ZigBee

TM

-Power Socket with Power Consumption Monitoring

User Manual

Dimmable Socket with Power Detection

Model: Z809B

Energy Consumption Monitoring Series

For Home Automation

20150105
FW V5.0
HW V1.3

Summary of Contents for Z809B

Page 1: ...ZigBeeTM Power Socket with Power Consumption Monitoring User Manual Dimmable Socket with Power Detection Model Z809B Energy Consumption Monitoring Series For Home Automation 20150105 FW V5 0 HW V1 3 ...

Page 2: ...d devices Switch controller Simple controller Z501 series Multiple Scene controller Z503 Wall switch ZB02 series Light sensing switch Z302B On Off Status Indicator red green Button switch Network Indicator red green Binding key ...

Page 3: ...oth ZigBee is based on IEEE802 15 4 standard the mutual co ordination between thousands of sensors to exchange data Sensor to sensor or node to node communication is achieved through relays of control data between devices with only a fraction of energy use which denoted for highly transmission efficiency Note Wireless communication in some real use cases can be limited by the signal blockage Pleas...

Page 4: ...al Operation Make sure you have detached any home appliance from Z809B And also restore the device back to its factory default setting Refer to Restore to factory setting section Step 1 Make sure you have open up permit join function valid for 60 seconds of a coordinator or a router Step 2 Now plug in Z809B into AC power socket to power it Z809B device will start to search for the network within r...

Page 5: ...l switch to exchange binding according to the instructions of that device 3 When binding is successful the green indicator on Z809B will flash 5 times then return to solid lit If successful you should be able to wireless control Z809B Otherwise it flashes quickly 10 times indicating pairing unsuccessful Clear pairing setting You may remove the pairing between the two or more devices Unbinding proc...

Page 6: ...09B will stay Off This is to prevent from accidental turning the device on Manual switch When the button switch is pressed Z809B increases the output by 1 8th As you keep pressing until it passes the brightest Z809B will decrement the output until its output is totally turned off The On Off status indicator turns red when the output is totally Off or green when output is On Absent of Coordinator I...

Page 7: ...ger Ensure that you go through Consumption reporting and also Configure reporting time interval described in ZiG BUTLER page otherwise Z809B will not sent consumption reading properly when misconfigured Z809B can report the consumption reading to Netvox s ZiG BUTLER or to any 3rd party in home display If target device pairing is not done refer to Consumption reporting in ZiG BUTLER section Z809B w...

Page 8: ...to join to a new network by simply reset the device to restore to the factory setting notes restore Z809B back to factory default will not reset power consumption summation Please refer to Resetting Power Consumption Summation section above Operation 1 While the device is given power hold press the binding key for 15 seconds then release the key when the green network indicator flashes 3 times the...

Page 9: ...hen 10 flashes if successful Permit Join Short press binding key once Flashes 60 times in 60 seconds Resetting power consumption summation Hold press binding key 20s then within 2s short press test button once 4 flashes hold press binding key 1 flash test button once Device Pairing Hold press binding key 3s 1 flash hold press binding key 5 flashes if successful otherwise flashes quickly 10 times ...

Page 10: ...t a waterproof product use it indoor only 4 Load Protection The current is over 3A it will be off load in 2 seconds 5 After it is off load the Bit1 Current OverLoad of the parameter ACAlarmsMask will be checked Bit1 Current OverLoad is 1 it sends the alarm message Bit1 Current OverLoad is 0 it doesn t send the alarm message When it sends the alarm message AlarmCluster 0x0B04 AlarmCode 0xF0 indicat...

Page 11: ... 0x03 M 0x0001 ApplicationVersion 8 bit Unsigned integer 0x00 0xff Read only 0x32 O 0x0002 StackVersion 8 bit Unsigned integer 0x00 0xff Read only 0x35 O 0x0003 HWVersion 8 bit Unsigned integer 0x00 0xff Read only 0x0D O Cluster ID for Z809B Server side Client side EP 0x01 Device ID Dimmer Light 0x0101 Basic 0x0000 None Identify 0x0003 Groups 0x0004 Scenes 0x0005 On Off 0x0006 Level Control 0x0008...

Page 12: ...dentifier Character string 0 32bytes Read only Z809BE 3R O 0x0006 DateCode Character string 0 16 bytes Read only 2014112 1 O 0x0007 PowerSource 8 bit Enumeration 0x00 0xff Read only 0x01 M Attributes of the Group server cluster Identifier Name Type Range Access Default Mandatory Optional 0x0000 NameSupport 8 bit bitmap 10000000 Read Only 0x80 M ...

Page 13: ...t use or store the device in a very cold place than the suggested minimum temperature The water can be condensed inside the device when moving to an area that is higher in temperature This can severely damage the PCB board and circuitry This may shorten the life span of the device damage the battery and cause the housing to deform Do not throw or strongly vibrate the device This may damage connect...