background image

Revised - 08/18/2022

Toll Free: 1-800-465-0234

Fax: 905-607-0234

Email: [email protected]

www.omcan.com

Refrigerated Prep Tables

Models PT-CN-1524-S-HC, 1778-S-HC

Items 50089, 50090

Instruction Manual

Summary of Contents for PT-CN-1524-S-HC

Page 1: ...Revised 08 18 2022 Toll Free 1 800 465 0234 Fax 905 607 0234 Email service omcan com www omcan com Refrigerated Prep Tables Models PT CN 1524 S HC 1778 S HC Items 50089 50090 Instruction Manual...

Page 2: ...ble of Contents Section Disclaimer General Information Safety and Warranty Technical Specifications Installation Operation Maintenance Troubleshooting Parts Breakdown Electrical Schematics Warranty Re...

Page 3: ...T RESPONSIBLE FOR DIMINISHED COOLING OR ANY DAMAGES DUE TO WATER LEAKS WARRANTY IS VOID IF THE AMBIENT ROOM TEMPERATURE EXCEEDS 75 F AND 55 RELATIVE HUMIDITY AND THE APPLIANCE DRAIN IS NOT CONNECTED D...

Page 4: ...importance to save these instructions for future reference Also save the original box and packaging for shipping the equipment if servicing or returning of the machine is required Omcan Fabrication e...

Page 5: ...ior Habra el carton para asegurararse que todos los articulos solicitados sten dentro de la caja y no encuentre da os ocultos en la m quina Si el paquete ha sufrido un manejo de poco cuidado golpes o...

Page 6: ...lead to serious injury and or damage to the unit ATTENTION To minimize shock and fire hazards be sure not to overload outlet Please designate one outlet for your unit Do not use extension cords Do no...

Page 7: ...34 to schedule a drop off to either an Omcan authorized service depot in the area or to an Omcan Service warehouse to repair the equipment Unauthorized maintenance will void the warranty Warranty cove...

Page 8: ...Packaging Dimensions 63 x 32 3 x 43 7 1600 x 820 x 1110mm 73 1 x 32 3 x 43 7 1857 x 820 x 1110mm Packaging Weight 412 3 lbs 187 kgs 454 2 lbs 206 kgs Item Number 50089 50090 IMPORTANT PLEASE READ BEFO...

Page 9: ...r energy bills and gradual breakdown of the unit With the lid open the unit should not be used in areas over 80 degrees The unit should not be used in areas over 90 degrees Malfunction due to high amb...

Page 10: ...oduct Blocking the evaporator fans will result in a warmer cabinet temperature and ultimately compressor failure RUNNING A MANUAL DEFROST CYCLE This unit is pre programmed to run automatic defrost cyc...

Page 11: ...OR OF UNIT When cleaning the cabinet interior use a solvent of warm water and mild soap Do not use steel wool caustic soap abrasive cleaners or bleach that may damage the stainless steel surface Wash...

Page 12: ...orator coil iced over Unplug unit and allow coil to defrost Make sure thermostat is not set too cold Ensure that door gasket s are sealing properly Cabinet Temperature is too Warm Thermostat set too w...

Page 13: ...13 Parts Breakdown Model PT CN 1524 S HC 50089...

Page 14: ...Upper Left Hinge for 50089 9 AI958 Top Board Connector for 50089 28 AI969 Filter Fixer for 50089 47 26884 K Clip for 50089 10 AA596 Thermometer for 50089 29 AI970 Compressor Parts for 50089 48 AF090 K...

Page 15: ...15 Parts Breakdown Model PT CN 1778 S HC 50090...

Page 16: ...Left Hinge for 50090 9 AI958 Top Board Connector for 50090 28 AI969 Filter Fixer for 50090 47 26884 K Clip for 50090 10 AA596 Thermometer for 50090 29 AI990 Compressor Parts for 50090 48 AF090 K Stri...

Page 17: ...17 Electrical Schematics Model PT CN 1524 S HC 50089...

Page 18: ...18 Electrical Schematics Model PT CN 1778 S HC 50090...

Page 19: ...ter online by visiting OMCAN PRODUCT WARRANTY REGISTRATION 3115 Pepper Mill Court Mississauga Ontario Canada L5L 4X5 https omcan com warranty registration or email to service omcan com Purchaser s Inf...

Page 20: ...relations avec nos clients et les fabricants de valeur Aujourd hui avec des partenaires en Am rique du Nord Europe Asie et Am rique du Sud nous travaillons continuellement am liorer et d velopper l e...

Reviews: