background image

103

 

(

diam.) x 48 (height) mm

Alarm LED

/

to external LED driver 

o

0.120dB/m and 60  C 

IP44

A2S

o

-10 to 60  C

Up to 95% 

2 years

1

6

0gr.

TECHNICAL CHARACTERISTICS

IDLE STATE POWER CONSUMPTION

ALARM POWER CONSUMPTION

SENSITIVITY

PRODUCED IN ACCORDANCE WITH

OPERATION TEMPERATURE RANGE

DEGREES OF COVER PROTECTION

OPERATION VOLTAGE

RELATIVE HUMIDITY

TYPICAL WEIGHT 

EXTERNAL DIMENSIONS 

GUARANTEE

INDICATORS

/

OUTPUT

CLASS

21-28V DC

1

.

5 mA (

with indication 

LED 

activated

)

1mA

ΕΝ 54-5, 

EN 54-7, IEC 60092-504, IEC 60533

 BSR-6057/A/MAR

ADDRESSABLE OPTICAL SMOKE 

AND THERMAL DETECTOR

GENERAL

Before  installing  the  detector,  the  user  must  read  these  instructions 
carefully and store this manual for future  reference.

 

BSR-6057/A/MAR 

is  used  on  ships  and  is  an  addressable  optical  smoke  and  thermal 
detector. It co-operates with 

BSR-

2

1

04/MAR,

 BSR-21

14/MAR panels. 

The device transmits an analogue value to the panel which  depends 
on the amount of the smoke that there is in the area. The analogue 
value is 100 with obscuration rate 0.120dB/m (small amount of smoke).

 

The factory setting of  the panel is to issue an alarm when the  analogue 
value is greater than 110.

 

The user can change from the panel this 

analogue value from 100 (high sensitivity) up to 120 (low sensitivity).

 

At 

o

the temperature of 

60 

C the thermal detector is activated and gives an 

120 value.

 

They have two parts, one plastic base which is installed on 

the ceiling and the main unit of the detector which is fastened to the 
base by a simple turning to the right.

 

The detectors have an  indication 

led which lights continuously in case of fire detection until there is a 
reset  signal  from  the  panel. 

 

When  we  silence  the  sirens  the  LED 

remains lit to show us the detector that issued the alarm. The LED goes 
off when we RESET the panel. The indication led also flashes every 8 
sec to indicate good operation.

To set each detector’s address you have to use the device BSR-2143

 

photo

.  1

.  (refer  to  it’s  instruction  manual). After  the  address  setting   

mark  this  number  to  the  sticker  on  the  detector’s  base 

(

ADR:XXX)

.

 

Each detector must have an address with which it is recognized from 
the panel. It`s forbidden for two devices with same addresses to be 
connected  to  the  same  loop.
 

 

OPERATION CHECK 

The  operation  check  can  be  done  by  spraying  a    small  amount  of 
smoke into the detector’s chamber.

 

You can use the special  smoke 

device  A-752  of  our  company,  or  a  similar  device.  It  is  advised  to 
conduct  a  good  operation  test  every  6  months  and  every  time  the 
detector  position is changed. It is essential to have good air circulation 
inside the detector. Therefore care must be taken so  that the vents of 
the detector are not covered. 

NOTE

The detectors must be placed in the ceiling on visible areas with no side 
obstacles  and  away  from  sides  with  no  air  circulation  or  strong  air 

2     

currents  and  vapors.  Each  detector  covers  almost  50  m

and  the 

distance  between  two  detectors  must  not  exceed  15m.  Also  the 
detectors must be placed away from fluorescent tubes at least 

50 

cm

.

 

2

The cables cross section must be from

 

0.5 to

 

1.5mm . 

ATTENTION

!!

After the device is  installed, care must be  taken, so that the detector 
vents are not blocked by  anything (i.e. dust, paint). Failing to do  so will 

ADDRESS SETTING

prevent the smoke particles to enter  the  detection  chamber.

After the installation, it is the sole responsibility of the user to 
maintain the detector  for  good  operation.

921605702_09_003

Page 

1

 from

 3

Thank you for your trust in our products  

Olympia Electronics -  European manufacturer

Reviews: