background image

UTP Video Trans12VDC Converter

Model NV-226J-PV Installation Manual

1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with a dry cloth.
7) Do not block any ventilation openings.
8) Install in accordance with the manufacturer’s instructions.
9) Do not install near any heat sources such as radiators, heat reg-
isters,  stoves  or  other  apparatus  (including  DVRs)  that  produce
heat.
10)  Do not defeat the safety purpose of the polarized or grounding-
type plug. A polarized plug has two blades with one wider than the
other. A grounding type plug has two blades and a third grounding
prong. The wider blade or the third prong are provided for your safe-
ty. If the provided plug does not fit into your outlet, consult an elec-
trician for replacement of the obsolete outlet.
11)  Protect the power cord from being walked on or pinched partic-
ularly at plugs, convenience receptacles, and the point where they
exit from the apparatus.
12)  Only use attachments/accessories specified by the manufacturer.
13)  Use only with cart, stand, tripod, bracket, or table specified by
the manufacturer, or sold with the apparatus. When a cart is used,
use caution when moving the cart/apparatus combination to avoid
injury from tipover.
14) Unplug this apparatus during lightning storms or when unused
for long periods of time.
15) Refer all servicing to qualified service personnel. Servicing is
required when the apparatus has been damaged in any way, such
as a power supply cord or plug is damaged, liquid has been spilled,
or objects have fallen into the apparatus, the apparatus has been
exposed to rain or moisture, does not operate normally, or has been
dropped.

This installation should be made by a qualified service 

person and should conform to all local codes.

WARNING - Do not install the unit in an environment 

where the operating ambient temperature exceeds 

167° F (75° C). The ventilation should not be impeded by

TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO
NOT REMOVE COVER OR BACK.  NO USER SERV-
ICEABLE PARTS INSIDE.  REFER SERVICING TO
QUALIFIED SERVICE PERSONNEL.

WARNING: TO REDUCE THE RISK OF ELECTRICAL
SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN
OR MOISTURE.

IMPORTANT SAFETY INSTRUCTIONS

The  NVT  UTP  Video  Transmitter  +12VDC
Converter combines a passive video transmitter
with a 24VAC-to-12VDC switching power supply.
When  used  with  an  NVT  Power  Supply  Cable
Integrator, cameras may be located at substan-
tial  distances,  yet  powered  from  the  control
room.  Unlike  conventional  CCTV  installations  or
power-over-ethernet  IP-based  video,  this  archi-
tecture  requires  no  intermediate  equipment  in
closets, and allows the entire system to be pow-
ered  by  a  single  control-room  resident  uninter-
ruptible power supply, if required.

Designed  as  part  of  NVT’s  PVD™  system,  the 
NV-226J-PV  UTP  Video  Transmitter  +12VDC
Converter  supports  fixed  12VDC  cameras  that
draw up to 400 mA (4.8 Watts) using standard 4-
pair  RJ45  EIA/TIA  568B  compliant  premises
wiring and pinouts. 

Wire Type

The  PVD  system  operates  well  with  Category
Unshielded Twisted-Pair  (UTP)  wire,  24-22 AWG
(0,5-0,6mm). NVT signals may reside near elec-
tromagnetic  fields  (in  accordance  with  National

Electrical  Code,  and  other  local  safety  require-
ments.)

Low  voltage  camera  power  video  may  be  sent
within same wire bundle.

Do NOT use shielded twisted-pair wire unless it
is Category rated. Multi-pair wire with an overall
shield (6 or more pairs) is OK.

Do NOT use un-twisted wire.

Wire  in  underground  conduit  or  wet  locations
must be polyethylene-jacketed, gel-filled.

Do  not  run  24/28 VAC  within  same  wire  bundle
with telecom or other datacom signals.

NVT  recommends  the  use  of  factory-crimped
RJ45  patch  cables  rather  than  unreliable  field-
crimped  RJ45s  to  connect  between  the  NVT
device and an adjacent female RJ45 jack.

Wire Distance

It  is  recommended  that  the  wire  distance  be
measured to ensure that it does not exceed the
maximum allowable distance. All measured dis-
tances include any coax in the path.

Wire resistance may be measured with an ohm-
meter by shorting the two conductors together at
the  far  end,  and  measuring  the  loop-resistance
out and back

Loop Resistance per 1000ft (300m)

24 AWG

(0,53 mm)

=

52 ohms

23 AWG 

(0,57 mm)

=

42 ohms

22 AWG

(0,64 mm)

=

33 ohms

20 AWG

(0,81 mm)

=

21 ohms

19 AWG

(0,91 mm)  

=

16 ohms

18 AWG

(1,02 mm)

=

13 ohms

Wire distances are limited as shown in the Wire
Distance Guide on back page.

covering the ventilation openings with items, such as news-

papers, table-cloths, curtains, etc. No naked flame 

sources, such as lighted candles should be placed on the

apparatus.

WARNING - Do not interconnect multiple 

outputs.

WARNING - The apparatus shall not be exposed 

to dripping or splashing and no objects filled with liquids,

such as vases, shall be placed o the apparatus.

WARNING - Use only a Certified power cord and 

plug (coupler / mains) assemblies for location 

installed.

WARNING - Power cord is regarded as main 

disconnect.

WARNING - The appliance coupler (power 

cord/mains) shall remain readily operable.

WARNING - For safety, never put NVT signals in 

the same conduit as high-voltage wiring.

WARNING - Do not restrict airflow around any 

active powered NVT products.