background image

103 (diam.) x 48 (height) mm

Alarm LED 

to external LED driver

0.120dB/m

IP44

EN 54-7, IEC 60092-504, IEC 60533

o

-10 to 60  C

Up to 95% 

2 years

160gr.

TECHNICAL CHARACTERISTICS

IDLE STATE POWER CONSUMPTION

ALARM POWER CONSUMPTION

SENSITIVITY

PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE

DEGREES OF COVER PROTECTION

OPERATION VOLTAGE

RELATIVE HUMIDITY

TYPICAL WEIGHT 

EXTERNAL DIMENSIONS 

GUARANTEE

INDICATORS

OUTPUT

21-28V DC

1.5 mA (with indication LED activated)

1mA

GENERAL

Before  installing  the  detector,  the  user  must 
read these instructions carefully and store this 
manual for future reference. BSR-6055/A/MAR 
is used on ships and is an addressable optical 
smoke  detector.  It  co-operates  with  BSR-
2104/MAR,  BSR-2114/MAR  panels.  The 
device  transmits  an  analogue  value  to  the 
panel  which    depends  on  the  amount  of  the 
smoke that there is in the area. The analogue 
value is 100 with obscuration rate 0.120dB/m 
(small amount of smoke). The factory setting of  
the  panel  is  to  issue  an  alarm  when  the   
analogue  value  is  greater  than  110.

The  user 

can change from the panel this analogue value 
from  100  (high  sensitivity)  up  to  120  (low 
sensitivity).

  They  have  two  parts,  one  plastic 

base which is installed on the ceiling and the 
main unit of the detector which is fastened to 
the base by a simple turning to the right. The 
detectors have an   indication   led which lights 
continuously in case of fire detection until there 
is  a  reset  signal  from  the  panel.    When  we 
silence the sirens the LED remains lit to show 
us the detector that issued the alarm. The LED 
goes  off  when  we  RESET  the  panel.  The 
indication  led  also  flashes  every  8  sec  to 
indicate good operation.

ADDRESS SETTING

To set each detector’s address you have to use 
the  device  BSR-2143  photo.  1.  (refer  to  it’s 
instruction  manual). After  the  address  setting   
mark  this  number  to  the  sticker  on  the 
detector’s  base  (ADR:XXX).  Each  detector 
must  have  an  address  with  which  it  is 

recognized from the panel. It is forbidden for two 
devices with same addresses to be connected   
on  the  same  loop.  

OPERATION CHECK 

The operation check can be done by spraying a  
small  amount  of  smoke  into  the  detector’s 
chamber. You can use the special smoke device 
A-752 of our company, or a similar device. It is 
advised to conduct a good operation test every 6 
months and every time the detector’s position is 
changed.  It  is  essential  to  exist  good  air 
circulation  inside  the  detector.  Therefore  care 
must be taken so that the vents of the detector 
are not covered. 

NOTE

The detectors must be placed on the ceiling on 
visible areas with no side obstacles and away 
from  sides  with  no  air  circulation  or  strong  air 
currents  and  vapors.  Each  detector  covers 

almost  50  m and  the  distance  between  two 
detectors  must  not  exceed  15m.  Also  the 
detectors must be placed away from fluorescent 
tubes at least 50cm. The cables cross section 

2

must be from 0.5 to 1.5mm . 

ATTENTION!!

After the device is installed, care must be  taken, 
so  that  the  detector  vents  are  not  blocked  by   
anything  (i.e.  dust,  paint).  Failing  to do  so  will 
prevent  the  smoke  particles  to  enter  the   
detection  chamber.

 
After the installation, it is the sole responsibility 
of  the  user  to  maintain  the  detector  for  good   
operation.

921605504_09_002

                         ADDRESSABLE OPTICAL SMOKE DETECTOR

 BSR-6055/A/MAR

Page 1 of 3