932 x 538 x 145 mm Available Shower variants A OS Head Hand Shower B OS Head Shower C 3rd Party Shower 4 5 6 8 3 2 1 7 1 Shower Unit Core 2 Core Wall Enclosure 3 Control Dial 4 Shower Head 5 Hand Shower 6 Hand Head Diverter 7 Drain Unit 8 Smart Sensor Unit and Sensor Tank Pre installation 7 ...

Page 12: ...STION Recommended installation A fully enclosed shower space with floor heating is recommended to optimize recircu lation rates INFORMATION VALID FOR ALL SHOWER VARIANTS Picture displaying OS Head Hand Shower variant Pre installation 8 ...

Page 13: ...P R E I N S T A L L A T I O N COMPONENT OVERVIEW 2 3 4 5 11 OS Head Hand Shower 12 6 1 7 13 14 Pre installation 9 ...

Page 14: ...r Cable and corrugated sleeve 11 Grating 12 Hand Head Diverter kit Countersunk stainless Screw x3 13 Pipe Clamps x2 14 Pipe Support Sleeves KIT MEASUREMENTS 440 mm 932 mm Ø40 mm 184 mm 150 mm 192 mm 122 mm 201 mm 754 mm 726 mm 812 mm 690 mm Ø75 mm 114 mm cc 40 mm 853 mm 452 mm 538 mm 90 mm 150 mm 145 mm NOTICE Use the two 45 degree pipe elbows included in the kit for the drain A 90 degree elbow wi...

Page 15: ...CRUCIAL KIT MEASUREMENTS 2125 mm 600 mm 1000 mm X X X Finished floor height where it is level CAUTION Crucial measurement Pre installation 11 ...

Page 16: ...pace for the Drain Unit 2 145 mm 442 mm X X Finished floor height where it is level 3 CAUTION Crucial that all noggin pieces are in level and set according to rec ommended measurements to avoid misalignment in the shower installation 80 mm 45 mm 85 mm 85 mm 2100 mm 145 mm 45 mm X X Y X Finished floor height where it is level Y Wall thickness after completed instal lation Pre installation 12 ...

Page 17: ...cording to local regulations 5 Valid for OS Head Hand Shower 1620 mm 145 mm 50 mm 145 mm 45 mm NOTICE It s optional which side of the shower the Diverter is placed Mirror slot in stud and wall cover ing if needed Pre installation 13 ...

Page 18: ...inless Steel Screw Choose the 5 holes that fits the noggins best There are holes at the distance of 300 mm 600 mm and then outer cor ners and the middle 2 Next step depends on Shower variant Follow steps valid for OS Drain Step 3 3 Valid for OS Drain 30mm X X Z Z X Finished floor height where it is level Z Drain Unit is centered in the shower space 4 Connect Drain Unit to the sewerage sys tem as d...

Page 19: ...1 NOTICE Apply lubricant 2 NOTICE Anchors provided by Customer Anchor the Drain Piping according to lo cal regulations Pre installation 15 ...

Page 20: ...e in slot in stud and anchor with Pipe Clamp PREPARE OS HEAD SHOWER 1 1 2125 mm Measure and mark placement of Wall box UNI Push 2 x4 Pan Head Stainless Steel Screw Follow instructions provided in installa tion box for the Wall box UNI Push Should be performed according to local regulations by a licensed professional Pre installation 16 ...

Page 21: ...system performance Should the combined coun ter pressure from the diverter and head hand shower exceed 1 bar at 10 L min it will affect the lifespan of the filter capsule negatively A combined counter pressure exceeding 1 5 bar at 10 L min is not recom mended Any installed head hand showers should allow for a water flow of min 9 L min It is recommended to install diverters de signed for wall integ...

Page 22: ...tions min 2 inclination to wards the Drain Unit 4 Clean the metal flanges of the Drain Unit and the Core Wall Enclosure 5 6 X X X Install waterproof membrane according to local regulations Make sure they cover the metal flanges of the Drain Unit and the Core Wall Enclosure according to membrane supplier recommendation X Pre installation 18 ...

Page 23: ...7 4 8 Adjust x4 M3 5 5 mm driver Secure Pre installation 19 ...

Page 24: ...9 Apply mortar up to the sides of the Frame TILING 1 0 Apply tiles up against the lacquered line on all sides of the flange of the Wall box Pre installation 20 ...

Page 25: ...Min 5 16 Max 5 8 Ø 1 3 16 Cut holes in tiles for water connections Create a slot between the holes and fill the slot with grouting up to tile level 3 NOTICE Floor tiles must be level with or higher than the Frame Make sure the tiles do not overlap the Grating allowing it to be removed 4 2 mm 2 mm Pre installation 21 ...

Page 26: ...egula tions 6 11 PIPES CONNECTIONS 9 10 NOTICE Provided by Customer PEX hose with corrugated sleeve 1 CAUTION The Core shall be connected to the top inlet CAUTION The Shower Head shall be con nected to the bottom inlet Pre installation 22 ...

Page 27: ...g on the diameter of the hose 3 4 CAUTION Cut the corrugated sleeve as close as possible to the water tight seal 50 mm Cut the corrugated sleeves 5 NOTICE Anchors provided by Customer 6 Secure Pipe in slot in stud and anchor with Pipe Clamp Pre installation 23 ...

Page 28: ...e performed according to local regulations by a licensed electri cian FINAL PREPARATIONS CAUTION The shower will not function without executing above mentioned steps Pre installation completed Next step is to install the Shower Unit Show er Head and Hand Shower including Diverter and Holder See Installation manual for de tails Pre installation 24 ...

Page 29: ...C E R T I F I E D S P A C E T E C H N O L O G Y ...

Reviews: